Evaluation of a portable Fourier transform infrared gas analyzer for measurements of air toxics in pollution prevention research

被引:9
|
作者
Wright, RS [1 ]
Howe, GB [1 ]
Jayanty, RKM [1 ]
机构
[1] Res Triangle Inst, Ctr Environm Measurements & Qual Assurance, Environm Methods & Stand Dept, Res Triangle Pk, NC 27709 USA
来源
关键词
D O I
10.1080/10473289.1998.10463764
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A portable Fourier transform infrared gas analyzer with a photoacoustic detector performed reliably during pollution prevention research at two industrial facilities. It exhibited good agreement (within approximately 6%) with other analytical instruments (dispersive infrared and flame ionization) when analyte concentrations were high and relatively steady. It did not show good agreement when analyte concentrations were low (approximately 10 parts per million [ppm]) or were varying rapidly (less than 1.5 min). The precision for total acetates measurements was estimated to be approximately 40 ppm for measurements in the 0- to 700-ppm region. The precision for styrene measurements was estimated to be approximately 10 ppm for measurements in the 0- to 90-ppm region.
引用
收藏
页码:1077 / 1084
页数:8
相关论文
共 50 条
  • [1] Portable Gas Analyzer Based on Fourier Transform Infrared Spectrometer for Patrolling and Examining Gas Exhaust
    Liang, Yuntao
    Tang, Xiaojun
    Zhang, Xuliang
    Tian, Fuchao
    Sun, Yong
    Dong, Haozhe
    JOURNAL OF SPECTROSCOPY, 2015, 2015
  • [2] Measurements of natural surface emissivity with portable Fourier transform infrared spectroradiometer
    Tang, Bo-Hui
    Wang, Jie
    Li, Zhao-Liang
    Wu, Hua
    Tang, Ronglin
    INTERNATIONAL CONFERENCE ON INTELLIGENT EARTH OBSERVING AND APPLICATIONS 2015, 2015, 9808
  • [3] Portable Fourier transform infrared spectroradiometer for field measurements of radiance and emissivity
    Korb, AR
    Dybwad, P
    Wadsworth, W
    Salisbury, JW
    APPLIED OPTICS, 1996, 35 (10): : 1679 - 1692
  • [4] Portable Fourier transform infrared spectroradiometer for field measurements of radiance and emissivity
    Morton K. Blaustein Dept. Earth P., Johns Hopkins University, North Charles Street, Baltimore, MD 21218, United States
    不详
    不详
    Appl. Opt., 10 (1679-1692):
  • [5] REMOTE FOURIER-TRANSFORM INFRARED AIR-POLLUTION STUDIES
    HERGET, WF
    BRASHER, JD
    OPTICAL ENGINEERING, 1980, 19 (04) : 508 - 514
  • [6] Portable Fourier transform infrared spectrometer for use as a gas analyser in industrial hygiene
    Ahonen, I
    Riipinen, H
    Roos, A
    ANALYST, 1996, 121 (09) : 1253 - 1255
  • [7] Contributions of Fourier transform infrared spectroscopy in microplastic pollution research: A review
    Veerasingam, S.
    Ranjani, M.
    Venkatachalapathy, R.
    Bagaev, Andrei
    Mukhanov, Vladimir
    Litvinyuk, Daria
    Mugilarasan, M.
    Gurumoorthi, K.
    Guganathan, L.
    Aboobacker, V. M.
    Vethamony, P.
    CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2021, 51 (22) : 2681 - 2743
  • [8] Evaluation of bacterial wood degradation by Fourier Transform Infrared (FTIR) measurements
    Gelbrich, Jana
    Mai, Carsten
    Militz, Holger
    JOURNAL OF CULTURAL HERITAGE, 2012, 13 (03) : S135 - S138
  • [9] MOBILE FOURIER-TRANSFORM INFRARED-SPECTROSCOPY MONITORING OF AIR-POLLUTION
    HAUS, R
    SCHAFER, K
    BAUTZER, W
    HELAND, J
    MOSEBACH, H
    BITTNER, H
    EISENMANN, T
    APPLIED OPTICS, 1994, 33 (24): : 5682 - 5689
  • [10] EXTRACTIVE AND OPEN PATH FOURIER-TRANSFORM INFRARED-SPECTROSCOPY WITH CONVENTIONAL SAMPLING FOR AIR TOXICS EXPOSURE ASSESSMENT
    WINEGAR, ED
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 206 - ENVR