The use of electrical resistance tomography for the characterization of gas holdup inside a bubble column bioreactor containing activated sludge

被引:42
作者
Babaei, Roghayyeh [1 ]
Bonakdarpour, Babak [1 ]
Ein-Mozaffari, Farhad [2 ]
机构
[1] Amirkabir Univ Technol, Dept Chem Engn, Tehran, Iran
[2] Ryerson Univ, Dept Chem Engn, Toronto, ON, Canada
关键词
Electrical resistance tomography; Activated sludge; Bobble column bioreactors; Gas holdup; Sludge rheology; Mixed Liquor Suspended Solids; COMPUTATIONAL FLUID-DYNAMICS; SUBMERGED MEMBRANE BIOREACTORS; HYDRAULIC RETENTION TIME; WASTE-WATER TREATMENT; MASS-TRANSFER; OXYGEN-TRANSFER; AERATION TANKS; HEAT-TRANSFER; HYDRODYNAMICS; REACTORS;
D O I
10.1016/j.cej.2015.01.042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Gas holdup is a determinant factor regarding the efficiency of the activated sludge processes. Despite the numerous studies on the characterization of gas holdup in two or three phase systems, lack of experimental data in systems including actual cells as the solid phase has been emphasized in the literature. This study is a response to the need for an appropriate knowledge on the gas holdup behavior in the real activated sludge systems. The capabilities of electrical resistance tomography in performing local and global measurements in a non-intrusive manner made it possible to examine the influence of MISS concentration and aeration intensity on the overall as well as spatial distribution of gas holdup within the activated sludge bioreactor. In order to cover all activated sludge processes, a wide range of MISS concentration (0.712-15.86 g/L) was employed, and the effect of MISS on rheological characteristics of the corresponding mixed liquor was measured and modeled. The results of the present study revealed an initially increasing followed by decreasing variation of overall gas holdup with increasing MLSS concentration which is reported in this paper for the first time. Radial distribution of gas holdup was also modeled and the variations of central, wall, and cross sectional average gas holdups with axial location, MLSS, and air velocity were specified. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:260 / 269
页数:10
相关论文
共 33 条
  • [11] Application Study on Bubble Detection in a Metallic Bubble Column Using Electrical Resistance Tomography
    Aw, Suzanna Ridzuan
    Rahim, Ruzairi Abdul
    Rahiman, Mohd Hafiz Fazalul
    Yunus, Fazlul Rahman Mohd
    Fadzil, Naizatul Shima
    Zawahir, Mohd Zikrillah
    Jumaah, Mohd Fahjumi
    Pusppanathan, Muhammad Jaysuman
    Ayub, Nor Muzakkir Nor
    Wahab, Yasmin Abdul
    Bunyamin, Salinda
    JURNAL TEKNOLOGI, 2014, 69 (08):
  • [12] Local bubble parameters in a pressurized gas-liquid bubble column reactor measured by electrical resistance tomography
    Jin, H.-B. (jinhaibo@bipt.edu.cn), 1600, Zhejiang University (27): : 372 - 379
  • [13] Electrical resistance tomography for gas holdup in a gas-liquid stirred tank reactor
    Sardeshpande, Madhavi V.
    Gupta, Suraj
    Ranade, Vivek V.
    CHEMICAL ENGINEERING SCIENCE, 2017, 170 : 476 - 490
  • [14] The investigation of gas holdup distribution in a two-phase bubble column using ultrasonic computed tomography
    Supardan, Muhammad Dani
    Masuda, Yoshifumi
    Maezawa, Akinori
    Uchida, Shigeo
    CHEMICAL ENGINEERING JOURNAL, 2007, 130 (2-3) : 125 - 133
  • [15] Distribution characteristics of holdups in a multi-stage bubble column using electrical resistance tomography
    Jin, Haibo
    Lian, Yicheng
    Qin, Yujian
    Yang, Suohe
    He, Guangxiang
    PARTICUOLOGY, 2013, 11 (02) : 225 - 231
  • [16] Characterisation of a high concentration ionic bubble column using electrical resistance tomography
    Okonkwo, A. D.
    Wang, M.
    Azzopardi, B.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 31 : 69 - 76
  • [17] Application of three-dimensional electrical resistance tomography to characterize gas holdup distribution in laboratory flotation cell
    Kourunen, Jari
    Niitti, Timo
    Heikkinen, Lasse M.
    MINERALS ENGINEERING, 2011, 24 (15) : 1677 - 1686
  • [18] Impacts of dense heat exchanging internals on gas holdup cross-sectional distributions and profiles of bubble column using gamma ray Computed Tomography (CT) for FT synthesis
    Al Mesfer, Mohammed K.
    Sultan, Abbas J.
    Al-Dahhan, Muthanna H.
    CHEMICAL ENGINEERING JOURNAL, 2016, 300 : 317 - 333
  • [19] Distribution characteristics of holdups in a multi-stage bubble column using electrical resistance tomography
    Haibo Jin
    Yicheng Lian
    Yujian Qin
    Suohe Yang
    Guangxiang He
    Particuology, 2013, 11 (02) : 225 - 231
  • [20] The Effect of Sparger Geometry on Gas Bubble Flow Behaviors Using Electrical Resistance Tomography
    靳海波
    R. A. Williams
    ChineseJournalofChemicalEngineering, 2006, (01) : 127 - 131