Fetal oxygen saturation and uterine contractions during labor

被引:11
作者
East, CE [1 ]
Dunster, KR [1 ]
Colditz, PB [1 ]
机构
[1] Royal Brisbane Hosp, Royal Womens Hosp, Perinatal Res Ctr, Brisbane, Qld 4029, Australia
关键词
fetus; pulse oximetry; intrapartum monitoring; contractions;
D O I
10.1055/s-2007-993955
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Oxygen availability to the fetus during uterine contractions has not been widely reported. We examined whether fetal oxygen saturation (FSpO(2)) values and signal quality (SQ) were affected by uterine contractions. An intrauterine pressure catheter and a Nellcor FS14 fetal oxygen saturation sensor (Nellcor Puritan Bennett Inc., Pleasanton, CA) were placed transvaginally during the first stage of 17 labors. Fetal SpO(2) and SQ units were recorded on a beat-to-beat basis and 10 sec averages of the data calculated over 25 contractions per patient. Five epochs were determined: (1) 30 sec prior to a contraction; (2) during a contraction; (3)50 sec following completion of a contraction; (4) noncontraction periods, excluding epochs 1 or 3; and (5) equivocal, that is, overlap of epochs 1-3. Mean FSpO(2) was lowest during epoch 3 (45.0) and highest during epoch 2 (47.3%) (p < 0.001). This small difference is unlikely to be of any clinical significance, however. Mean signal quality was lowest in epoch 1 (42.8 units) and highest in epoch 4 (48.0 units) (p < 0.05), that is, in noncontraction periods. We conclude that FSpO(2) and SQ were unaffected by uterine contractions.
引用
收藏
页码:345 / 349
页数:5
相关论文
共 14 条
[1]  
*ACOG, 1995, ACOG TECHN B, V207, P1
[2]   Fetal heart rate changes and cerebral oxygenation measured by near-infrared spectroscopy during the first stage of labour [J].
Aldrich, CJ ;
DAntona, D ;
Spencer, JAD ;
Delpy, DT ;
Reynolds, EOR ;
Wyatt, JS .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1996, 64 (02) :189-195
[3]   Fetal oxygen saturation monitoring in labour: An analysis of 118 cases [J].
East, CE ;
Dunster, KR ;
Colditz, PB ;
Nath, CE ;
Earl, JW .
AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1997, 37 (04) :397-401
[4]   Human fetal intrapartum oxygen saturation monitoring: Agreement between readings from two sensors on the same fetus [J].
East, CE ;
Colditz, PB ;
Dunster, KR ;
Khoo, SK .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 174 (05) :1594-1598
[5]   ARTIFACTS IN FETAL PULSE OXIMETRY - INCOMPLETE SENSOR-TO-SKIN CONTACT [J].
GARDOSI, JO ;
DAMIANOU, D ;
SCHRAM, CMH .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 170 (04) :1169-1173
[6]  
GARDOSI JO, 1989, LANCET, P692
[7]   THE EFFECT OF OXYTOCIN-INDUCED HYPERSTIMULATION ON FETAL OXYGEN [J].
JOHNSON, N ;
VANOUDGAARDEN, E ;
MONTAGUE, I ;
MCNAMARA, H .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1994, 101 (09) :805-807
[8]   Fetal pulse oximetry [J].
Luttkus, AK ;
Dudenhausen, JW .
BAILLIERES CLINICAL OBSTETRICS AND GYNAECOLOGY, 1996, 10 (02) :295-306
[9]   Physio-optical considerations in the design of fetal pulse oximetry sensors [J].
Mannheimer, PD ;
Fein, ME ;
Casciani, JR .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 :S9-S19
[10]  
MARSAL K, 1992, FETAL NEONATAL PHYSL, V1, P703