Seismic collapse assessment of steel plate shear walls considering the mainshock-aftershock effects

被引:19
作者
Jalali, Seyed Alireza [1 ]
Amini, Ali [2 ]
Mansouri, Iman [3 ]
Hu, Jong Wan [4 ,5 ]
机构
[1] Shahabdanesh Univ, Dept Civil Architectural & Mech Engn, Qom, Iran
[2] Amirkabir Univ Technol, Dept Civil & Environm Engn, Tehran, Iran
[3] Birjand Univ Technol, Dept Civil Engn, Birjand, Iran
[4] Incheon Natl Univ, Dept Civil & Environm Engn, Incheon 22012, South Korea
[5] Incheon Natl Univ, Incheon Disaster Prevent Res Ctr, Incheon, South Korea
关键词
Steel shear wall; Mainshock-aftershock sequence; Seismic-collapse capacity; Collapse mechanism; Inelastic deformation demand; OpenSees; PERFORMANCE EVALUATION; MULTIPLE EARTHQUAKES; NONLINEAR BEHAVIOR; DYNAMIC-ANALYSIS; FRAME BUILDINGS; SEQUENCE; DAMAGE; MODEL;
D O I
10.1016/j.jcsr.2021.106688
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study evaluates the effect of mainshock-aftershock sequences on the collapse of steel plate shear wall (SPSW) systems. For this purpose, three 9-, 14-and 20-story SPSWs are selected considering the practical range of heights used in this system. After numerical modeling of the structures, they are initially subjected to static-pushover analyses to evaluate their plastic behavior in large inelasticity regions. The incremental dynamic analysis is subsequently performed to capture the collapse capacity of the structures under aftershock excitations preceded by mainshocks that pose various levels of damage expressed in terms of maximum inter-story drift (MID). Evaluation of the median collapse capacities under aftershock excitations exhibit the same reduction ra -tios at similar mainshock MIDs for the different structures. This reduction is predicted via a quadratic polynomial for given mainshock MID values. Investigation of the mainshock-aftershock effects on distribution of the MIDs and maximum ductility demands at the collapse state shows that the prior mainshock damage mainly affects the collapse capacity by consuming the energy-absorption capacity of the infill plates, thus causing strength de-terioration. Irrespective of the mainshock damage level, the structures were found to collapse when their first-story columns reach a threshold softening level. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:14
相关论文
共 66 条
[1]  
Abdollahzadeh G, 2018, J EARTHQ ENG, P1
[2]   Cyclic behavior of moment frames with conventional or slit Infills [J].
Ahmadi, Zahra ;
Aghakouchak, Ali Akbar ;
Mirghaderi, Seyyed Rasoul .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 178
[3]   The effects of repeated earthquake ground motions on the non-linear response of SDOF systems [J].
Amadio, C ;
Fragiacomo, M ;
Rajgelj, S .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2003, 32 (02) :291-308
[4]  
[Anonymous], 2016, AISC 341-16 Seismic provisions for structural steel buildings
[5]  
[Anonymous], 2017, J EARTHQ ENG
[6]  
[Anonymous], 2016, ASCE 7 16 MINIMUM DE
[7]  
[Anonymous], 2009, FEMA P695
[8]  
Aschheim M., 1999, Earthquake Spectra, V15, P1, DOI [10.1193/1.1586026, DOI 10.1193/1.1586026]
[9]   A multi-modal-analysis-based simplified seismic design method for high-rise frame-steel plate shear wall dual structures [J].
Bai, Jiulin ;
Zhang, Jianyuan ;
Jin, Shuangshuang ;
Du, Ke ;
Wang, Yu-hang .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 177
[10]  
Beer M., 2021, COMPUT STRUCT, V2021, P242, DOI DOI 10.1016/J.COMPSTRUC.2020.106359