Cardiac MR flowmetry: Experimental validation and results in patients with operated cardiac deficiencies

被引:8
作者
Hosten, N
Gutberlet, M
Kuhne, T
Oellinger, H
Vogel, M
Bockel, T
Bock, J
Frank, J
机构
[1] Humboldt Univ, Klinikum Rudolf Virchow, Strahlenklin & Poliklin, D-13353 Berlin, Germany
[2] Deutsch Herzzentrum Berlin, Abt Angeborene Herzfehler Kinderkardiol, Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1998年 / 168卷 / 05期
关键词
heart; MR; flow dynamics; valves and prostheses; vascular studies;
D O I
10.1055/s-2007-1015165
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A flow-sensitive MR sequence (phase-contrast technique) was evaluated in phantom studies with regard to factors influencing measurements and correctness of results. The sequence was additionally used for functional evaluation of operated congenital heart disease. Methods: Pulsatile and constant flow were produced with the help of a phantom. Influence of angulation, range and vessel bending was evaluated. An examination protocol was developed from the results. 35 patients with surgically repaired congenital heart disease or without repair were examined. Results: A range preset below the actual flow velocity as well as angulation of more than 20 degrees were isolated as main pitfalls in MR flowmetry. In addition to morphological MR findings flow measurements were possible in 11 patients at vessel sites which were not or not completely suited for examination by Doppler ultrasound. Conclusion: The evaluated phase-contrast technique allows for fast and reliable flow quantification if the influences identified in phantom studies are considered.
引用
收藏
页码:480 / 487
页数:8
相关论文
共 15 条
[1]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[2]   EVALUATION OF ULTRAFAST PHASE-CONTRAST IMAGING IN THE THORACIC AORTA [J].
DEBATIN, JF ;
DAVIS, CP ;
FELBLINGER, J ;
MCKINNON, GC .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1995, 3 (02) :59-66
[3]   AORTIC-VALVE PRESSURE-GRADIENTS IN PATIENTS WITH AORTIC-VALVE STENOSIS - QUANTIFICATION WITH VELOCITY-ENCODED CINE MR IMAGING [J].
EICHENBERGER, AC ;
JENNI, R ;
VONSCHULTHESS, GK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) :971-977
[4]   MAGNETIC-RESONANCE-IMAGING OF BLOOD-FLOW WITH A PHASE SUBTRACTION TECHNIQUE - INVITRO AND INVIVO VALIDATION [J].
EVANS, AJ ;
IWAI, F ;
GRIST, TA ;
SOSTMAN, HD ;
HEDLUND, LW ;
SPRITZER, CE ;
NEGROVILAR, R ;
BEAM, CA ;
PELC, NJ .
INVESTIGATIVE RADIOLOGY, 1993, 28 (02) :109-115
[5]   THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT [J].
FIRMIN, DN ;
NAYLER, GL ;
KILNER, PJ ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :230-241
[6]   AORTIC REGURGITATION - QUANTITATION WITH MR IMAGING VELOCITY MAPPING [J].
HONDA, N ;
MACHIDA, K ;
HASHIMOTO, M ;
MAMIYA, T ;
TAKAHASHI, T ;
KAMANO, T ;
KASHIMADA, A ;
INOUE, Y ;
TANAKA, S ;
YOSHIMOTO, N ;
MATSUO, H .
RADIOLOGY, 1993, 186 (01) :189-194
[7]   QUANTITATION OF CARDIAC-OUTPUT WITH VELOCITY-ENCODED, PHASE-DIFFERENCE MAGNETIC-RESONANCE-IMAGING [J].
HUNDLEY, WG ;
LI, HF ;
HILLIS, LD ;
MESHACK, BM ;
LANGE, RA ;
WILLARD, JE ;
LANDAU, C ;
PESHOCK, RM .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (17) :1250-1255
[8]   ASSESSMENT OF LEFT-TO-RIGHT INTRACARDIAC SHUNTING BY VELOCITY-ENCODED, PHASE-DIFFERENCE MAGNETIC-RESONANCE-IMAGING - A COMPARISON WITH OXIMETRIC AND INDICATOR DILUTION TECHNIQUES [J].
HUNDLEY, WG ;
LI, HF ;
LANGE, RA ;
PFEIFER, DP ;
MESHACK, BM ;
WILLARD, JE ;
LANDAU, C ;
WILLETT, D ;
HILLIS, LD ;
PESHOCK, RM .
CIRCULATION, 1995, 91 (12) :2955-2960
[9]   MAGNETIC-RESONANCE JET VELOCITY MAPPING IN MITRAL AND AORTIC-VALVE STENOSIS [J].
KILNER, PJ ;
MANZARA, CC ;
MOHIADDIN, RH ;
PENNELL, DJ ;
SUTTON, MGS ;
FIRMIN, DN ;
UNDERWOOD, SR ;
LONGMORE, DB .
CIRCULATION, 1993, 87 (04) :1239-1248
[10]   VALVE AND GREAT VESSEL STENOSIS - ASSESSMENT WITH MR JET VELOCITY MAPPING [J].
KILNER, PJ ;
FIRMIN, DN ;
REES, RSO ;
MARTINEZ, J ;
PENNELL, DJ ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
LONGMORE, DB .
RADIOLOGY, 1991, 178 (01) :229-235