A Comprehensive Evaluation of the Precision (Repeatability and Reproducibility) of the Oculus Pentacam HR

被引:184
作者
McAlinden, Colm [1 ]
Khadka, Jyoti
Pesudovs, Konrad
机构
[1] Flinders Med Ctr, Dept Optometry & Vis Sci, Natl Hlth & Med Res Council, Ctr Clin Eye Res, Bedford Pk, SA 5042, Australia
关键词
POSTERIOR CORNEAL SURFACE; NORMAL EYES; SCHEIMPFLUG; THICKNESS; DEPTH; ULTRASOUND; GALILEI; POWER; SHAPE;
D O I
10.1167/iovs.10-7093
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the precision (repeatability and reproducibility) of the Pentacam HR (high-resolution) tomographer (Oculus, Wetzlar, Germany) across a large range of measurement parameters. METHODS. A randomly selected healthy eye of 100 subjects was scanned twice with the Pentacam HR by one observer for each of the three measurement modes: 25-picture (1 second) scan, 50-picture (2 second) scan, and cornea fine scan (50 pictures in 1 second). The repeatability of each scan mode was assessed. One additional 25-picture scan was acquired by a second observer to test reproducibility. RESULTS. Overall, the Pentacam HR had good precision, with the cornea fine scan returning the most precise results. The 25- and 50-picture scans showed similar precision. The repeatability limits, expressed as the within-subject SD x 1.96 root 2 of the anterior keratometry (K)1 and K2 readings with the standard 25-picture scan, were 0.25 and 0.36 D, respectively. Pachymetry maps, corneal maps, anterior chamber depth maps, corneal volume, topometric Q values and indices were also found to be precise. Poor precision was found for estimates of axis (astigmatic and progression index), pupil center pachymetry, single points on corneal maps, refractive power maps, and equivalent K readings. CONCLUSIONS. Measurements taken with the Pentacam HR are repeatable and reproducible, especially those obtained with the cornea fine scan. Although the Pentacam HR is clearly a very useful clinical and research tool, the measurement of corneal axes, pupil center pachymetry, front meridional and axial maps, refractive power maps, and equivalent K readings should be interpreted with caution. (Invest Ophthalmol Vis Sci. 2011;52:7731-7737) DOI:10.1167/iovs.10-7093
引用
收藏
页码:7731 / 7737
页数:7
相关论文
共 19 条
[1]   Correlation between Refractive Error, Corneal Power, and Thickness in a Large Population with a Wide Range of Ametropia [J].
AlMahmoud, Tahra ;
Priest, David ;
Munger, Rejean ;
Jackson, W. Bruce .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) :1235-1242
[2]  
American National Standards Institute. American National Standard Ophthalmics, Z80232007 ANSI AM NA
[3]   Central Ablation Depth and Postoperative Refraction in Excimer Laser Myopic Correction Measured With Ultrasound, Scheimpflug, and Optical Coherence Pachymetry [J].
Arbelaez, Maria Clara ;
Vidal, Camila ;
Mosquera, Samuel Arba .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (08) :699-708
[4]  
Chen S, 2010, ACTA OPHTHALMOL
[5]   Dynamic Analysis of Iris Configuration with Anterior Segment Optical Coherence Tomography [J].
Cheung, Carol Yim-lui ;
Liu, Shu ;
Weinreb, Robert N. ;
Liu, Jing ;
Li, Haitao ;
Leung, Dexter Yu-lung ;
Dorairaj, Syril ;
Liebmann, Jeffrey ;
Ritch, Robert ;
Lam, Dennis Shun Chiu ;
Leung, Christopher Kai-shun .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (08) :4040-4046
[6]   Reproductivity and repeatability of central corneal thickness measurement in keratoconus using the rotating scheimpflug camera and ultrasound pachymetry [J].
De Sanctis, Ugo ;
Missolungi, Alessandro ;
Mutani, Bernardo ;
Richiardi, Lorenzo ;
Grignolo, Federico M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (05) :712-718
[7]   Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation [J].
Doors, Muriel ;
Cruysberg, Lars P. J. ;
Berendschot, Tos T. J. M. ;
de Brabander, John ;
Verbakel, Frenne ;
Webers, Carroll A. B. ;
Nuijts, Rudy M. M. A. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (08) :1139-1146
[8]   Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery [J].
Holladay, Jack T. ;
Hill, Warren E. ;
Steinmueller, Andreas .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (10) :862-868
[9]   Comparison of Corneal Thickness Measurements Using Galilei, HR Pentacam, and Ultrasound [J].
Hosseini, Hamid Reza Jahadi ;
Katbab, Asadollah ;
Khalili, Mohammad Reza ;
Abtahi, Mohammad Bagher .
CORNEA, 2010, 29 (10) :1091-1095
[10]   THE MEAN SHAPE OF THE HUMAN CORNEA [J].
KIELY, PM ;
SMITH, G ;
CARNEY, LG .
OPTICA ACTA, 1982, 29 (08) :1027-1040