Methodology for optimally sized centrifugal partition chromatography columns

被引:36
作者
Chollet, Sebastien [1 ,2 ]
Marchal, Luc [1 ]
Meucci, Jeremy [2 ]
Renault, Jean-Hugues [3 ]
Legrand, Jack [1 ]
Foucault, Alain [1 ]
机构
[1] Univ Nantes, GEPEA, UMR CNRS 6144, F-44602 St Nazaire, France
[2] Rousselet Centrifugat SA, Kromaton, Annonay, France
[3] Univ Reims, ICMR, UMR CNRS 7312, F-51100 Reims, France
关键词
Centrifugal Partition Chromatography; Mass transfer; Flow pattern; Engineering; Scale-up method; COUNTER-CURRENT CHROMATOGRAPHY; FLOW REGIMES; ION-EXCHANGE; SEPARATION; SYSTEMS; PURIFICATION; IMPROVEMENT; EXTRACTION; BINARY;
D O I
10.1016/j.chroma.2015.02.043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Centrifugal Partition Chromatography (CPC) is a separation process based on the partitioning of solutes between two partially miscible liquid phases. There is no solid support for the stationary phase. The centrifugal acceleration is responsible for both stationary phase retention and mobile phase dispersion. CPC is thus a process based on liquid-liquid mass transfer. The separation efficiency is mainly influenced by the hydrodynamics of the phases in each cell of the column. Thanks to a visualization system, called "Visual CPC", it was observed that the mobile phase can flow through the stationary phase as a sheet, or a spray. Hydrodynamics, which directly governs the instrument efficiency, is directly affected during scale changes, and non-linear phenomena prevent the successful achievement of mastered geometrical scale changes. In this work, a methodology for CPC column sizing is proposed, based on the characterization of the efficiency of advanced cell shapes, taking into account the hydrodynamics. Knowledge about relationship between stationary phase volume, cell efficiency and separation resolution in CPC allowed calculating the optimum cell number for laboratory and industrial scale CPC application. The methodology is highlighted with results on five different geometries from 25 to 5000 mL, for two applications: the separation of alkylbenzene by partitioning with heptane/methanol/water biphasic system; and the separation of peptides by partitioning with n-butanol/acetic acid/water (4/1/5) biphasic system. With this approach, it is possible to predict the optimal CPC column length leading to highest productivity. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:174 / 183
页数:10
相关论文
共 29 条
[1]   INTERFACIAL-TENSIONS IN BINARY AND TERNARY LIQUID LIQUID-SYSTEMS [J].
BACKES, HM ;
JING, JM ;
BENDER, E ;
MAURER, G .
CHEMICAL ENGINEERING SCIENCE, 1990, 45 (01) :275-286
[2]  
Berthod A., 1991, ANAL CHEM, V63, P5
[3]   On physically similar systems, illustrations of the use of dimensional equations [J].
Buckingham, E .
PHYSICAL REVIEW, 1914, 4 (04) :345-376
[4]  
Carberry J. J., 2001, CHEM CATALYTIC REACT, P642
[5]   Improvement purification of sulfated oligofucan by ion-exchange displacement centrifugal partition chromatography [J].
Chevolot, L ;
Foucault, A ;
Colliec-Jouault, S ;
Ratiskol, J ;
Sinquin, C .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :353-361
[6]  
De la Poype F., 1999, Patent, Patent No. [WO0058722 (A1), 0058722]
[7]  
Foucault A. P., 2009, Pattent, Patent No. [WO20092914 (A1), 20092914]
[8]  
Foucault A. P., 2005, Patent, Patent No. [WO2005093406 (A1), 2005093406]
[9]  
Foucault A.P., 1995, CENTRIFUGAL PARTITIO
[10]   Enantioseparations in counter-current chromatography and centrifugal partition chromatography [J].
Foucault, AP .
JOURNAL OF CHROMATOGRAPHY A, 2001, 906 (1-2) :365-378