Operating characteristics of a three-stage Stirling pulse tube cryocooler operating around 5 K

被引:13
|
作者
Qiu, L. M. [1 ]
Cao, Q. [1 ]
Zhi, X. Q. [1 ]
Han, L. [1 ]
Gan, Z. H. [1 ]
Yu, Y. B. [1 ]
Liu, Y. [1 ]
Zhang, X. J. [1 ]
Pfotenhauer, J. M. [1 ,2 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Zhejiang, Peoples R China
[2] Univ Wisconsin, Madison, WI 53706 USA
关键词
Pulse tube cryocooler; Three-stage; Operating characteristics;
D O I
10.1016/j.cryogenics.2012.03.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
A Stirling pulse tube cryocooler (SPTC) operating at the liquid-helium temperatures represents an excellent prospect for satisfying the requirements of space applications because of its compactness, high efficiency and reliability. However, the working mechanism of a 4 K SPTC is more complicated than that of the Gifford McMahon (GM) PTC that operates at the relatively low frequency of 1-2 Hz, and has not yet been well understood. In this study, the primary operating parameters, including frequency, charge pressure, input power and precooling temperature, are systematically investigated in a home-developed separate three-stage SPTC. The investigation demonstrates that the frequency and precooling temperature are closely coupled via phase shift. In order to improve the cooling capacity it is important to lower the frequency and the precooling temperature simultaneously. In contrast to the behavior predicted by previous studies, the pressure dependence of the gas properties results in an optimized pressure that decreases significantly as the temperature is lowered. The third stage reaches a lowest temperature of 4.97 K at 29.9 Hz and 0.91 MPa. A cooling power of 25 mW is measured at 6.0 K. The precooling temperature is 23.7 K and the input power is 100 W. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:382 / 388
页数:7
相关论文
共 34 条
  • [1] A three-stage Stirling pulse tube cryocooler operating below the critical point of helium-4
    Qiu, L. M.
    Cao, Q.
    Zhi, X. Q.
    Gan, Z. H.
    Yu, Y. B.
    Liu, Y.
    CRYOGENICS, 2011, 51 (10) : 609 - 612
  • [2] Progress on An 8 K gas-coupled three-stage Stirling pulse tube cryocooler
    Fang, Chushu
    Liu, Xuming
    Li, Laifeng
    Zhou, Yuan
    Pan, Changzhao
    CRYOGENICS, 2025, 146
  • [3] A high efficiency Stirling/pulse tube hybrid cryocooler operating at 35 K/85 K
    Liu, Biqiang
    Jiang, Zhenhua
    Ying, Kongkuai
    Zhu, Haifeng
    Liu, Shaoshuai
    Wen, Fengshuo
    Wu, Yinong
    Dong, Deping
    CRYOGENICS, 2019, 101 : 137 - 140
  • [4] Entropy analyses of the three-stage thermally-coupled Stirling-type pulse tube cryocooler
    Gao, Zhiqian
    Dang, Haizheng
    APPLIED THERMAL ENGINEERING, 2016, 100 : 944 - 960
  • [5] Operating characteristics of a single-stage Stirling-type pulse tube cryocooler with high cooling power at liquid nitrogen temperatures
    Sun, Jiu-ce
    Dietrich, Marc
    Qiu, Li-min
    Thummes, Guenter
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2015, 16 (07): : 577 - 585
  • [6] A single-stage GM-type pulse tube cryocooler operating at 10.6 K
    Gan, Z. H.
    Dong, W. Q.
    Qiu, L. M.
    Zhang, X. B.
    Sun, H.
    He, Y. L.
    Radebaugh, R.
    CRYOGENICS, 2009, 49 (05) : 198 - 201
  • [7] Frequency response characteristics of a thermally coupled three-stage Stirling-type pulse tube cryocooler capable of achieving 110 mW@7 K
    Wen, Fengshuo
    Liu, Shaoshuai
    Wu, Wenting
    Song, Jiantang
    Li, Nanxi
    Jiang, Zhenhua
    Wu, Yinong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 145 : 208 - 216
  • [8] A high efficiency coaxial pulse tube cryocooler operating at 60 K
    Wang, Nailiang
    Zhao, Miguang
    Ou, Yangyang
    Zhu, Qianglong
    Wei, Lingjiao
    Chen, Houlei
    Cai, Jinghui
    Liang, Jingtao
    CRYOGENICS, 2018, 93 : 48 - 50
  • [9] A lightweight high-capacity pulse tube cryocooler operating at 80 K
    Wang, Nailiang
    Tang, Qingjun
    Xun, Yuqiang
    Liang, Menglin
    Zhao, Miguang
    Chen, Houlei
    Liang, Jingtao
    CRYOGENICS, 2024, 138
  • [10] Theoretical modeling and experimental verifications of the single-compressor-driven three-stage Stirling-type pulse tube cryocooler
    Haizheng Dang
    Dingli Bao
    Zhiqian Gao
    Tao Zhang
    Jun Tan
    Rui Zha
    Jiaqi Li
    Ning Li
    Yongjiang Zhao
    Bangjian Zhao
    Frontiers in Energy, 2019, 13 : 450 - 463