Continuous flow biphasic positive airway pressure by helmet in patients with acute hypoxic respiratory failure: effect on oxygenation

被引:8
作者
Isgro, Stefano [1 ]
Zanella, Alberto [1 ]
Sala, Chiara [1 ]
Grasselli, Giacomo [2 ]
Foti, Giuseppe [2 ]
Pesenti, Antonio [1 ,2 ]
Patroniti, Nicolo [1 ,2 ]
机构
[1] Univ Milano Bicocca, Dept Expt Med, Azienda Osped San Gerardo, I-20048 Monza, MI, Italy
[2] San Gerardo Hosp, Dept Perioperat Med & Intens Care, I-20052 Monza, MI, Italy
关键词
Helmet; Noninvasive continuous positive airway pressure; Biphasic positive pressure ventilation (BIPAP); Airway pressure release ventilation (APRV); DELIVER NONINVASIVE VENTILATION; OBSTRUCTIVE PULMONARY-DISEASE; DISTRESS-SYNDROME; RELEASE VENTILATION; MECHANICAL VENTILATION; SUPPORT VENTILATION; CONTROLLED-TRIAL; GAS-EXCHANGE; FACE MASK; SIGH;
D O I
10.1007/s00134-010-1925-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We investigated the effects of periodical high pressure breaths (SIGH) or biphasic positive pressure ventilation (BIPAP) during helmet continuous positive airway pressure (CPAP) in patients with acute hypoxic respiratory failure. We used a recently developed electromechanical expiratory valve (TwinPAP(A (R)), StarMed, Mirandola, Italy), which is time-cycled between two customizable positive end-expiratory pressure (PEEP) levels. We studied 21 patients (67 +/- A 17 years old) undergoing helmet CPAP. Continuous flow CPAP system was set at 60 l/min flow rate while maintaining clinical FiO(2) (51 +/- A 15%). Five steps, lasting 1 h each, were applied: (1) spontaneous breathing with PEEP 0 cmH(2)O (SB), (2) CPAP with PEEP 8 cmH(2)O (CPAP(basal)), (3) low PEEP, 8 cmH(2)O, for 25 s and high PEEP, 25 cmH(2)O, for 5 s (SIGH), (4) low PEEP, 8 cmH(2)O, for 3 s and high PEEP, 20 cmH(2)O, for 3 s (BIPAP), (5) CPAP with PEEP 8 cmH(2)O (CPAP(final)). We randomized the sequence of SIGH and BIPAP. PaO2 was significantly higher during all steps compared to SB. When compared to CPAP(basal), both SIGH and BIPAP induced a further increase in PaO2. PaO2 during SIGH and BIPAP were not different. The oxygenation improvement was maintained during CPAP(final). Superimposed, nonsynchronized positive pressure breaths delivered during helmet CPAP by means of the TwinPAP(A (R)) system may improve oxygenation in patients with acute hypoxemic respiratory failure, even at a rate as low as two breaths per minute.
引用
收藏
页码:1688 / 1694
页数:7
相关论文
共 50 条
  • [1] Continuous flow biphasic positive airway pressure by helmet in patients with acute hypoxic respiratory failure: effect on oxygenation
    Stefano Isgrò
    Alberto Zanella
    Chiara Sala
    Giacomo Grasselli
    Giuseppe Foti
    Antonio Pesenti
    Nicolò Patroniti
    Intensive Care Medicine, 2010, 36 : 1688 - 1694
  • [2] Noninvasive Continuous Positive Airway Pressure in Acute Respiratory Failure: Helmet Versus Facial Mask
    Chidini, Giovanna
    Calderini, Edoardo
    Cesana, Bruno Mario
    Gandini, Cristiano
    Prandi, Edi
    Pelosi, Paolo
    PEDIATRICS, 2010, 126 (02) : E330 - E336
  • [3] Noninvasive continuous positive airway pressure delivered by helmet in hematological malignancy patients with hypoxemic acute respiratory failure
    Tiziana Principi
    Simona Pantanetti
    Francesca Catani
    Daniele Elisei
    Vincenzo Gabbanelli
    Paolo Pelaia
    Pietro Leoni
    Intensive Care Medicine, 2004, 30 : 147 - 150
  • [4] Noninvasive continuous positive airway pressure delivered by helmet in hematological malignancy patients with hypoxemic acute respiratory failure
    Principi, T
    Pantanetti, S
    Catani, F
    Elisei, D
    Gabbanelli, V
    Pelaia, P
    Leoni, P
    INTENSIVE CARE MEDICINE, 2004, 30 (01) : 147 - 150
  • [5] Randomized clinical trial comparing helmet continuous positive airway pressure (hCPAP) to facemask continuous positive airway pressure (fCPAP) for the treatment of acute respiratory failure in the emergency department
    Adi, Osman
    Via, Gabriele
    Salleh, Siti Hafsah
    Chuan, Tan Wan
    Ab Rahman, Jamalludin
    Muhammad, Nik Azlan Nik
    Atan, Rafidah
    Anaes, M.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 49 : 385 - 392
  • [6] Continuous positive airway pressure (CPAP) provision with a pediatric helmet for treatment of hypoxemic acute respiratory failure in dogs
    Ceccherini, Gianila
    Lippi, Ilaria
    Citi, Simonetta
    Perondi, Francesca
    Pamapanini, Michela
    Guidi, Grazia
    Briganti, Angela
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2020, 30 (01) : 41 - 49
  • [7] Treatment of acute hypoxemic respiratory failure with continuous positive airway pressure delivered by a new pediatric helmet in comparison with a standard full face mask: A prospective pilot study
    Chidini, Giovanna
    Calderini, Edoardo
    Pelosi, Paolo
    PEDIATRIC CRITICAL CARE MEDICINE, 2010, 11 (04) : 502 - 508
  • [8] Elevated Extravascular Lung Water Index (ELWI) as a Predictor of Failure of Continuous Positive Airway Pressure Via Helmet (Helmet-CPAP) in Patients With Acute Respiratory Failure After Major Surgery
    Redondo Calvo, Francisco Javier
    Bejarano Ramirez, Natalia
    Una Orejon, Rafael
    Villazala Garcia, Ruben
    Yuste Pena, Ana Sofia
    Javier Belda, Francisco
    ARCHIVOS DE BRONCONEUMOLOGIA, 2015, 51 (11): : 558 - 563
  • [9] PREHOSPITAL CONTINUOUS POSITIVE AIRWAY PRESSURE FOR ACUTE RESPIRATORY FAILURE: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Williams, Teresa A.
    Finn, Judith
    Perkins, Gavin D.
    Jacobs, Ian G.
    PREHOSPITAL EMERGENCY CARE, 2013, 17 (02) : 261 - 273
  • [10] PREHOSPITAL USE OF CONTINUOUS POSITIVE AIRWAY PRESSURE FOR ACUTE SEVERE CONGESTIVE HEART FAILURE
    Dib, Joe E.
    Matin, Scott A.
    Luckert, Amy
    JOURNAL OF EMERGENCY MEDICINE, 2012, 42 (05) : 553 - 558