Corrosion Behavior of Titanium Implant with different Surface Morphologies

被引:22
|
作者
Wang, Guisen [1 ]
Wan, Yi [1 ]
Wang, Teng [1 ]
Liu, Zhanqiang [1 ]
机构
[1] Shandong Univ, Key Lab High Efficiency & Clean Mfg, Jinan 250061, Shandong, Peoples R China
来源
45TH SME NORTH AMERICAN MANUFACTURING RESEARCH CONFERENCE (NAMRC 45) | 2017年 / 10卷
关键词
Titanium; Biomaterials; Corrosion resistance; Surface morphology; polarization; ELECTROCHEMICAL CONSTRUCTION; BONE ATTACHMENT; CELL RESPONSE; ROUGHNESS; BIOACTIVITY; ADHESION; BIOMATERIALS; TOPOGRAPHY; TI-6AL-4V; SUBSTRATE;
D O I
10.1016/j.promfg.2017.07.006
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
As one of vital biomaterials to implants, titanium (Ti) is widely used in the orthopedic and dentistry fields. In order to improve the interaction of biomaterial surfaces with tissues, various surface structures were fabricated by surface medication methods in previous researches. However, the corrosion of biomedical metallic materials is inevitable, and the ions released from their surfaces would lead to toxicity and allergen. Therefore, to achieve satisfied osseointegration, good corrosion resistance is necessary. In this paper, four groups of samples (smooth surface (P), microstructure surface (M), micro/nanostructure surface (MN) and functionalized micro/nanostructure surface (Ag-PDA)) were prepared, and the corrosion behavior of them was evaluated by electrochemical workstation in Ringer's solution. Through comparing to the electrochemical parameters of different samples, the corrosion resistance of the Ag-MN samples is the best, while that of the M samples is the worst. The results showed that treated samples displayed out good corrosion resistance except for M samples and the order of their corrosion resistance was Ag-PDA>MN>P>M. It was indicated that the suitable surface morphologies were important to improve the corrosion resistance of Ti via applying surface modification methods. In particular, the corrosion resistance of Ti would be significantly increased after covering a layer of barrier. (C) 2017 The Authors. Published by Elsevier B.V.
引用
收藏
页码:363 / 370
页数:8
相关论文
共 50 条
  • [21] Effects of HA-Coating on the Surface Morphology and Corrosion Behavior of a Co-Cr-Based Implant in Different Conditions
    H. Kheimehsari
    S. Izman
    Mostafa Rezazadeh Shirdar
    Journal of Materials Engineering and Performance, 2015, 24 : 2294 - 2302
  • [22] Multiform TiO2 nano-network enhances biological response to titanium surface for dental implant applications
    Yang, Wei-En
    Huang, Her-Hsiung
    APPLIED SURFACE SCIENCE, 2019, 471 : 1041 - 1052
  • [23] Nanowire micropattern for manipulating spatially specific cell behavior on titanium implant surface
    Zhu, Xiaojing
    Zhang, Can
    MATERIALS TODAY COMMUNICATIONS, 2023, 34
  • [24] Comparative Investigations on the Bioactivity of Surface Grain Refined Titanium and Surface Oxidized Titanium for Biomedical Implant Applications
    Satyanarayana, Chelamalasetti Pavan
    Raju, Lam Suvarna
    Raju, Lam Ratna
    Dondapati, Sreekanth
    Dumpala, Ravikumar
    Buradagunta, Ratna Sunil
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2022, 13 (04):
  • [25] Fibroblasts and osteoblasts behavior after contact with different titanium surfaces used as implant abutment: An in vitro experimental study
    de Lima, Jose Henrique Cavalcanti
    Robbs, Patricia Cristina Matos
    Tude, Elena Mavropoulos Oliveira
    De Aza, Piedad N.
    da Costa, Eleani Maria
    Scarano, Antonio
    Prados-frutos, Juan Carlos
    Fernandes, Gustavo Vicentis Oliveira
    Gehrke, Sergio Alexandre
    HELIYON, 2024, 10 (03)
  • [26] Titanium abutment surface modifications and peri-implant tissue behavior: a systematic review and meta-analysis
    Canullo, Luigi
    Menini, Maria
    Santori, Gregorio
    Rakic, Mia
    Sculean, Anton
    Pesce, Paolo
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (03) : 1113 - 1124
  • [27] Surface treatment, corrosion behavior, and apatite-forming ability of Ti-45Nb implant alloy
    Gostin, Petre F.
    Helth, Arne
    Voss, Andrea
    Sueptitz, Ralph
    Calin, Mariana
    Eckert, Juergen
    Gebert, Annett
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101B (02) : 269 - 278
  • [28] Corrosion behavior of pure titanium in artificial saliva solution
    Mariano, N. A.
    Oliveira, R. G.
    Fernandes, M. A.
    Rigo, E. C. S.
    MATERIA-RIO DE JANEIRO, 2009, 14 (02): : 878 - U120
  • [29] Corrosion Behavior of Surface-Treated Metallic Implant Materials
    Bormann, Therese
    Phuong Thao Mai
    Gibmeier, Jens
    Sonntag, Robert
    Mueller, Ulrike
    Kretzer, J. Philippe
    MATERIALS, 2020, 13 (09)
  • [30] Producing High Wettable Surface on Pure Titanium Sheets by Shot Peening for Bone Implant Applications
    Satyanarayana, Chelamalasetti Pavan
    Raju, Lam Ratna
    Dumpala, Ravikumar
    Buradagunta, Ratna Sunil
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2022, 12 (05): : 5745 - 5752