Design, Optimization and Energetic Evaluation of an Efficient Fully Powered Ankle-Foot Prosthesis With a Series Elastic Actuator

被引:16
|
作者
Dong, Dianbiao [1 ,2 ]
Ge, Wenjie [1 ]
Convens, Bryan [2 ]
Sun, Yuanxi [3 ]
Verstraten, Tom [2 ]
Vanderborght, Bram [2 ]
机构
[1] Northwestern Polytech Univ, Sch Mech Engn, Xian 710072, Peoples R China
[2] Vrije Univ Brussel, Dept Mech Engn, B-1050 Brussels, Belgium
[3] Chongqing Univ, Coll Mech Engn, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
Actuator; efficiency; peak power; prosthesis; series elastic actuator; GEARED DC MOTORS; WALKING; GAIT;
D O I
10.1109/ACCESS.2020.2983518
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The use of powered ankle-foot prostheses for below-knee amputees leads to challenges like the peak power of the applied actuator and biomechanical features of the prosthesis foot. This paper proposes an efficient powered ankle-foot prosthesis with a series elastic actuator. By combining the geared five-bar spring (GFBS) mechanism and the traditional series elastic actuator (SEA), a series elastic with geared five-bar (SGFB) actuator is built. The new SGFB actuator has the benefits of both the GFBS and the SEA on mimicking biomechanics of the human ankle and reducing the peak power of the motor. The healthy walking gait in the experiment results indicates that the optimized SGFB prosthesis foot including a 150W Maxon DC motor can provide a 70kg subject enough net positive energy with an energy efficiency of 35.3% during normal speed walking in the treadmill trials. The experiment of the SGFB prosthesis foot in semi-active mode shows the advantage on closely mimicking the human biomechanics during the control dorsiflexion phase and the importance of injecting positive energy during the powered plantarflexion phase. The experiment results also show that the optimization of different parameters within the electromechanical model considering the efficiency of the whole drive train can effectively reduce the motor's peak power to 132 W by making the motor more effective in high-power conditions.
引用
收藏
页码:61491 / 61503
页数:13
相关论文
共 50 条
  • [31] Personalized design of ankle-foot prosthesis based on computer modeling of amputee locomotion
    Gharini, Mohammad
    Mohammadi Moghaddam, Majid
    Farahmand, Farzam
    ASSISTIVE TECHNOLOGY, 2020, 32 (02) : 100 - 108
  • [32] THE APPLICATION OF SERIES ELASTIC ACTUATORS IN THE HYDRAULIC ANKLE-FOOT ORTHOSIS
    Kim, Jeong Yong
    Durfee, William
    2018 DESIGN OF MEDICAL DEVICES CONFERENCE, 2018,
  • [33] Design and development of a novel viscoelastic ankle-foot prosthesis based on the human ankle biomechanics
    Safaeepour, Zahra
    Esteki, Ali
    Ghomshe, Farhad Tabatabai
    Mousavai, Mohammad E.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2014, 38 (05) : 400 - 404
  • [34] Ankle Kinematics Describing Gait Agility: Considerations in the Design of an Agile Ankle-Foot Prosthesis
    Ficanha, Evandro M.
    Kang, Ruiyu
    Rastgaar, Mohammad
    2014 5TH IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2014, : 132 - 137
  • [35] Biomedical Design of Powered Ankle- Foot Prosthesis - A Review
    Debta, Sanghamitra
    Kumar, Kaushik
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (02) : 3273 - 3282
  • [36] A PNEUMATIC VARIABLE SERIES ELASTIC ACTUATOR-POWERED TRANSTIBIAL PROSTHESIS
    Zheng, Hao
    Wu, Molei
    Shen, Xiangrong
    INTERNATIONAL JOURNAL OF ROBOTICS & AUTOMATION, 2020, 35 (06) : 408 - 418
  • [37] Preliminary Design and Engineering Evaluation of a Hydraulic Ankle-Foot Orthosis
    Neubauer, Brett
    Durfee, William
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (04): : 1 - 9
  • [38] Parametric Design of an Advanced Multi-Axial Energy-Storing-and-Releasing Ankle-Foot Prosthesis
    Leopaldi, Marco
    Brugo, Tommaso Maria
    Tabucol, Johnnidel
    Zucchelli, Andrea
    PROSTHESIS, 2024, 6 (04): : 726 - 743
  • [39] Energetic analysis and optimization of a MACCEPA actuator in an ankle prosthesisEnergetic evaluation of the CYBERLEGs alpha-prosthesis variable stiffness actuator during a realistic load cycle
    Joost Geeroms
    Louis Flynn
    Rene Jimenez-Fabian
    Bram Vanderborght
    Dirk Lefeber
    Autonomous Robots, 2018, 42 : 147 - 158
  • [40] Design and Validation of a Two-Degree-of-Freedom Powered Ankle-Foot Orthosis with Two Pneumatic Artificial Muscles
    Choi, Ho Seon
    Lee, Chang Hee
    Baek, Yoon Su
    MECHATRONICS, 2020, 72 (72)