Thioglycolic Acid-Functionalized Water-Soluble MoS2-Based Sensor for Toxic Ion Detection

被引:0
|
作者
Majumder, Santanab [1 ]
Sett, Avik [2 ]
Goswami, Dipak Kumar [3 ]
Bhattacharyya, Tarun Kanti [2 ]
机构
[1] Indian Inst Technol Kharagpur, Sch Nanosci & Technol, Kharagpur 721302, W Bengal, India
[2] Indian Inst Technol Kharagpur, Dept Elect & Elect Commun Engn, Kharagpur 721302, W Bengal, India
[3] Indian Inst Technol Kharagpur, Dept Phys, Kharagpur 721302, W Bengal, India
关键词
Mercury sensing; molybdenum disulfide (MoS2); nanoflakes; selectivity; thioglycolic acid (TGA); water dispersion; ROOM-TEMPERATURE; NANOPARTICLES;
D O I
10.1109/TED.2022.3193022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work demonstrates the implementation of thioglycolic acid (TGA) functionalized water-soluble NH2-molybdenum disulfide (MoS2) nanosheets as sensitive layers for toxic heavy metal ion sensing in drinking water. The sensor device was tested for several ions commonly found in drinking water, e.g., As (III), Pd (II), Hg (II), and Cd (II). When the sensor was exposed to individual ions, it showed negligible response toward elements such as As (III), Pd (II), and other commonly present metal ions. However, at 25 ppb, some cross sensitivity was observed between Cd (II) and Hg (II) ions. The mathematical analysis was performed to investigate the cross-sensitive behavior, and a model was put forward. It was evident from the higher attachment factor (N) for Cd concerning Hg (II), derived from the model which supported Cd's higher response when exposed individually (N-Cd = 4 x 10(16) cm(3)/ppb and N-Hg = 1.6 x 10(14) cm(3)/ppb). Furthermore, the band structure and electron concentration were plotted for individual Cd (II) and Hg (II) ions. Compared to Hg (II), Cd (II) efficiently depleted the amine-MoS2 and TGA junction. To better understand selectivity and response, the device was exposed to Cd (II) and Hg (II) ions simultaneously at different concentrations, which looked into the effect of the two interacting ions. A mathematical model was hence established. It was found that the absorption coefficient (K-Hg) was much higher (63 ppb(-1)) than Cd (K-Cd ) (0.38 ppb(-1)). The interaction factor (KHg-Cd), i.e., the absorption coefficient of Cd in the presence of Hg, was calculated as -0.086 ppb(-2), which is lower than KCd-Hg(-0.013 ppb(-2)), which indicated that Hg is more active toward adsorption in competition to the Cd ions. This competitive dominance for Hg (II) adsorption may be attributed to the affinity of thiol groups present in the TGA molecules for Hg (II) over Cd (II) ions. The device was repeatable after testing with five different devices with a standard deviation of Of 0.5322 and stable up to 50 days with +/- 3% response variation. Thus, the proposed sensor may be a suitable candidate for low-cost water quality monitors.
引用
收藏
页码:5193 / 5198
页数:6
相关论文
共 50 条
  • [21] A fluorescent sensor based on pentafluoropropanoic acid-functionalized UiO-66-NH2 for enhanced selectivity and sensitivity of dicloran detection
    Sun, Xueqin
    Fan, Yan
    Zhang, Wenyuan
    Yang, Xiaogang
    Liu, Jiacheng
    MICROCHIMICA ACTA, 2025, 192 (02)
  • [22] A water-soluble colorimetric and ratiometric fluorescent probe based on phenothiazine for the detection of hypochlorite ion
    Liu, Qianling
    Xiao, Ming
    Ding, Haichang
    Fan, Congbin
    Liu, Gang
    Pu, Shouzhi
    DYES AND PIGMENTS, 2023, 215
  • [23] Realizing the Ultrafast Recovery of the Monolayer MoS2-Based NH3 Sensor by Gas-Ion-Gate
    Zhao, Lei
    Wang, Xinqin
    Zhang, Zhengrong
    Ji, Yongqiang
    Guo, Junmeng
    Du, Zuliang
    Cheng, Gang
    ACS APPLIED MATERIALS & INTERFACES, 2025, 17 (11) : 17465 - 17475
  • [24] Colorimetric sensor for Pb2+ detection in water using thioglycolic acid-conjugated gold nanoparticles
    Saputri, Febrina Amelia
    Aulia, Talitha Shabirah
    Jatmika, Catur
    Iswandana, Raditya
    Megantara, Sandra
    Dhumale, Vinayak A.
    RSC ADVANCES, 2025, 15 (09) : 6931 - 6937
  • [25] Saccharide detection based on the amplified fluorescence quenching of a water-soluble poly(phenylene ethynylene) by a boronic acid functionalized benzyl viologen derivative
    DiCesare, N
    Pinto, MR
    Schanze, KS
    Lakowicz, JR
    LANGMUIR, 2002, 18 (21) : 7785 - 7787
  • [26] Rapid and selective detection of aluminum ion using 1,2,3-triazole-4,5-dicarboxylic acid-functionalized gold nanoparticle-based colorimetric sensor
    Zhao, Shengliang
    Chen, Liqiong
    Liu, Feiyan
    Fan, Yongyao
    Liu, Yiheng
    Han, Yulai
    Hu, Yunfei
    Su, Jingyun
    Song, Chunyan
    RSC ADVANCES, 2021, 11 (49) : 30635 - 30645
  • [27] Detection of sparfloxacin based on water-soluble CuInS2 quantum dots
    Fang, Jiajia
    Dong, Beina
    Fu, Yingqiang
    Tang, Dingxing
    RESULTS IN CHEMISTRY, 2020, 2
  • [28] USE OF AMBERLITE XAD-2 FOR ISOLATION AND DETECTION OF WATER-SOLUBLE ACID DYES
    UEMATSU, T
    KURITA, T
    HAMADA, A
    JOURNAL OF CHROMATOGRAPHY, 1979, 172 (APR): : 327 - 334
  • [29] MoS2-Based Optoelectronic Gas Sensor with Sub-parts-per-billion Limit of NO2 Gas Detection
    Tung Pham
    Li, Guanghui
    Bekyarova, Elena
    Itkis, Mikhail E.
    Mulchandani, Ashok
    ACS NANO, 2019, 13 (03) : 3196 - 3205
  • [30] Lignin based water-soluble fluorescent macromolecular probes for the detection of Fe3+ion
    Wu, Yufan
    Zhang, Siyuan
    Cheng, Xinjian
    INDUSTRIAL CROPS AND PRODUCTS, 2024, 208