A nonparametric MRI inhomogeneity correction method

被引:52
作者
Manjon, Jose V.
Lull, Juan J.
Carbonell-Caballero, Jose
Garcia-Marti, Gracian
Marti-Bonmati, Luis
Robles, Montserrat
机构
[1] Univ Politecn Valencia, Bioengn Elect & Telemed Grp, ES-46022 Valencia, Spain
[2] Quiron Hosp, Dept Radiol, Valencia 46017, Spain
关键词
inhomogeneity correction; bias field; non-uniformity;
D O I
10.1016/j.media.2007.03.001
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Magnetic resonance images are commonly affected by intensity inhomogeneities which make it difficult to obtain any quantitative measures from them. We present a new method of automatically correcting this artifact using a nonparametric coarse to fine approach which allows bias fields to be modeled with different frequency ranges without user supervision. We also propose a new entropy-related cost function based on the combination of intensity and gradient image features for more robust homogeneity measurement. The proposed methodology has been evaluated for both synthetic and real data and compared with state of the art methods, showing the best results in the comparison. The proposed method is fully automatic and has no input parameters, making it very easy to use in a clinical environment. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:336 / 345
页数:10
相关论文
共 28 条
[1]  
Ahmed M. N., 1999, V1191, P1004
[2]   Qualitative and quantitative evaluation of six algorithms for correcting intensity nonuniformity effects [J].
Arnold, JB ;
Liow, JS ;
Schaper, KA ;
Stern, JJ ;
Sled, JG ;
Shattuck, DW ;
Worth, AJ ;
Cohen, MS ;
Leahy, RM ;
Mazziotta, JC ;
Rottenberg, DA .
NEUROIMAGE, 2001, 13 (05) :931-943
[3]   Voxel-based morphometry - The methods [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2000, 11 (06) :805-821
[4]   Unified segmentation [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2005, 26 (03) :839-851
[5]  
ASHBURNER J, 2002, ANOTHER MRI BIAS COR
[6]   TECHNICAL NOTE - INTENSITY CORRECTION IN SURFACE-COIL MR IMAGING [J].
AXEL, L ;
COSTANTINI, J ;
LISTERUD, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :418-420
[7]  
BELAROUSSI B, 2005, MED IMAGE ANAL, V10, P121
[8]  
Brechbuhler C, 1996, LECT NOTES COMPUT SC, V1131, P141, DOI 10.1007/BFb0046948
[9]   Design and construction of a realistic digital brain phantom [J].
Collins, DL ;
Zijdenbos, AP ;
Kollokian, V ;
Sled, JG ;
Kabani, NJ ;
Holmes, CJ ;
Evans, AC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (03) :463-468
[10]   CORRECTION OF INTENSITY VARIATIONS IN MR-IMAGES FOR COMPUTER-AIDED TISSUE CLASSIFICATION [J].
DAWANT, BM ;
ZIJDENBOS, AP ;
MARGOLIN, RA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) :770-781