X-Ray Response of a Transition Edge Sensor Microcalorimeter With a Mushroom-Shaped Absorber

被引:0
作者
Ezaki, S. [1 ]
Maehata, K. [1 ]
Iyomoto, N. [1 ]
Maeda, M. [1 ]
Hara, T. [2 ]
Mitsuda, K. [3 ]
Tanaka, K. [4 ]
机构
[1] Kyushu Univ, Dept Appl Quantum Phys & Nucl Engn, Fukuoka 8190395, Japan
[2] Natl Inst Mat Sci, Tsukuba, Ibaraki 3050044, Japan
[3] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Sagamihara, Kanagawa 2525210, Japan
[4] Hitachi High Tech Sci Corp, Shizuoka 4101393, Japan
基金
日本科学技术振兴机构;
关键词
Microcalorimeter; superconducting devices; superconducting transition edge sensor (TES); X-ray absorber;
D O I
10.1109/TASC.2014.2377113
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Superconducting transition edge sensor (TES) microcalorimeters are excellent energy-resolving devices for X-ray detection. We fabricated two types of TES microcalorimeter using different mushroom-shaped absorber thicknesses (0.5 and 5 mu m). Both types of TES microcalorimeter were irradiated with X-ray photons emitted by an Fe-55 source. X-ray detection signal pulses were collected to examine the effects of absorber thickness on performance. The values of the thermal conductance G were obtained by analyzing the current-voltage characteristics of the TES. By comparing the experimental G for both types of TES microcalorimeter, the absorber thickness was found to not affect the thermal properties of either type of TES microcalorimeter. The sensitivity alpha values for both TES microcalorimeters were obtained by analyzing the decay time constant of the X-ray detection signal pulses. The experimental ratio of the full-width at half-maximum value for the energy peaks of the Mn-K-alpha X-ray between both types of TES microcalorimeter was similar to theoretical estimations based on the different absorber thicknesses.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 50 条
[31]   Characterizations of the electrothermal parameters of a transition edge sensor microcalorimeter and its energy resolution [J].
Zhao, Yue ;
Wang, Hubing ;
Gao, Bo ;
Wang, Zhen .
SUPERCONDUCTIVITY, 2023, 7
[32]   On Low-Energy Tail Distortions in the Detector Response Function of X-Ray Microcalorimeter Spectrometers [J].
O'Neil, G. C. ;
Szypryt, P. ;
Takacs, E. ;
Tan, J. N. ;
Buechele, S. W. ;
Naing, A. S. ;
Joe, Y. I. ;
Swetz, D. ;
Schmidt, D. R. ;
Doriese, W. B. ;
Gard, J. D. ;
Reintsema, C. D. ;
Ullom, J. N. ;
Villarrubia, J. S. ;
Ralchenko, Yu. .
JOURNAL OF LOW TEMPERATURE PHYSICS, 2020, 199 (3-4) :1046-1054
[33]   Multitone harmonic-balance simulations of an x-ray transition-edge sensor characterized at BESSY II [J].
Rostem, K. ;
Goldie, D. J. ;
Withington, S. ;
Hoevers, H. F. C. ;
Gottardi, L. ;
van der Kuur, J. .
JOURNAL OF APPLIED PHYSICS, 2010, 108 (02)
[34]   Processing pulses from TES microcalorimeter X-ray detectors [J].
Thurgate, Stephen ;
Jach, Terrence .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1014
[35]   High aspect ratio transition edge sensors for x-ray spectrometry [J].
de Wit, M. ;
Gottardi, L. ;
Taralli, E. ;
Nagayoshi, K. ;
Ridder, M. L. ;
Akamatsu, H. ;
Bruijn, M. P. ;
D'Andrea, M. ;
van der Kuur, J. ;
Ravensberg, K. ;
Vaccaro, D. ;
Visser, S. ;
Gao, J. R. ;
den Herder, J-W A. .
JOURNAL OF APPLIED PHYSICS, 2020, 128 (22)
[36]   Development of an array of transition edge sensors for application in X-ray astronomy [J].
Bruijn, MP ;
Baars, NHR ;
Tiest, WMB ;
Germeau, A ;
Hoevers, HFC ;
de Korte, PAJ ;
Mels, WA ;
Ridder, ML ;
Krouwer, E ;
van Baar, JJ ;
Wiegerink, RJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3) :443-445
[37]   Development of arrays of transition edge sensors for application in X-ray astronomy [J].
Bruijn, MP ;
Tiest, WMB ;
Hoevers, HFC ;
Krouwer, E ;
van der Kuur, J ;
Ridder, ML ;
Moktadir, Z ;
Wiegerink, R ;
van Gelder, D ;
Elwenspoek, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2) :143-146
[38]   Towards a cryogenic imaging array of transition edge X-ray microcalorimeters [J].
Bruijn, MP ;
Tiest, WB ;
Hoevers, HFC ;
van der Kuur, J ;
Mels, WA ;
de Korte, PAJ .
X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 :145-153
[39]   Performance of a Broad-Band, High-Resolution, Transition-Edge Sensor Spectrometer for X-ray Astrophysics [J].
Smith, Stephen J. ;
Adams, Joseph S. ;
Bandler, Simon R. ;
Beaumont, Sophie ;
Chervenak, James A. ;
Denison, Edward, V ;
Doriese, William B. ;
Durkin, Malcolm ;
Finkbeiner, Fred M. ;
Fowler, Joseph W. ;
Hilton, Gene C. ;
Hummatov, Ruslan ;
Irwin, Kent D. ;
Kelley, Richard L. ;
Kilbourne, Caroline A. ;
Leutenegger, Maurice A. ;
Miniussi, Antoine R. ;
Porter, Frederick S. ;
Reintsema, Carl D. ;
Sadleir, John E. ;
Sakai, Kazuhiro ;
Swetz, Daniel S. ;
Ullom, Joel N. ;
Vale, Leila R. ;
Wakeham, Nicholas A. ;
Wassell, Edward J. ;
Witthoeft, Michael C. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (05)
[40]   Development of the microcalorimeter detector for the Athena/X-ray Integral Field Unit [J].
Smith, Stephen J. ;
Adams, Joseph S. ;
Bandler, Simon R. ;
Borrelli, Rachel B. ;
Chervenak, James A. ;
Colazo-Petit, Felipe A. ;
Cumbee, Renata S. ;
Finkbeiner, Fred M. ;
Fuhrman, Joshua D. ;
Hull, Samuel, V ;
Kelley, Richard L. ;
Kilbourne, Caroline A. ;
Porter, F. Scott ;
Rani, Asha ;
Sakai, Kazuhiro ;
Wakeham, Nicholas A. ;
Wassell, Edward J. ;
Witthoeft, Michael C. ;
Yoon, Sang H. .
SPACE TELESCOPES AND INSTRUMENTATION 2024: ULTRAVIOLET TO GAMMA RAY, PT 1, 2024, 13093