Development of the poly(methylene blue) modified graphite electrodes for the electrochemical detection of hydrogen sulphide

被引:0
作者
Zlamalova, Magda [1 ,2 ]
Janda, Pavel [1 ]
Nesmerak, Karel [2 ]
机构
[1] ASCR, Dept Electrochem Mat, J Heyrovsky Inst Phys Chem, Vvi, Dolejskova 2155-3, Prague 18223 8, Czech Republic
[2] Charles Univ Prague, Dept Analyt Chem, Prague 12843 2, Czech Republic
来源
PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY" | 2015年
关键词
cyclic voltammetry; electropolymerization; hydrogen sulphide; poly(methylene blue); potentiometry; METHYLENE-BLUE; POLYMERIZATION; BIOSENSORS; OXIDATION; POLYMERS; DEVICES; NADH; FILM;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A comparative study have been undertaken of the electropolymerization and electrochemical properties of deposited electroactive polymer on two different graphite electrode substrates: basal plane highly oriented pyrolytic graphite (HOPG) and pencil-graphite electrode (PGE). Poly(methylene blue) modified electrodes (HOPG/pMB and PGE/pMB) have been prepared by potential cycling in aqueous electrolyte solution containing methylene blue monomer. It has been found that electrochemical properties and electrocatalytic activity of deposited film are greatly influenced by the type of electrode substrate. Developed electrodes have been further investigated as potential sensors for hydrogen sulphide.
引用
收藏
页码:232 / 236
页数:5
相关论文
共 50 条
  • [31] Flow injection analysis of sulphide based on its photoelectrocatalytic oxidation at poly-methylene blue modified glassy carbon electrode
    Dilgin, Yusuf
    Canarslan, Seda
    Ayyildiz, Onder
    Ertek, Bensu
    Nisli, Gurel
    ELECTROCHIMICA ACTA, 2012, 66 : 173 - 179
  • [32] Electrochemical modification of graphite electrodes with poly(4-aminophenol)
    Vieira, Sabrina Nunes
    Ferreira, Lucas Franco
    Franco, Diego Leoni
    Afonso, Andre Santiago
    Goncalves, Rafael Ariza
    Brito-Madurro, Ana Graci
    Madurro, Joao Marcos
    MACROMOLECULAR SYMPOSIA, 2006, 245 : 236 - 242
  • [33] Electrochemical and spectroelectrochemical studies on pyridoxine hydrochloride using a poly(methylene blue) modified electrode
    Tan, L
    Xie, QJ
    Yao, SZ
    ELECTROANALYSIS, 2004, 16 (19) : 1592 - 1597
  • [34] Electrochemical behavior of methylene blue at bare and DNA-modified silver solid amalgam electrodes
    Veronika Svitková
    Vlastimil Vyskočil
    Journal of Solid State Electrochemistry, 2022, 26 : 2491 - 2499
  • [35] Poly(methylene blue)-ternary deep eutectic solvent/Au nanoparticle modified electrodes as novel electrochemical sensors: Optimization, characterization and application
    Abad-Gil, Lucia
    Brett, Christopher M. A.
    ELECTROCHIMICA ACTA, 2022, 434
  • [36] Electrochemical behavior of methylene blue at bare and DNA-modified silver solid amalgam electrodes
    Svitkova, Veronika
    Vyskocil, Vlastimil
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2022, 26 (11) : 2491 - 2499
  • [37] Electrochemical preparation of poly(methylene blue)/graphene nanocomposite thin films
    Ercarikci, Elif
    Dagci, Kader
    Topcu, Ezgi
    Alanyalioglu, Murat
    MATERIALS RESEARCH BULLETIN, 2014, 55 : 95 - 101
  • [38] Electrochemical DNA Sensor Based on Carbon Black-Poly(Methylene Blue)-Poly(Neutral Red) Composite
    Kappo, Dominica
    Shurpik, Dmitry
    Padnya, Pavel
    Stoikov, Ivan
    Rogov, Alexey
    Evtugyn, Gennady
    BIOSENSORS-BASEL, 2022, 12 (05):
  • [39] Methylene Blue/Multiwall Carbon Nanotube Modified Electrode for the Amperometric Determination of Hydrogen Peroxide
    Pena, Roselyn C.
    Bertotti, Mauro
    Brett, Christopher M. A.
    ELECTROANALYSIS, 2011, 23 (10) : 2290 - 2296
  • [40] Poly(methylene blue)-modified thick-film gold electrodes for the electrocatalytic oxidation of NADH and their application in glucose biosensors
    Silber, A
    Hampp, N
    Schuhmann, W
    BIOSENSORS & BIOELECTRONICS, 1996, 11 (03) : 215 - 223