Design, Optimization and Energetic Evaluation of an Efficient Fully Powered Ankle-Foot Prosthesis With a Series Elastic Actuator

被引:16
|
作者
Dong, Dianbiao [1 ,2 ]
Ge, Wenjie [1 ]
Convens, Bryan [2 ]
Sun, Yuanxi [3 ]
Verstraten, Tom [2 ]
Vanderborght, Bram [2 ]
机构
[1] Northwestern Polytech Univ, Sch Mech Engn, Xian 710072, Peoples R China
[2] Vrije Univ Brussel, Dept Mech Engn, B-1050 Brussels, Belgium
[3] Chongqing Univ, Coll Mech Engn, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
Actuator; efficiency; peak power; prosthesis; series elastic actuator; GEARED DC MOTORS; WALKING; GAIT;
D O I
10.1109/ACCESS.2020.2983518
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The use of powered ankle-foot prostheses for below-knee amputees leads to challenges like the peak power of the applied actuator and biomechanical features of the prosthesis foot. This paper proposes an efficient powered ankle-foot prosthesis with a series elastic actuator. By combining the geared five-bar spring (GFBS) mechanism and the traditional series elastic actuator (SEA), a series elastic with geared five-bar (SGFB) actuator is built. The new SGFB actuator has the benefits of both the GFBS and the SEA on mimicking biomechanics of the human ankle and reducing the peak power of the motor. The healthy walking gait in the experiment results indicates that the optimized SGFB prosthesis foot including a 150W Maxon DC motor can provide a 70kg subject enough net positive energy with an energy efficiency of 35.3% during normal speed walking in the treadmill trials. The experiment of the SGFB prosthesis foot in semi-active mode shows the advantage on closely mimicking the human biomechanics during the control dorsiflexion phase and the importance of injecting positive energy during the powered plantarflexion phase. The experiment results also show that the optimization of different parameters within the electromechanical model considering the efficiency of the whole drive train can effectively reduce the motor's peak power to 132 W by making the motor more effective in high-power conditions.
引用
收藏
页码:61491 / 61503
页数:13
相关论文
共 50 条
  • [41] Robust Optimal Design of Energy Efficient Series Elastic Actuators: Application to a Powered Prosthetic Ankle
    Bolivar, Edgar
    Rezazadeh, Siavash
    Summers, Tyler
    Gregg, Robert D.
    2019 IEEE 16TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2019, : 740 - 747
  • [42] Effects of a Powered Ankle-Foot Prosthesis and Physical Therapy on Function for Individuals With Transfemoral Limb Loss: Rationale, Design, and Protocol for a Multisite Clinical Trial
    Maikos, Jason
    Pruziner, Alison L.
    Hendershot, Brad
    Herlihy, David, V
    Chomack, M.
    Hyre, Michael J.
    Phillips, Samuel L.
    Sidiropoulos, Alexis N.
    Dearth, Christopher L.
    Nelson, Leif M.
    JMIR RESEARCH PROTOCOLS, 2024, 13
  • [43] Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study
    Rogati, Giulia
    Caravaggi, Paolo
    Leardini, Alberto
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2022, 15 (01)
  • [44] Design, implementation, and evaluation of a backstepping control algorithm for an active ankle-foot orthosis
    Kirtas, Oguzhan
    Savas, Yagiz
    Bayraker, Melih
    Baskaya, Faik
    Basturk, Halil
    Samur, Evren
    CONTROL ENGINEERING PRACTICE, 2021, 106
  • [45] Systematic Assessment of Prosthesis Stiffness on User Biomechanics Using the Lower Leg Trajectory Error Framework and Its Implication for the Design and Evaluation of Ankle-Foot Prostheses
    Prost, Victor
    Johnson, W. Brett
    Kent, Jenny A. A.
    Major, Matthew J. J.
    Winter, Amos G. G.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2023, 145 (04):
  • [46] Toward Developing a Powered Ankle-Foot Prosthesis With Electromyographic Control to Enhance Functional Performance: A Case Study in a US Service Member
    Knight, Ashley D.
    Bass, Sarah R.
    Elrod, Jonathan M.
    Hassinger, Louise M.
    Dearth, Christopher L.
    Gonzalez-Vargas, Jose
    Hendershot, Brad D.
    Han, Zhixiu
    MILITARY MEDICINE, 2023, 188 (7-8) : E2772 - E2777
  • [47] Investigations of roll-over shape: implications for design, alignment, and evaluation of ankle-foot prostheses and orthoses
    Hansen, Andrew H.
    Childress, Dudley S.
    DISABILITY AND REHABILITATION, 2010, 32 (26) : 2201 - 2209
  • [48] Does Use of a Powered Ankle-foot Prosthesis Restore Whole-body Angular Momentum During Walking at Different Speeds?
    D'Andrea, Susan
    Wilhelm, Natalie
    Silverman, Anne K.
    Grabowski, Alena M.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (10) : 3044 - 3054
  • [49] Modeling, Design and Test-Bench Validation of a Semi-Active Propulsive Ankle Prosthesis With a Clutched Series Elastic Actuator
    Convens, Bryan
    Dong, Dianbiao
    Furnemont, Raphael
    Verstraten, Tom
    Cherelle, Pierre
    Lefeber, Dirk
    Vanderborght, Bram
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2019, 4 (02) : 1823 - 1830
  • [50] Design and Reflex Control for a Series Elastic Actuator based Ankle Joint Emulator
    Li, Mingwen
    Pang, Muye
    Xiang, Kui
    Ju, Zhaojie
    Zhou, Shenpei
    2018 3RD IEEE INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (IEEE ICARM), 2018, : 818 - 823