Corrosion Behavior of Titanium Implant with different Surface Morphologies

被引:24
作者
Wang, Guisen [1 ]
Wan, Yi [1 ]
Wang, Teng [1 ]
Liu, Zhanqiang [1 ]
机构
[1] Shandong Univ, Key Lab High Efficiency & Clean Mfg, Jinan 250061, Shandong, Peoples R China
来源
45TH SME NORTH AMERICAN MANUFACTURING RESEARCH CONFERENCE (NAMRC 45) | 2017年 / 10卷
关键词
Titanium; Biomaterials; Corrosion resistance; Surface morphology; polarization; ELECTROCHEMICAL CONSTRUCTION; BONE ATTACHMENT; CELL RESPONSE; ROUGHNESS; BIOACTIVITY; ADHESION; BIOMATERIALS; TOPOGRAPHY; TI-6AL-4V; SUBSTRATE;
D O I
10.1016/j.promfg.2017.07.006
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
As one of vital biomaterials to implants, titanium (Ti) is widely used in the orthopedic and dentistry fields. In order to improve the interaction of biomaterial surfaces with tissues, various surface structures were fabricated by surface medication methods in previous researches. However, the corrosion of biomedical metallic materials is inevitable, and the ions released from their surfaces would lead to toxicity and allergen. Therefore, to achieve satisfied osseointegration, good corrosion resistance is necessary. In this paper, four groups of samples (smooth surface (P), microstructure surface (M), micro/nanostructure surface (MN) and functionalized micro/nanostructure surface (Ag-PDA)) were prepared, and the corrosion behavior of them was evaluated by electrochemical workstation in Ringer's solution. Through comparing to the electrochemical parameters of different samples, the corrosion resistance of the Ag-MN samples is the best, while that of the M samples is the worst. The results showed that treated samples displayed out good corrosion resistance except for M samples and the order of their corrosion resistance was Ag-PDA>MN>P>M. It was indicated that the suitable surface morphologies were important to improve the corrosion resistance of Ti via applying surface modification methods. In particular, the corrosion resistance of Ti would be significantly increased after covering a layer of barrier. (C) 2017 The Authors. Published by Elsevier B.V.
引用
收藏
页码:363 / 370
页数:8
相关论文
共 37 条
[31]   Biomaterials with hierarchically defined micro- and nanoscale structure [J].
Tan, J ;
Saltzman, WM .
BIOMATERIALS, 2004, 25 (17) :3593-3601
[32]   Magnesium ion implantation on a micro/nanostructured titanium surface promotes its bioactivity and osteogenic differentiation function [J].
Wang, Guifang ;
Li, Jinhua ;
Zhang, Wenjie ;
Xu, Lianyi ;
Pan, Hongya ;
Wen, Jin ;
Wu, Qianju ;
She, Wenjun ;
Jiao, Ting ;
Liu, Xuanyong ;
Jiang, Xinquan .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2014, 9 :2387-2398
[33]   The effect of nanotopography on calcium and phosphorus deposition on metallic materials in vitro [J].
Ward, BC ;
Webster, TJ .
BIOMATERIALS, 2006, 27 (16) :3064-3074
[34]   Effects of titanium surface topography on bone integration: a systematic review [J].
Wennerberg, Ann ;
Albrektsson, Tomas .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 :172-184
[35]   The effect of anatase TiO2 nanotube layers on MC3T3-E1 preosteoblast adhesion, proliferation, and differentiation [J].
Yu, Wei-qiang ;
Jiang, Xing-quan ;
Zhang, Fu-qiang ;
Xu, Ling .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2010, 94A (04) :1012-1022
[36]   High surface energy enhances cell response to titanium substrate microstructure [J].
Zhao, G ;
Schwartz, Z ;
Wieland, M ;
Rupp, F ;
Geis-Gerstorfer, J ;
Cochran, DL ;
Boyan, BD .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2005, 74A (01) :49-58
[37]   Alignment of osteoblast-like cells and cell-produced collagen matrix induced by nanogrooves [J].
Zhu, BS ;
Lu, QH ;
Yin, J ;
Hu, J ;
Wang, ZG .
TISSUE ENGINEERING, 2005, 11 (5-6) :825-834