Comparison of high efficiency CZT SPECT MPI to coronary angiography

被引:59
|
作者
Duvall, W. Lane [1 ]
Sweeny, Joseph M. [1 ]
Croft, Lori B. [1 ]
Barghash, Maya H. [2 ]
Kulkarni, Nitin K. [2 ]
Guma, Krista A. [1 ]
Henzlova, Milena J. [1 ]
机构
[1] Mt Sinai Med Ctr, Mt Sinai Div Cardiol Mt Sinai Heart, New York, NY 10029 USA
[2] Mt Sinai Med Ctr, Mt Sinai Dept Med, New York, NY 10029 USA
关键词
Myocardial perfusion imaging: SPECT; coronary artery disease; diagnostic and prognostic application; Technetium-99m; Thallium-201; MYOCARDIAL-PERFUSION; HIGH-SPEED; COMPUTED-TOMOGRAPHY; HEART-ASSOCIATION; AMERICAN-COLLEGE; TASK-FORCE; CARDIOLOGY; COMMITTEE;
D O I
10.1007/s12350-011-9382-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The recently introduced cadmium zinc telluride (CZT) SPECT cameras have the potential to reduce radiation exposure to patients and shorten imaging time. So far, there has been only one small study comparing the results of high efficiency CZT SPECT myocardial perfusion imaging (MPI) to invasive coronary angiography. All patients who had either a Tc-99m sestamibi or Tl-201 SPECT MPI study using a CZT camera (GE Discovery NM 530c) over a 1-year period followed by a coronary angiogram within 2 months were included. Only patients with a history of CABG surgery were excluded. Standard stress protocols were employed. Rest images were acquired for 5 min and stress supine and prone images for 3 min each. Both MPI studies and coronary angiograms were interpreted by blinded readers. A standard 17-segment model was employed for MPI interpretation, and coronary angiograms were interpreted for the presence of obstructive epicardial coronary artery disease (CAD) defined as a parts per thousand yen70% luminal narrowing. Correlation was based on the ability to diagnose obstructive epicardial CAD. Of the 3,111 patients who underwent SPECT imaging using the CZT camera during this time period, 230 patients qualified for the correlation study (mean age 64.2 +/- A 11.0 years old, 69% male, and 49% had a history of intracoronary stenting). Tc-99m was used in 76% vs Tl-201 in 24% of the studies. Exercise stress was performed in 60% of patients and vasodilator pharmacologic stress in 40%. Sensitivity was 95%, normalcy rate was 97%, and accuracy was 69% for detecting obstructive CAD. In this so far largest correlation study between coronary angiography and high efficiency CZT SPECT imaging, a high sensitivity and accuracy for detecting obstructive epicardial CAD was found for this new SPECT camera technology.
引用
收藏
页码:595 / 604
页数:10
相关论文
共 50 条
  • [1] Comparison of high efficiency CZT SPECT MPI to coronary angiography
    W. Lane Duvall
    Joseph M. Sweeny
    Lori B. Croft
    Maya H. Barghash
    Nitin K. Kulkarni
    Krista A. Guma
    Milena J. Henzlova
    Journal of Nuclear Cardiology, 2011, 18 : 595 - 604
  • [2] Comparison of High Speed CZT SPECT MPI to Coronary Angiography
    Duvall, William L.
    Sweeny, Joseph
    Croft, Lori
    Barghash, Maya
    Guma, Krista
    Henzlova, Milena
    CIRCULATION, 2010, 122 (21)
  • [3] Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: Comparison to coronary angiography
    Duvall, W. Lane
    Sweeny, Joseph M.
    Croft, Lori B.
    Ginsberg, Eric
    Guma, Krista A.
    Henzlova, Milena J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (01) : 19 - 27
  • [4] High-efficiency SPECT MPI: Comparison of automated quantification, visual interpretation, and coronary angiography
    Duvall, W. Lane
    Slomka, Piotr J.
    Gerlach, Jim R.
    Sweeny, Joseph M.
    Baber, Usman
    Croft, Lori B.
    Guma, Krista A.
    George, Titus
    Henzlova, Milena J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (05) : 763 - 773
  • [5] Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera
    Duvall, W. Lane
    Croft, Lori B.
    Ginsberg, Eric S.
    Einstein, Andrew J.
    Guma, Krista A.
    George, Titus
    Henzlova, Milena J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (05) : 847 - 857
  • [6] Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: Comparison to coronary angiography
    W. Lane Duvall
    Joseph M. Sweeny
    Lori B. Croft
    Eric Ginsberg
    Krista A. Guma
    Milena J. Henzlova
    Journal of Nuclear Cardiology, 2012, 19 : 19 - 27
  • [7] Comparison of 2D-QCA, 3D-QCA and coronary angiography derived FFR in predicting myocardial ischemia assessed by CZT-SPECT MPI
    Tang, Xianglin
    Dai, Neng
    Zhang, BuChun
    Cai, Haidong
    Huo, Yanlei
    Yang, Mengdie
    Jiang, Yongji
    Duan, Shaofeng
    Shen, Jianying
    Zhu, Mengyun
    Xu, Yawei
    Ge, Junbo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (05) : 1973 - 1982
  • [8] The value of local normal limits in quantitative Thallium-201 CZT MPI SPECT
    Gregoire, Bastien
    Pina-Jomir, Geraldine
    Bontemps, Laurence
    Janier, Marc
    Scheiber, Christian
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (02) : 672 - 682
  • [9] Comparison of 2D-QCA, 3D-QCA and coronary angiography derived FFR in predicting myocardial ischemia assessed by CZT-SPECT MPI
    Xianglin Tang
    Neng Dai
    BuChun Zhang
    Haidong Cai
    Yanlei Huo
    Mengdie Yang
    Yongji Jiang
    Shaofeng Duan
    Jianying Shen
    Mengyun Zhu
    Yawei Xu
    Junbo Ge
    Journal of Nuclear Cardiology, 2023, 30 : 1973 - 1982
  • [10] Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera
    W. Lane Duvall
    Lori B. Croft
    Eric S. Ginsberg
    Andrew J. Einstein
    Krista A. Guma
    Titus George
    Milena J. Henzlova
    Journal of Nuclear Cardiology, 2011, 18 : 847 - 857