A steady-state and flow-through cell for screen-printed eight-electrode arrays

被引:15
作者
Dock, E
Christenson, A
Sapelnikova, S
Krejci, J
Emnéus, J
Ruzgas, T
机构
[1] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[2] BVT Technol AS, CZ-61700 Brno, Czech Republic
关键词
electrode array; steady-state measurements; screen-printed electrode; flow-through cell; biosensor array;
D O I
10.1016/j.aca.2004.10.090
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical cell has been developed enabling amperometric steady-state- and flow-injection measurements with screen-printed arrays consisting of eight working electrodes (circle divide = 1 mm) arranged radially around a printed Ag/AgCl reference electrode in the centre. The cell contained a rotator, providing similar hydrodynamics over all the working electrodes in the array, which was manually centered under the rotator. The reproducibility of steady-state measurements with eight-electrode platinum or gold arrays in this cell was studied by measuring and comparing currents from ferricyanide reduction at each electrode in the array. It was found that the relative standard deviation (R.S.D.) for the currents at different electrodes on one array was below 5%. Similar R.S.D. was found if measurements were compared between several arrays. This indicates that manual insertion/positioning of the eight-electrode array in the cell and hydrodynamics at the electrodes provided measurement reproducibility similar to the reproducibility of manufacturing eight-electrode platinum or gold arrays by screen-printing. A comparative study was performed between screen-printed and through mask sprayed carbon arrays. It was found that the reproducibility of the sprayed arrays was similar to that of the platinum or gold screen-printed arrays, with R.S.D. values below 6% regarding the variation between electrodes within the same array and the variation between different arrays. To enable flow-injection measurements, a tube (0.4 mm inner diameter) was inserted into a hole drilled through the centre of the steady-state cell rotator. This construction made it possible to inject the solution into the cell through the tube (not rotating), while the rotator was spinning over the eight-electrode array. It was found that this combination of flow-injection and mixing by a rotator provided a uniform current response over the array electrodes and that, at optimum conditions, the R.S.D. values between the eight electrodes in the array were nearly the same as in case of the steady-state measurements, i.e., below 5%. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:165 / 172
页数:8
相关论文
共 35 条
[1]   Configurations used in the design of screen-printed enzymatic biosensors.: A review [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) :153-163
[2]   Cross-reactive chemical sensor arrays [J].
Albert, KJ ;
Lewis, NS ;
Schauer, CL ;
Sotzing, GA ;
Stitzel, SE ;
Vaid, TP ;
Walt, DR .
CHEMICAL REVIEWS, 2000, 100 (07) :2595-2626
[3]  
Alexander PW, 1996, FIELD ANAL CHEM TECH, V1, P31
[4]  
[Anonymous], 2000, MULTIVARIATE DATA AN
[5]   Flow-through cell based on an array of gold microelectrodes obtained from modified integrated circuit chips [J].
Augelli, MA ;
Nascimento, VB ;
Pedrotti, JJ ;
Gutz, IGR ;
Angnes, L .
ANALYST, 1997, 122 (08) :843-847
[6]   SENSOR ARRAY FOR CARBOHYDRATES AND AMINO-ACIDS BASED ON ELECTROCATALYTIC MODIFIED ELECTRODES [J].
CHEN, Q ;
WANG, J ;
RAYSON, G ;
TIAN, BM ;
LIN, YH .
ANALYTICAL CHEMISTRY, 1993, 65 (03) :251-254
[7]   HYDRODYNAMIC PROPERTIES AND MASS-TRANSFER CHARACTERISTICS OF ELECTROCHEMICAL FLOW-THROUGH CELLS OF THE CONFINED WALL JET TYPE [J].
DALHUIJSEN, AJ ;
VANDERMEER, TH ;
HOOGENDOORN, CJ ;
HOOGVLIET, JC ;
VANBENNEKOM, WP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 182 (02) :295-313
[8]   Screen-printed carbon electrodes modified with cellobiose dehydrogenase: Amplification factor for catechol vs. reversibility of ferricyanide [J].
Dock, E ;
Ruzgas, T .
ELECTROANALYSIS, 2003, 15 (5-6) :492-498
[9]   Effect of interfering substances on current response of recombinant peroxidase and glucose oxidase- recombinant peroxidase modified graphite electrodes [J].
Dock, E ;
Lindgren, A ;
Ruzgas, T ;
Gorton, L .
ANALYST, 2001, 126 (11) :1929-1935
[10]  
F Allen J Bard L.R., 2001, Electrochemical Methods: Fundamentals and Applications