Improved reconstruction method for phase stepping data with stepping errors and dose fluctuations

被引:16
作者
Hashimoto, Koh [1 ]
Takano, Hidekazu [1 ]
Momose, Atsushi [1 ]
机构
[1] Tohoku Univ, Inst Multidisciplinary Res Adv Mat, Aoba Ku, Katahira 2-1-1, Sendai, Miyagi 9808577, Japan
来源
OPTICS EXPRESS | 2020年 / 28卷 / 11期
关键词
ALGORITHM;
D O I
10.1364/OE.385236
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In conventional grating-based X-ray interferometry, it is necessary to repeatedly translate one of the gratings with high accuracy in regular submicron steps and to ensure a constant dose delivery during each step. However, stepping errors and dose fluctuations inevitably occur due to mechanical inaccuracies and/or thermal drift of the interferometer during the stepping process. As a result of these stepping errors and dose fluctuations, the standard reconstruction procedure without considering them causes artifacts in the images as stripes of specific frequencies. In this report, we propose an improved reconstruction method to process phase stepping data with stepping errors and dose fluctuations. The approach can be used to estimate the stepping errors and dose fluctuations, and reconstruct virtually artifact-free images. Based on numerical simulations and experimental data including stepping errors and dose fluctuations, we demonstrate that the proposed method is more effective to other previously reported approaches. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:16363 / 16384
页数:22
相关论文
共 14 条
[1]   X-ray phase-contrast imaging: from pre-clinical applications towards clinics [J].
Bravin, Alberto ;
Coan, Paola ;
Suortti, Pekka .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (01) :R1-R35
[2]   Analysis and correction of bias induced by phase stepping jitter in grating-based X-ray phase-contrast imaging [J].
de Marco, Fabio ;
Marschner, Mathias ;
Birnbacher, Lorenz ;
Noel, Peter ;
Herzen, Julia ;
Pfeiffer, Franz .
OPTICS EXPRESS, 2018, 26 (10) :12707-12722
[3]   Enhanced reconstruction algorithm for moire artifact suppression in Talbot-Lau x-ray imaging [J].
Hauke, Christian ;
Anton, Gisela ;
Hellbach, Katharina ;
Leghissa, Martino ;
Meinel, Felix G. ;
Mertelmeier, Thomas ;
Michel, Thilo ;
Radicke, Marcus ;
Sutter, Sven-Martin ;
Weber, Thomas ;
Ritschl, Ludwig .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (13)
[4]  
Kaeppler S, 2017, J MED IMAGING, V4, DOI 10.1117/1.JMI.4.3.034005
[5]  
Malacara D., 1998, Interferogram Analysis for Optical Testing
[6]   Improved algorithm for processing grating-based phase contrast interferometry image sets [J].
Marathe, Shashidhara ;
Assoufid, Lahsen ;
Xiao, Xianghui ;
Ham, Kyungmin ;
Johnson, Warren W. ;
Butler, Leslie G. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (01)
[7]  
Marschner M., 2016, HELICAL XRAY PHASE C, P1
[8]   Recent advances in X-ray phase imaging [J].
Momose, A .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (9A) :6355-6367
[9]   Phase-sensitive imaging and phase tomography using X-ray interferometers [J].
Momose, A .
OPTICS EXPRESS, 2003, 11 (19) :2303-2314
[10]   Hard-X-ray dark-field imaging using a grating interferometer [J].
Pfeiffer, F. ;
Bech, M. ;
Bunk, O. ;
Kraft, P. ;
Eikenberry, E. F. ;
Broennimann, Ch. ;
Gruenzweig, C. ;
David, C. .
NATURE MATERIALS, 2008, 7 (02) :134-137