Resonance Scattering Spectral Detection of Trace Pb2+ Using Aptamer-Modified AuPd Nanoalloy as Probe

被引:32
作者
Jiang, Zhiliang [1 ]
Fan, Yanyan [1 ]
Liang, Aihui [1 ]
Wen, Guiqing [1 ]
Liu, Qingye [1 ]
Li, Tingsheng [1 ]
机构
[1] Guangxi Normal Univ, Guangxi Key Lab Environm Engn Protect & Assessmen, Guilin 541004, Peoples R China
基金
中国国家自然科学基金;
关键词
Pb2+; Aptamer probe; Au/Pd nanoalloy; Nanocatalysis; Resonance scattering spectral assay; RAYLEIGH-SCATTERING; GOLD NANOPARTICLES; LIGHT-SCATTERING; LEAD IONS; ELECTROCHEMICAL DETECTION; CATALYTIC-REACTION; DNA HYBRIDIZATION; ASSAY; NANOGOLD; DNAZYME;
D O I
10.1007/s11468-010-9153-8
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The resonance scattering spectral probe for Pb2+ was obtained using aptamer-modified AuPd Nanoalloy. In the pH 7.0 Na2HPO4-NaH2PO4 buffer solution, the aptamer interacted with AuPd nanoalloy particles to form stable aptamer-AuPd nanoalloy probe for Pb2+ that is stable in high concentration of salt. The probe combined with Pb2+ ions to form a G-quadruplex and to release AuPd nanoalloy particles that aggregate to form big particles which led the resonance scattering (RS) intensity enhancing. The reaction solution was filtered by 0.15 mu m membrane to obtain the filtration containing aptamer-AuPd nanoalloy probe that has strong catalytic effect on the electrodeless nickel particle plating reaction between Ni(II) and PO23- that exhibited a strong RS peak at 508 nm. The RS intensity at 508 nm decreased when the Pb2+ concentration increased. The decreased intensity (Delta I-508nm) is linear to the concentration of 0.08-42 nM Pb2+, with regress equation of Delta I-508nm = 16.3c + 1.5, correlation coefficient of 0.9965, and detection limit of 0.04 nM Pb2+. The RS assay was applied to the analysis of Pb2+ in wastewater, with satisfactory results.
引用
收藏
页码:375 / 381
页数:7
相关论文
共 33 条
[1]   Molecular aptamers for real-time protein-protein interaction study [J].
Cao, ZH ;
Tan, WH .
CHEMISTRY-A EUROPEAN JOURNAL, 2005, 11 (15) :4502-4508
[2]   Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads [J].
Centi, Sonia ;
Tombelli, Sara ;
Minunni, Maria ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1466-1473
[3]   Electrochemical detection of lead ions via the covalent attachment of human angiotensin I to mercaptopropionic acid and thioctic acid self-assembled monolayers [J].
Chow, E ;
Hibbert, DB ;
Gooding, JJ .
ANALYTICA CHIMICA ACTA, 2005, 543 (1-2) :167-176
[4]   One-step homogeneous detection of DNA hybridization with gold nanoparticle probes by using a linear light-scattering technique [J].
Du, Bao-An ;
Li, Zheng-Ping ;
Liu, Cheng-Hui .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (47) :8022-8025
[5]   Aptamers as ligands in affinity probe capillary electrophoresis [J].
German, I ;
Buchanan, DD ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 1998, 70 (21) :4540-4545
[6]   Determination of chromium(VI) by surface plasmon field-enhanced resonance light scattering [J].
Han, Zhiqiang ;
Qi, Li ;
Shen, Gangyi ;
Liu, Wei ;
Chen, Yi .
ANALYTICAL CHEMISTRY, 2007, 79 (15) :5862-5868
[7]   Novel approach to analyzing RNA aptamer-protein interactions: Toward further applications of aptamers [J].
Hwang, Joonsung ;
Nishikawa, Satoshi .
JOURNAL OF BIOMOLECULAR SCREENING, 2006, 11 (06) :599-605
[8]  
Jiang ZL, 2008, CHEM J CHINESE U, V29, P1973
[9]   Nanogold catalysis-based immunoresonance-scattering spectral assay for trace complement component 3 [J].
Jiang, Zhiliang ;
Huang, Wenxing ;
Li, Jiangping ;
Li, Mingshun ;
Liang, Aihui ;
Zhang, Shengsen ;
Chen, Bing .
CLINICAL CHEMISTRY, 2008, 54 (01) :116-123
[10]   Resonance Scattering Spectral Detection of Trace Hg2+ Using Aptamer-Modified Nanogold as Probe and Nanocatalyst [J].
Jiang, Zhiliang ;
Fan, Yanyan ;
Chen, Menglin ;
Liang, Aihui ;
Liao, Xianjiu ;
Wen, Guiqing ;
Shen, Xingcan ;
He, Xingcun ;
Pan, Hongchen ;
Jiang, Hesheng .
ANALYTICAL CHEMISTRY, 2009, 81 (13) :5439-5445