Paramedic rhythm interpretation misclassification is associated with poor survival from out-of- hospital cardiac arrest

被引:2
作者
Stoecklein, H. Hill [1 ,2 ]
Pugh, Andrew [1 ]
Johnson, M. Austin [1 ]
Tonna, Joseph E. [1 ]
Stroud, Michael [2 ]
Drakos, Stavros [3 ,4 ]
Youngquist, Scott T. [1 ,2 ]
机构
[1] Univ Utah, Sch Med, Div Emergency Med, Salt Lake City, UT USA
[2] Salt Lake City Fire Dept, Salt Lake City, UT USA
[3] Univ Utah, Sch Med, Div Cardiol, Salt Lake City, UT USA
[4] Nora Eccles Harrison Cardiovasc Res & Training In, Salt Lake City, UT USA
基金
美国国家卫生研究院;
关键词
Cardiac arrest; Shock accuracy; Defibrillation; Ventricular fibrillation; Ventricular; Tachycardia; AMERICAN-HEART-ASSOCIATION; CHEST COMPRESSION; CARDIOPULMONARY-RESUSCITATION; EXTERNAL DEFIBRILLATORS; HEALTH-PROFESSIONALS; CARE COMMITTEE; TASK-FORCE; STATEMENT; SUBCOMMITTEE; PERFORMANCE;
D O I
10.1016/j.resuscitation.2021.12.016
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Early recognition and rapid defibrillation of shockable rhythms is strongly associated with survival in out of hospital cardiac arrest (OHCA). Little is known about the accuracy of paramedic rhythm interpretation and its impact on survival. We hypothesized that inaccurate paramedic interpretation of initial rhythm would be associated with worse survival. Methods: This is a retrospective cohort analysis of prospectively collected OHCA data over a nine-year period within a single, urban, fire-based EMS system that utilizes manual defibrillators equipped with rhythm-filtering technology. We compared paramedic-documented initial rhythm with a reference standard of post-event physician interpretation to estimate sensitivity and specificity of paramedic identification of and shock delivery to shockable rhythms. We assessed the association between misclassification of initial rhythm and neurologically intact survival to hospital discharge using multivariable logistic regression. Results: A total of 863 OHCA cases were available for analysis with 1,756 shocks delivered during 542 (63%) resuscitation attempts. Eleven percent of shocks were delivered to pulseless electrical activity (PEA). Sensitivity and specificity for paramedic initial rhythm interpretation were 176/197 (0.89, 95% CI 0.84-0.93) and 463/504 (0.92, 95% CI 0.89-0.94) respectively. No patient survived to hospital discharge when paramedics misclassified the initial rhythm. Conclusions: Paramedics achieved high sensitivity for shock delivery to shockable rhythms, but with an 11% shock delivery rate to PEA. Misclassification of initial rhythm was associated with poor survival. Technologies that assist in rhythm identification during CPR, rapid shock delivery, and minimal hands-o time may improve outcomes.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 33 条
  • [1] A Reliable Method for Rhythm Analysis during Cardiopulmonary Resuscitation
    Ayala, U.
    Irusta, U.
    Ruiz, J.
    Eftestol, T.
    Kramer-Johansen, J.
    Alonso-Atienza, F.
    Alonso, E.
    Gonzalez-Otero, D.
    [J]. BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [2] Analyzing cardiac rhythm in the presence of chest compression artifact for automated shock advisory
    Babaeizadeh, Saeed
    Firoozabadi, Reza
    Han, Chengzong
    Helfenbein, Eric D.
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (06) : 798 - 803
  • [4] Global incidences of out-of-hospital cardiac arrest and survival rates: Systematic review of 67 prospective studies
    Berdowski, Jocelyn
    Berg, Robert A.
    Tijssen, Jan G. P.
    Koster, Rudolph W.
    [J]. RESUSCITATION, 2010, 81 (11) : 1479 - 1487
  • [5] Delays in Cardiopulmonary Resuscitation, Defibrillation, and Epinephrine Administration All Decrease Survival in In-hospital Cardiac Arrest
    Bircher, Nicholas G.
    Chan, Paul S.
    Xu, Yan
    Faillace, Robert T.
    Mancini, Mary E.
    Berg, Robert A.
    Allen, Emilie
    Hunt, Elizabeth A.
    Nadkarni, Vinay M.
    Peberdy, Mary Ann
    Ornato, Joseph P.
    Braithwaite, Scott
    Nichol, Graham
    Warren, Samuel
    Duncan, Kathy
    LaBresh, Kenneth
    Sasson, Comilla
    Knight, Lynda
    Donnino, Michael W.
    Smyth, Mindy
    Eigel, Brian
    Gent, Lana
    Mader, Timothy J.
    Kern, Karl B.
    Geocadin, Romergryko G.
    [J]. ANESTHESIOLOGY, 2019, 130 (03) : 414 - 422
  • [6] Association Between Chest Compression Interruptions and Clinical Outcomes of Ventricular Fibrillation Out-of-Hospital Cardiac Arrest
    Brouwer, Tom F.
    Walker, Robert G.
    Chapman, Fred W.
    Koster, Rudolph W.
    [J]. CIRCULATION, 2015, 132 (11) : 1030 - 1037
  • [7] Inaccurate treatment decisions of automated external defibrillators used by emergency medical services personnel: Incidence, cause and impact on outcome
    Calle, Paul A.
    Mpotos, Nicolas
    Calle, Simon P.
    Monsieurs, Koenraad G.
    [J]. RESUSCITATION, 2015, 88 : 68 - 74
  • [8] Delayed time to defibrillation after in-hospital cardiac arrest
    Chan, Paul S.
    Krumholz, Harlan M.
    Nichol, Graham
    Nallamothu, Brahmajee K.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (01) : 9 - 17
  • [9] CUMMINS RO, 1984, LANCET, V2, P318
  • [10] IMPROVING SURVIVAL FROM SUDDEN CARDIAC-ARREST - THE CHAIN OF SURVIVAL CONCEPT - A STATEMENT FOR HEALTH-PROFESSIONALS FROM THE ADVANCED CARDIAC LIFE-SUPPORT SUBCOMMITTEE AND THE EMERGENCY CARDIAC CARE COMMITTEE, AMERICAN-HEART-ASSOCIATION
    CUMMINS, RO
    ORNATO, JP
    THIES, WH
    PEPE, PE
    BILLI, JE
    SEIDEL, J
    JAFFE, AS
    FLINT, LS
    GOLDSTEIN, S
    ABRAMSON, NS
    BROWN, C
    CHANDRA, NC
    GONZALEZ, ER
    NEWELL, L
    STULTS, KR
    MEMBRINO, GE
    [J]. CIRCULATION, 1991, 83 (05) : 1832 - 1847