Operating characteristics of a three-stage Stirling pulse tube cryocooler operating around 5 K

被引:13
|
作者
Qiu, L. M. [1 ]
Cao, Q. [1 ]
Zhi, X. Q. [1 ]
Han, L. [1 ]
Gan, Z. H. [1 ]
Yu, Y. B. [1 ]
Liu, Y. [1 ]
Zhang, X. J. [1 ]
Pfotenhauer, J. M. [1 ,2 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Zhejiang, Peoples R China
[2] Univ Wisconsin, Madison, WI 53706 USA
关键词
Pulse tube cryocooler; Three-stage; Operating characteristics;
D O I
10.1016/j.cryogenics.2012.03.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
A Stirling pulse tube cryocooler (SPTC) operating at the liquid-helium temperatures represents an excellent prospect for satisfying the requirements of space applications because of its compactness, high efficiency and reliability. However, the working mechanism of a 4 K SPTC is more complicated than that of the Gifford McMahon (GM) PTC that operates at the relatively low frequency of 1-2 Hz, and has not yet been well understood. In this study, the primary operating parameters, including frequency, charge pressure, input power and precooling temperature, are systematically investigated in a home-developed separate three-stage SPTC. The investigation demonstrates that the frequency and precooling temperature are closely coupled via phase shift. In order to improve the cooling capacity it is important to lower the frequency and the precooling temperature simultaneously. In contrast to the behavior predicted by previous studies, the pressure dependence of the gas properties results in an optimized pressure that decreases significantly as the temperature is lowered. The third stage reaches a lowest temperature of 4.97 K at 29.9 Hz and 0.91 MPa. A cooling power of 25 mW is measured at 6.0 K. The precooling temperature is 23.7 K and the input power is 100 W. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:382 / 388
页数:7
相关论文
共 34 条
  • [21] High efficiency linear compressor driven pulse tube cryocooler operating in liquid nitrogen temperature
    Hu JianYing
    Wang XiaoTao
    Dai Wei
    Luo ErCang
    Huang Yu
    CHINESE SCIENCE BULLETIN, 2009, 54 (23): : 4428 - 4431
  • [22] EXPERIMENTAL STUDIES ON A SINGLE STAGE STIRLING TYPE PULSE TUBE CRYOCOOLER DRIVEN BY OIL-LUBRICATED COMPRESSOR
    Ren, Jia
    Hu Jianying
    Luo Ercang
    Wang Xiaotao
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 52 - +
  • [23] A thermoacoustically-driven pulse tube cryocryocooler operating around 300Hz
    Yu, G. Y.
    Zhu, S. L.
    Dai, W.
    Luo, E. C.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 1659 - 1666
  • [24] Impact of operating parameters on 80 K pulse tube cryocoolers for space applications
    Liu, Shaoshuai
    Jiang, Zhenhua
    Ding, Lei
    Zhu, Haifeng
    Huang, Qi
    Wu, Yinong
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 99 : 226 - 233
  • [25] Influence of frequency and pressure on entropy production characteristics of regenerator at 20 K pulse tube cryocooler
    Zhenhua, Jiang
    Jiantang, Song
    Shaoshuai, Liu
    Wang, Yin
    Haifeng, Zhu
    Yinong, Wu
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 144 : 222 - 230
  • [26] Investigation of DC flow effects on a 4K two-stage pulse tube cryocooler
    Tsuchiya, A.
    Xu, M. Y.
    11TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2013), PTS 1-4, 2014, 507
  • [27] High frequency single-stage multi-bypass pulse tube cryocooler for 23.8K
    Yang, Junling
    Hou, Xiaofeng
    Yang, Luwei
    Zhou, Yuan
    Zhang, Liang
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 1108 - 1113
  • [28] A two-stage thermally-coupled pulse tube cryocooler working at 35 K for space application
    Chao, Yijun
    Wang, Bo
    Li, Haiying
    Xia, Ming
    Zhao, Qinyu
    Wang, Haoren
    Li, Ruize
    Chen, Jun
    Gan, Zhihua
    ACTA ASTRONAUTICA, 2022, 191 : 193 - 203
  • [29] High-efficiency 3 W/40 K single-stage pulse tube cryocooler for space application
    Zhang, Ankuo
    Wu, Yinong
    Liu, Shaoshuai
    Liu, Biqiang
    Yang, Baoyu
    CRYOGENICS, 2018, 90 : 41 - 46
  • [30] Study on high energy efficiency 30 K sigle-stage pulse tube cryocooler for a space infrared detector
    Liu Shao-Shuai
    Jiang Zhen-Hua
    Zhang An-Kuo
    Tang Zhen-Gang
    Ding Lei
    Wu Yi-Nong
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2018, 37 (04) : 403 - 410