Setup verification and in vivo dosimetry during intraoperative radiation therapy (IORT) for prostate cancer

被引:23
作者
Soriani, Antonella
Landoni, Valeria
Marzi, Simona
Laccarino, Giuseppe
Saracino, Biancamaria
Arcangeli, Giorgio
Benassi, Marcello
机构
[1] Ist Regina Elena, Lab Med Phys, I-00144 Rome, Italy
[2] Ist Regina Elena, Div Radiotherapy, I-00144 Rome, Italy
关键词
IORT; in vivo dosimetry; MOSFET; prostate therapy;
D O I
10.1118/1.2750965
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to check the setup and dose delivered to the patients during intraoperative electron beam radiation therapy (IORT) for prostate cancer. Twenty eight patients underwent IORT after radical prostatectomy for prostate cancer by means of a dedicated mobile accelerator, Novac7 (by Hitesys, SpA, Italy). A 9 MeV electron beam at high dose per pulse was used. Eighteen patients received IORT at escalating doses of 16, 18, and 20 Gy at 85% isodose, six patients for each dose level. Further, ten patients received 20 Gy at 85% isodose. The electron applicator position was checked in all cases by means of two orthogonal images obtained with brilliance intensifier. Target and organ at risk doses were measured in vivo by a MOSFETs dosimetry system. MOSFETs and microMOSFET dosimeters were inserted into sterile catheters and directly positioned into the rectal lumen, for ten patients, and into the bladder to urethra anastomosis, in the last 14 cases. Verification at 0 degrees led to very few adjustments of setup while verifications at 90 degrees often suggested to bring the applicator closer to the target. In vivo dosimetry showed an absorbed dose into the rectum wall :51% of the total dose. The average dose value inside the anastomosis, for the 12 patients analyzed, was 23.7 Gy with a standard deviation of +/- 7.6%, when the prescription was 20 Gy at 85% isodose. Using a C-arm mobile image intensifier, it is possible to assess if the positioning is correct and safe. Radio-opaque clips and liquid were necessary to obtain good visible images. In vivo MOSFETs dosimetry is feasible and reliable. A satisfactory agreement between measured and expected doses was found. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3205 / 3210
页数:6
相关论文
共 22 条
[1]   Intraoperative radiation therapy using mobile electron linear accelerators: Report of AAPM radiation therapy committee task group no. 72 [J].
Beddar, A. Sam ;
Biggs, Peter J. ;
Chang, Sha ;
Ezzell, Gary A. ;
Faddegon, Bruce A. ;
Hensley, Frank W. ;
Mills, Michael D. .
MEDICAL PHYSICS, 2006, 33 (05) :1476-1489
[2]   Real-time in vivo dosimetry using micro-MOSFET detectors during intraoperative electron beam radiation therapy in early-stage breast cancer [J].
Ciocca, M ;
Piazzi, V ;
Lazzari, R ;
Vavassori, A ;
Luini, A ;
Veronesi, P ;
Galimberti, V ;
Intra, M ;
Guido, A ;
Tosi, G ;
Veronesi, U ;
Orecchia, R .
RADIOTHERAPY AND ONCOLOGY, 2006, 78 (02) :213-216
[3]   In vivo dosimetry using radiochromic films during intraoperative electron beam radiation therapy in early-stage breast cancer [J].
Ciocca, M ;
Orecchia, R ;
Garibaldi, C ;
Rondi, E ;
Luini, A ;
Gatti, G ;
Intra, M ;
Veronesi, P ;
Lazzari, R ;
Tosi, G ;
Veronesi, U .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :285-289
[4]   Local recurrence after radical prostatectomy: Characteristics in size, location, and relationship to prostate-specific antigen and surgical margins [J].
Connolly, JA ;
Shinohara, K ;
Presti, JC ;
Carroll, PR .
UROLOGY, 1996, 47 (02) :225-231
[5]   In vivo dosimetry with MOSFETS: Dosimetric characterization and first clinical results in intraoperative radiotherapy [J].
Consorti, R ;
Petrucci, A ;
Fortunato, F ;
Soriani, A ;
Marzi, S ;
Iaccarino, G ;
Landoni, V ;
Benassi, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (03) :952-960
[6]   Ion recombination correction for very high dose-per-pulse high-energy electron beams [J].
Di Martino, F ;
Giannelli, M ;
Traino, AC ;
Lazzeri, M .
MEDICAL PHYSICS, 2005, 32 (07) :2204-2210
[7]   Is α/β for prostate tumors really low? [J].
Fowler, J ;
Chappell, R ;
Ritter, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (04) :1021-1031
[8]  
*I SUP SAN, 2003, 031 ISTISAN EN
[9]  
IAEA, 2001, 398 IAEA TRS
[10]   Absolute dose measurements by means of a small cylindrical ionization chamber for very high dose per pulse high energy electron beams [J].
Karaj, E. ;
Righi, S. ;
Di Martino, F. .
MEDICAL PHYSICS, 2007, 34 (03) :952-958