Comparison of three videolaryngoscopes: Pentax Airway Scope, C-MAC™, Glidescope® vs the Macintosh laryngoscope for tracheal intubation

被引:76
作者
Teoh, W. H. L. [1 ]
Saxena, S. [2 ]
Shah, M. K. [1 ]
Sia, A. T. H. [1 ]
机构
[1] KK Womens & Childrens Hosp, Dept Womens Anaesthesia, Singapore, Singapore
[2] Minist Hlth Holdings Pte Ltd, Singapore, Singapore
关键词
ENDOTRACHEAL INTUBATION; DIFFICULT LARYNGOSCOPY; VIDEO LARYNGOSCOPE; LARYNGEAL VIEW; OBESE-PATIENTS; STYLET USE; PERFORATION; MANNEQUINS; BLADE; SCORE;
D O I
10.1111/j.1365-2044.2010.06513.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
P>We compared the intubating characteristics of the Pentax Airway Scope, the C-MAC (TM) and the Glidescope (R) with those of the Macintosh laryngoscope in 400 patients without predictors of difficult intubation. We found shorter intubation times with the Airway Scope (mean (SD) 20.6 (11.5) s) compared with the C-MAC (31.9 (17.6) s) and Glidescope (31.2 (15.0) s), p < 0.001. The median (IQR [range]) score for ease of intubation was significantly lower (better) with the Airway Scope (0 (0-8.75 [0-60])) than with the C-MAC (10 (0-20 [0-90])) or Glidescope (0 (0-20 [0-80])), p < 0.001. Ease of blade insertion in the C-MAC (0 (0-0 [0-30])) was superior to that of the Airway Scope (0 (0-0 [0-70])), Macintosh (0 (0-0 [0-80])) or Glidescope (0 (0-10 [0-60])), p = 0.006. More patients had a grade 1 laryngeal view with the Airway Scope (97%) compared with the C-MAC (87%), Glidescope (78%), or Macintosh (58%), p < 0.001. There were no grade 3 laryngeal views with the Airway Scope. The three videolaryngoscopes had comparable first attempt successful intubation rates: 95% for the Airway Scope, 93% for the C-MAC and 91% for the Glidescope.
引用
收藏
页码:1126 / 1132
页数:7
相关论文
共 21 条
[1]   The intubation difficulty scale (IDS) - Proposal and evaluation of a new score characterizing the complexity of endotracheal intubation [J].
Adnet, F ;
Borron, SW ;
Racine, SX ;
Clemessy, JL ;
Fournier, JL ;
Plaisance, P ;
Lapandry, C .
ANESTHESIOLOGY, 1997, 87 (06) :1290-1297
[2]   CRITERIA FOR ESTIMATING LIKELIHOOD OF DIFFICULTY OF ENDOTRACHEAL INTUBATION WITH THE MACINTOSH LARYNGOSCOPE [J].
BELLHOUSE, CP ;
DORE, C .
ANAESTHESIA AND INTENSIVE CARE, 1988, 16 (03) :329-337
[3]   The C-MAC Videolaryngoscope: First Experiences with a New Device for Videolaryngoscopy-Guided Intubation [J].
Cavus, Erol ;
Kieckhaefer, Joerg ;
Doerges, Volker ;
Moeller, Thora ;
Thee, Carsten ;
Wagner, Klaus .
ANESTHESIA AND ANALGESIA, 2010, 110 (02) :473-477
[4]   A new practical classification of laryngeal view [J].
Cook, TM .
ANAESTHESIA, 2000, 55 (03) :274-279
[5]   Perforation of the soft palate using the GlideScope® videolaryngoscope [J].
Cross, Paul ;
Cytryn, Jacalyn ;
Cheng, Kenneth K. .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (07) :588-589
[6]   Comparison of the GlideScope® video laryngoscope vs. the intubating laryngeal mask for females with normal airways [J].
Fun, W. L. L. ;
Lim, Y. ;
Teoh, W. H. L. .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2007, 24 (06) :486-491
[7]   Evaluation of four manikins as simulators for teaching airway management procedures specified in the Difficult Airway Society guidelines, and other advanced airway skills [J].
Jordan, G. M. ;
Silsby, J. ;
Bayley, G. ;
Cook, T. M. .
ANAESTHESIA, 2007, 62 (07) :708-712
[8]   Palatopharyngeal wall perforation during GlideScope® intubation [J].
Leong, W. L. ;
Lim, Y. ;
Sia, A. T. H. .
ANAESTHESIA AND INTENSIVE CARE, 2008, 36 (06) :870-874
[9]   A Comparison of Three Videolaryngoscopes: The Macintosh Laryngoscope Blade Reduces, but Does Not Replace, Routine Stylet Use for Intubation in Morbidly Obese Patients [J].
Maassen, Ralph ;
Lee, Ruben ;
Hermans, Boukje ;
Marcus, Marco ;
van Zundert, Andre .
ANESTHESIA AND ANALGESIA, 2009, 109 (05) :1560-1565
[10]   Anterior tonsillar pillar perforation during Glidescope® video laryngoscopy [J].
Malik, Asif M. ;
Frogel, Jonathan K. .
ANESTHESIA AND ANALGESIA, 2007, 104 (06) :1610-1611