Reactive Power Control Strategy of DFIG Wind Farms for Regulating Voltage of Power Grid

被引:0
作者
Zhai, Jingjing [1 ]
Liu, Haoming [1 ]
机构
[1] Nanjing Inst Technol, Sch Elect Power Engn, Nanjing, Jiangsu, Peoples R China
来源
2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION | 2014年
关键词
Doubly-fed induction generator (DFIG); reactive power control; voltage control; power limitation; MANAGEMENT;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
If a wind farm is weakly connected to a power grid, then the voltage of the connection point fluctuates frequently due to the changeable wind speed. The active and reactive power of a doubly-fed induction generator (DFIG) can be decoupling controlled and the grid-side converter (GSC) of a DFIG can also generate some reactive power by adjusting the power factor, thus a DFIG can be considered as a reactive power resource to stabilize the voltage of the connection bus. Based on the power relationship of a DFIG, the up and down reactive power limitations of DFIG stator and GSC are analyzed. Then a reactive power control strategy of a DFIG wind farm is proposed, in which, a certain number of DFIGs are selected to support reactive power to the power grid when the voltage of the connection point drops. The control strategy aims at bringing the reactive power capability of DFIG into play and cutting down the investments in the reactive power compensation devices which are used less. The simulation model of a grid-connected DFIG wind farm is developed on the PSCAD/EMTDC platform, and the simulation results demonstrate the effectiveness of the control strategy proposed.
引用
收藏
页数:5
相关论文
共 10 条
[1]   Coordinated reactive power management in power networks with wind turbines and FACTS devices [J].
Amaris, Hortensia ;
Alonso, Monica .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (07) :2575-2586
[2]  
[Anonymous], P IEEE INT S CONS EL
[3]   A secondary voltage control strategy for transmission level interconnection of wind generation [J].
El Moursi, Mohammed ;
Joos, Geza ;
Abbey, Chad .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (03) :1178-1190
[4]   Optimal tracking secondary voltage control for the DFIG wind turbines and compensator devices [J].
El Moursi, Mohammed ;
Joos, Geza .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (12) :1705-1716
[5]   Comparative study on the performance of control systems for doubly fed induction generator (DFIG) wind turbines operating with power regulation [J].
Fernandez, L. M. ;
Garcia, C. A. ;
Jurado, F. .
ENERGY, 2008, 33 (09) :1438-1452
[6]  
Jingmei Fang, 2011, 2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT 2011), P1709, DOI 10.1109/DRPT.2011.5994173
[7]   Reactive power control strategies for DFIG-based plants [J].
Kayikci, Mustafa ;
Milanovic, Jovica V. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (02) :389-396
[8]  
Qiao Ying, 2010, Automation of Electric Power Systems, V34, P96
[9]   Dynamic Model and Control of DFIG Wind Energy Systems Based on Power Transfer Matrix [J].
Rezaei, Esmaeil ;
Tabesh, Ahmadreza ;
Ebrahimi, Mohammad .
IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (03) :1485-1493
[10]   Proportional-integral regulator-based approach to wind farm reactive power management for secondary voltage control [J].
Tapia, Gerardo ;
Tapia, Arantxa ;
Ostolaza, J. Xabier .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (02) :488-498