An evaluation of bag-valve-mask ventilation using an ergonomically designed facemask among novice users: A simulation-based pilot study

被引:13
作者
Bauman, Eric B. [1 ]
Joffe, Aaron M. [2 ]
Lenz, Lynn [3 ]
DeVries, Stephen A. [4 ]
Hetzel, Scott [5 ]
Seider, Samuel P. [6 ]
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Dept Anesthesiol, Madison, WI 53706 USA
[2] Univ Washington, Harborview Med Ctr, Dept Anesthesiol & Pain Med, Seattle, WA 98104 USA
[3] Western Tech Coll, La Crosse, WI USA
[4] Tri State Ambulance, La Crosse, WI USA
[5] Univ Wisconsin Madison, Dept Biostat & Med Informat, Madison, WI USA
[6] Univ Wisconsin Madison, Coll Letters & Sci, Madison, WI USA
关键词
Resuscitation; Airway management; Facemask; Ventilation; DIFFICULT;
D O I
10.1016/j.resuscitation.2010.05.005
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: We sought to compare the ability of novice operators to provide artificial ventilation using a standard facemask and a new ergonomically designed facemask. Whether or not proper technique was used was also assessed. Methods: Thirty-two allied-health students used both masks in random crossover fashion to ventilate an airway trainer. Breaths were delivered by a mechanical ventilator and exhaled tidal volume was recorded for each of 12 breaths for each participant for each mask. The effect of each mask during ventilation over time was assessed using repeated-measures ANOVA. Assessment of mask technique among participants and association between mask type and hand repositioning were analyzed using the Wilcoxon-Rank Sum Test and McNemar's paired proportions test, respectively. Results: The tidal volume achieved when participants used the ergonomic mask was higher than when participants used the standard mask by the fourth breath (361 +/- 104 mL vs. 264 +/- 163 mL; Bonferroni adjusted p-value = 0.040) and increased over time. The repeated-measures ANOVA showed that the ergonomic mask consistently resulted in higher tidal volumes than the standard mask regardless of rescuer's gender. Over time the standard mask resulted in a linear decrease in tidal volume of -10 mL/breath (estimated difference in decay of 10 mL/breath versus the ergonomic mask; p < 0.001). Conclusion: Novice airway operators were better able to provide facemask ventilation using an ergonomically designed mask than with a traditional facemask. We conclude that better hand position facilitating improved mask seal and less operator fatigue account for our findings. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1161 / 1165
页数:5
相关论文
共 14 条
[1]  
*AM HEART ASS, 2006, BLS HEALTHC PROV
[3]   AN EVALUATION OF EMERGENCY MEDICAL TECHNICIANS ABILITY TO USE MANUAL VENTILATION DEVICES [J].
ELLING, R ;
POLITIS, J .
ANNALS OF EMERGENCY MEDICINE, 1983, 12 (12) :765-768
[4]  
Field J.M., 2006, ADV CARDIOVASCULAR L
[5]  
Gabrielli Andrea, 2002, Curr Opin Crit Care, V8, P199, DOI 10.1097/00075198-200206000-00002
[6]   Incidence and predictors of difficult and impossible mask ventilation [J].
Kheterpal, Sachin ;
Han, Richard ;
Tremper, Kevin K. ;
Shanks, Amy ;
Tait, Alan R. ;
O'Reilly, Michael ;
Ludwig, Thomas A. .
ANESTHESIOLOGY, 2006, 105 (05) :885-891
[7]   Gender difference in mask ventilation training of anesthesia residents [J].
Koga, Tomomichi ;
Kawamoto, Masashi .
JOURNAL OF CLINICAL ANESTHESIA, 2009, 21 (03) :178-182
[8]   Airway management in cardiac arrest - comparison of the laryngeal tube, tracheal intubation and bag-valve mask ventilation in emergency medical training [J].
Kurola, J ;
Harve, H ;
Kettunen, T ;
Laakso, JP ;
Gorski, J ;
Paakkonen, H ;
Silfvast, T .
RESUSCITATION, 2004, 61 (02) :149-153
[9]   Prediction of difficult mask ventilation [J].
Langeron, O ;
Masso, E ;
Huraux, C ;
Guggiari, M ;
Bianchi, A ;
Coriat, P ;
Riou, B .
ANESTHESIOLOGY, 2000, 92 (05) :1229-1236
[10]   The adult ergonomic face mask concept: historical and theoretical perspectives [J].
Matioc, Adrian A. .
JOURNAL OF CLINICAL ANESTHESIA, 2009, 21 (04) :300-304