Background: Fractional exhaled nitric oxide (FeNO) is a surrogate marker for airway inflammation, supporting the diagnostic pathway and treatment decisions for asthma patients. Objectives: Aim of this study was to compare the new analyser Vivatmo pro (Bosch, BV) with NIOX VERO (Circassia, CN) and CLD (Ecomedics, EC). Methods: In 100 asthmatics (median 53 years [range 20-87], 62% female, 86% on inhaled corticosteroids [mean 1,300 mu g beclomethasone dipropionate or equivalent], 35% treated with biologics) 2 FeNO measurements per device were performed. Additionally, the success rate to achieve a valid NO value was evaluated. Results: Sixty-eight percent of the patients had FeNO values below 50 ppb. Median NO concentrations were 31 ppb (range 6-194) for BV, 33 ppb (9-164) for CN and 31ppb (7-353) for EC. Bland-Altman plots suggested an agreement within the predefined limits of +/- 5 ppb for all analysers within the therapeutically relevant range (0-70 ppb). The highest agreement in FeNO levels were between BV and EC with mean differences of -0.26 (95% CI -1.48 to 0.95) vs. 1.52 (95% CI 0.4-2.6) ppb for CN and EC. The results indicate an equivalence of the methods (two-one sided t test-equivalence test: p < 0.0001, +/- 5 ppb margins). Acceptance of the measurements was high for all devices (97%). The highest success rate to obtain 2 valid NO values without failed attempts was achieved with the BV analyser (73 vs. 62% for the CN analyser and 46% for the EC analyser). Conclusions: For the range between 0 and 70 ppb, FeNO concentrations measured with all 3 devices were statistically equivalent within predefined acceptance criteria and did not differ in a clinically relevant way.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] Measurement of exhaled nitric oxide: Comparison of different analysers
    Korn, Stephanie
    Telke, Ina
    Kornmann, Oliver
    Buhl, Roland
    RESPIROLOGY, 2010, 15 (08) : 1203 - 1208
  • [2] Comparison of fractional exhaled nitric oxide (FeNO) levels measured by different analysers
    Saito, Junpei
    Kikuchi, Masami
    Fukuhara, Atsuro
    Sato, Suguru
    Rikimaru, Mami
    Suzuki, Yasuhito
    Uematsu, Manabu
    Togawa, Ryuichi
    Sato, Yuki
    Nikaido, Takefumi
    Tanino, Yoshinori
    Munakata, Mitsuru
    Shibata, Yoko
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [3] A comparison of exhaled nitric oxide measurements performed using three different analysers
    Borrill, Zoe
    Clough, David
    Truman, Nick
    Morris, Julie
    Langley, Stephen
    Singh, Dave
    RESPIRATORY MEDICINE, 2006, 100 (08) : 1392 - 1396
  • [4] Comparison of exhaled nitric oxide analysers
    Müller, KC
    Jörres, RA
    Magnussen, H
    Holz, O
    RESPIRATORY MEDICINE, 2005, 99 (05) : 631 - 637
  • [5] Comparison of Exhaled Nitric Oxide Analysers in Childhood Asthma
    Park, Y. A.
    Lee, J. H.
    Lee, Y. J.
    Song, T. W.
    Kim, K. W.
    Sohn, M. H.
    Kim, K. E.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2011, 127 (02) : AB62 - AB62
  • [6] Measurement of exhaled nitric oxide by three different techniques
    Robbins, RA
    Floreani, AA
    VonEssen, SG
    Sisson, JH
    Hill, GE
    Rubinstein, I
    Townley, RG
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (05) : 1631 - 1635
  • [7] A comparison of two analysers measuring exhaled nitric oxide concentration
    Tomalak, Waldemar
    Radlinski, Jakub
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [8] Measurement of exhaled nitric oxide: comparison of 3 different analyzers
    Korn, Stephanie
    Wilk, Maike
    Voigt, Stefanie
    Keller, Thomas
    Buhl, Roland
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [9] Measurement of Fractional Exhaled Nitric Oxide in Adults: Comparison of Two Different Analyzers (NIOX VERO and NObreath)
    Kang, Sung-Yoon
    Lee, Sang Min
    Lee, Sang Pyo
    TUBERCULOSIS AND RESPIRATORY DISEASES, 2021, 84 (03) : 182 - 187
  • [10] Is Fractional Exhaled Nitric Oxide measurement relevant in Athletes?
    Oliveira, J.
    Dias, H.
    Nagle, M.
    Navarro, S.
    Mulgrew, A.
    Jahangir, A.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2021, 190 (SUPPL 1) : S55 - S55