Continuous flow biphasic positive airway pressure by helmet in patients with acute hypoxic respiratory failure: effect on oxygenation

被引:8
|
作者
Isgro, Stefano [1 ]
Zanella, Alberto [1 ]
Sala, Chiara [1 ]
Grasselli, Giacomo [2 ]
Foti, Giuseppe [2 ]
Pesenti, Antonio [1 ,2 ]
Patroniti, Nicolo [1 ,2 ]
机构
[1] Univ Milano Bicocca, Dept Expt Med, Azienda Osped San Gerardo, I-20048 Monza, MI, Italy
[2] San Gerardo Hosp, Dept Perioperat Med & Intens Care, I-20052 Monza, MI, Italy
关键词
Helmet; Noninvasive continuous positive airway pressure; Biphasic positive pressure ventilation (BIPAP); Airway pressure release ventilation (APRV); DELIVER NONINVASIVE VENTILATION; OBSTRUCTIVE PULMONARY-DISEASE; DISTRESS-SYNDROME; RELEASE VENTILATION; MECHANICAL VENTILATION; SUPPORT VENTILATION; CONTROLLED-TRIAL; GAS-EXCHANGE; FACE MASK; SIGH;
D O I
10.1007/s00134-010-1925-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We investigated the effects of periodical high pressure breaths (SIGH) or biphasic positive pressure ventilation (BIPAP) during helmet continuous positive airway pressure (CPAP) in patients with acute hypoxic respiratory failure. We used a recently developed electromechanical expiratory valve (TwinPAP(A (R)), StarMed, Mirandola, Italy), which is time-cycled between two customizable positive end-expiratory pressure (PEEP) levels. We studied 21 patients (67 +/- A 17 years old) undergoing helmet CPAP. Continuous flow CPAP system was set at 60 l/min flow rate while maintaining clinical FiO(2) (51 +/- A 15%). Five steps, lasting 1 h each, were applied: (1) spontaneous breathing with PEEP 0 cmH(2)O (SB), (2) CPAP with PEEP 8 cmH(2)O (CPAP(basal)), (3) low PEEP, 8 cmH(2)O, for 25 s and high PEEP, 25 cmH(2)O, for 5 s (SIGH), (4) low PEEP, 8 cmH(2)O, for 3 s and high PEEP, 20 cmH(2)O, for 3 s (BIPAP), (5) CPAP with PEEP 8 cmH(2)O (CPAP(final)). We randomized the sequence of SIGH and BIPAP. PaO2 was significantly higher during all steps compared to SB. When compared to CPAP(basal), both SIGH and BIPAP induced a further increase in PaO2. PaO2 during SIGH and BIPAP were not different. The oxygenation improvement was maintained during CPAP(final). Superimposed, nonsynchronized positive pressure breaths delivered during helmet CPAP by means of the TwinPAP(A (R)) system may improve oxygenation in patients with acute hypoxemic respiratory failure, even at a rate as low as two breaths per minute.
引用
收藏
页码:1688 / 1694
页数:7
相关论文
共 50 条
  • [21] Prehospital treatment with continuous positive airway pressure in patients with acute respiratory failure: a regional observational study
    Nielsen, Vibe Maria Laden
    Madsen, Jacob
    Aasen, Anette
    Toft-Petersen, Anne Pernille
    Lubcke, Kenneth
    Rasmussen, Bodil Steen
    Christensen, Erika Frischknecht
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2016, 24
  • [22] POSITIVE AIRWAY PRESSURE IN ACUTE RESPIRATORY-FAILURE
    不详
    MEDICAL JOURNAL OF AUSTRALIA, 1974, 1 (04) : 85 - 85
  • [23] Biphasic Positive Airway Pressure or Continuous Positive Airway Pressure: A Randomized Trial
    Victor, Suresh
    Roberts, Stephen A.
    Mitchell, Simon
    Aziz, Huma
    Lavender, Tina
    PEDIATRICS, 2016, 138 (02)
  • [24] Critical care patients' experience of the helmet continuous positive airway pressure
    Dimech, Andrew
    NURSING IN CRITICAL CARE, 2012, 17 (01) : 36 - 43
  • [25] Helmet noninvasive ventilation in acute hypoxic respiratory failure
    Buell, Kevin G.
    Patel, Bhakti K.
    CURRENT OPINION IN CRITICAL CARE, 2023, 29 (01) : 8 - 13
  • [26] High-Flow Nasal Oxygen versus Continuous Positive Airway Pressure in patients with hypoxemic acute respiratory failure due to pneumonia
    Antonucci, Elio
    Giovini, Manuela
    Cecchia, Martina
    Bergonzi, Manuela
    Gandol, Stefano
    Orlando, Sergio
    Barbera, Mario
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2023, 50
  • [27] Treatment of respiratory failure with noninvasive continuous positive airway pressure
    Bendjelid, K
    Suter, PM
    Romand, J
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (07): : 880 - 880
  • [28] THE APPLICATION OF CONTINUOUS POSITIVE AIRWAY PRESSURE IN THE PRESENCE AND ABSENCE OF PERIODIC HYPERINFLATIONS VIA HELMET TO TREAT MILD TO MODERATE ACUTE HYPOXEMIC RESPIRATORY FAILURE
    Turucz, E.
    Vaschetto, R.
    Cammarota, G.
    Dellapiazza, F.
    Blando, C.
    Colombo, D.
    Della Corte, F.
    Navalesi, P.
    INTENSIVE CARE MEDICINE, 2009, 35 : 20 - 20
  • [29] NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE IN PATIENTS WITH COPD IN ACUTE RESPIRATORY-FAILURE - A STUDY OF THE IMMEDIATE EFFECTS
    DELUCAS, P
    TARANCON, C
    PUENTE, L
    RODRIGUEZ, C
    TATAY, E
    MONTURIOL, JM
    CHEST, 1993, 104 (06) : 1694 - 1697
  • [30] Hemodynamic effects of continuous positive airway pressure in patients with acute heart failure
    Battistoni, I. Ilaria
    Marini, M. M.
    Angelini, L. A.
    Shkoza, M. S.
    Francioni, M. F.
    Gili, A. G.
    Moretti, S. M.
    Perna, G. P. P.
    EUROPEAN JOURNAL OF HEART FAILURE, 2016, 18 : 180 - 180