Comparative analysis of imaging techniques for diagnostic accuracy of peri-implant bone defects: a meta-analysis

被引:42
|
作者
Lima Bohner, Lauren Oliveira [1 ,2 ]
Mukai, Eduardo [3 ]
Oderich, Elisa [4 ]
Porporatti, Andre Luis [5 ]
Pacheco-Pereira, Camila [6 ]
Tortamano, Pedro [1 ]
Canto, Graziela De Luca [5 ,6 ]
机构
[1] Univ Sao Paulo, Dept Prosthodont, Sao Paulo, SP, Brazil
[2] Rhein Westfal TH Aachen, Dept Prosthodont, Aachen, Germany
[3] Paulista Dent Surg Assoc APCD, Dept Implantol, Sao Paulo, SP, Brazil
[4] Univ Fed Santa Catarina, Dept Dent, Florianopolis, SC, Brazil
[5] Univ Fed Santa Catarina, Dept Dent, Brazilian Ctr Evidence Based Res, Florianopolis, SC, Brazil
[6] Univ Alberta, Sch Dent, Fac Med & Dent, Edmonton, AB, Canada
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2017年 / 124卷 / 04期
关键词
BEAM COMPUTED-TOMOGRAPHY; FIELD-OF-VIEW; DENTAL IMPLANTS; BUCCAL BONE; IN-VITRO; RADIOGRAPHIC DIAGNOSIS; PERIAPICAL RADIOGRAPHY; THICKNESS; LEVEL; RELIABILITY;
D O I
10.1016/j.oooo.2017.06.119
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The aim of this study was to systematically review the literature regarding diagnostic accuracy of imaging techniques in detecting peri-implant bone defects. Study Design. The search was performed in 8 electronic databases from April to May 2016 and updated in September 2016. Studies that assessed imaging techniques to detect peri-implant bone defects were analyzed. Results. The search yielded 680 articles published from 1991 to 2016. Of these, 12 studies were considered eligible for this review. The selected studies evaluated the use of cone beam computed tomography (CBCT), intraoral radiography (IR), computed tomography, and panoramic radiography. The sensitivity for CBCT was 59%, whereas the specificity was 67%. For IR, the sensitivity was 60%, and the specificity was 59%. Area under the curve values in receiver operating characteristic (ROC) analysis were 69% for CBCT and 63% for IR. For CBCT, the highest value for positive predictive value was 0.94, negative predictive value was 0.98, positive likelihood ratio was 21.3, and negative likelihood ratio was 1.28. For IR, the highest positive predictive value was 1.0, negative predictive value 1.0, positive likelihood ratio 50.0, and negative likelihood ratio 0.70. The highest diagnostic odds ratio was 80 for CBCT and 4.45 for IR. No conclusion could be drawn for additional techniques. Conclusions. Both CBCT and IR showed a clinically acceptable performance for assessing peri-implant bone defects.
引用
收藏
页码:432 / +
页数:14
相关论文
共 50 条
  • [1] Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis
    Chagas, Mariana Murai
    Kobayashi-Velasco, Solange
    Gimenez, Thais
    Paraiso Cavalcanti, Marcelo Gusmao
    IMAGING SCIENCE IN DENTISTRY, 2021, 51 (04) : 363 - 372
  • [2] Assessment of Peri-implant Buccal Bone Thickness Using Digital Imaging Techniques: A Systematic Review and Meta-analysis
    Bohner, Lauren
    Hanisch, Marcel
    Chilvarquer, Israel
    Kleinheinz, Johannes
    Tortamano, Pedro
    OPEN DENTISTRY JOURNAL, 2020, 14 : 150 - 160
  • [3] Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri-implant bone defects
    Song, Dandan
    Shujaat, Sohaib
    Vasconcelos, Karla de Faria
    Huang, Yan
    Politis, Constantinus
    Lambrichts, Ivo
    Jacobs, Reinhilde
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [4] ACCURACY OF HIGH-FREQUENCY ULTRASOUND SCANNER IN DETECTING PERI-IMPLANT BONE DEFECTS
    Bohner, Lauren
    Habor, Daniel
    Gremse, Felix
    Tortamano, Pedro
    Wolfart, Stefan
    Marotti, Juliana
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (03) : 650 - 659
  • [5] Platform-Switching to Preserve Peri-Implant Bone: A Meta-Analysis
    Aslam, Ayesha
    Ahmed, Bilal
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2016, 26 (04): : 315 - 319
  • [6] The feasibility of ultrasonography for the measurement of periodontal and peri-implant phenotype: A systematic review and meta-analysis
    Fan, Shengchi
    Saenz-Ravello, Gustavo
    Al-Nawas, Bilal
    Schiegnitz, Eik
    Diaz, Leonardo
    Sagheb, Keyvan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (05) : 892 - 909
  • [7] In vitro diagnostic accuracy of low-dose CBCT for evaluation of peri-implant bone lesions
    Schwindling, Franz Sebastian
    Hilgenfeld, Tim
    Weber, Dorothea
    Kosinski, Matthias Adalbert
    Rammelsberg, Peter
    Tasaka, Akinori
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (12) : 1200 - 1208
  • [8] The influence of vertical ridge augmentation techniques on peri-implant bone loss: A systematic review and meta-analysis
    Cucchi, Alessandro
    Maiani, Francesco
    Franceschi, Debora
    Sassano, Michele
    Fiorino, Antonino
    Urban, Istvan A.
    Corinaldesi, Giuseppe
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (01) : 15 - 65
  • [9] Outcome of supportive peri-implant therapy on the rates of peri-implant diseases and marginal bone loss: a systematic review and meta-analysis
    Atieh, Momen A.
    AlAli, Fawaghi
    Alsabeeha, Nabeel H. M.
    QUINTESSENCE INTERNATIONAL, 2021, 52 (02): : 122 - 131
  • [10] Bone tissue engineering in oral peri-implant defects in preclinical in vivo research: A systematic review and meta-analysis
    Shanbhag, Siddharth
    Pandis, Nikolaos
    Mustafa, Kamal
    Nyengaard, Jens R.
    Stavropoulos, Andreas
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2018, 12 (01) : E336 - E349