A review of previous studies on dam leakage based on distributed optical fiber thermal monitoring technology

被引:8
|
作者
Fang, Xiao [1 ]
Zeng, Yajie [2 ]
Xiong, Feng [3 ]
Chen, Jiang [3 ]
Cheng, Fei [4 ]
机构
[1] Sichuan Univ, Coll Architecture & Environm, MOE Key Lab Deep Earth Sci & Engn, Chengdu, Peoples R China
[2] Sichuan Univ, Coll Architecture & Environm, Chengdu, Peoples R China
[3] Sichuan Univ, Coll Architecture & Environm, MOE Key Lab Deep Earth Sci & Engn, Chengdu, Peoples R China
[4] Sichuan Univ, Coll Biomass Sci & Engn, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
Sensors; Fiber optic sensors; Wireless sensor networks; Distributed optical fiber; Dam; Seepage monitoring; Temperature tracing method; RECENT PROGRESS; SEEPAGE; SENSORS; STREAM; DEPENDENCE; SAPPHIRE; CIVIL; HEAT;
D O I
10.1108/SR-02-2021-0068
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Purpose Seepage of the dam is an important safety problem, which may cause internal erosion of the structure. In the field of seepage monitoring in civil engineering, the distributed optical fiber sensing technology based on the temperature tracing method has been paid more attention due to its unique advantages of high sensitivity, good stability and high resolution. The purpose of this paper is to make a review of the existing related research, so as to facilitate the later scholars to understand and further study more systematically. Design/methodology/approach In this paper, three kinds of commonly used distributed fiber temperature measurement technologies are introduced. Based on the working principle, monitoring system, theoretical analysis, experimental research and engineering application of the fiber seepage monitoring technology, the present situation of dam seepage monitoring based on distributed fiber is reviewed in detail and their advantages and disadvantages are compared. Findings The thermal monitoring technology of seepage measurement depends on the accuracy of optical fiber temperature measurement (including the accuracy of the system and the rationality of the discrimination method), the correct installation of optical fiber and the quantitative analysis of temperature data. The accuracy of the current monitoring system can basically meet the existing measurement requirements, but the correct installation of optical fiber and the calibration of temperature data need to be further studied for different discrimination methods, and this field has great research value. Originality/value At present, there are many applications and research studies of optical fiber sensing in the field of structural health monitoring, and there are also reviews of related aspects. However, there is little or no review only in the field of seepage monitoring. This paper summarizes the research and application of optical fiber sensing in the field of seepage monitoring. The possibility of the gradient method to find its new prospect with the development of monitoring systems and the improvement of temperature resolution is discussed. The idea of extending the seepage monitoring method based on distributed optical fiber thermal monitoring technology to other monitoring fields is also given in the paper.
引用
收藏
页码:350 / 360
页数:11
相关论文
共 50 条
  • [41] Monitoring of Reinforcement Steel Corrosion Based on OFDR Distributed Optical Fiber
    Tian H.
    Tang F.
    Li H.
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2020, 23 (06): : 1524 - 1530
  • [42] Monitoring Rutting Deformation of Asphalt Using Distributed Optical Fiber Shape Sensing Technology
    Zhang J.-W.
    Ma X.-Y.
    Zhao H.
    Liu Z.-Y.
    Dong Z.-J.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2023, 36 (03): : 98 - 107
  • [43] Research on distributed optical fiber sensing technology for power pipe corridor breakdown monitoring
    Fan J.
    Huang M.
    Wang Y.
    Yong M.
    Lü L.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2024, 32 (10): : 1433 - 1442
  • [44] Application research of distributed optical fiber sensing technology in nuclear island safety monitoring
    Li Ruiyan
    Yang Xiaojun
    Du Rui
    Kong Lingbing
    Pan Liang
    Mei Ying
    GLOBAL INTELLIGENT INDUSTRY CONFERENCE 2020, 2021, 11780
  • [45] Shield tunnel leakage detection using distributed optical fiber
    Liu, Pengfei
    Ma, Minglei
    Wang, Jianxiu
    Long, Yanxia
    Cao, Ansheng
    Li, Huboqiang
    GEOSHANGHAI INTERNATIONAL CONFERENCE 2024, VOL 8, 2024, 1337
  • [46] Distributed Optical Fiber Sensors Based on Optical Frequency Domain Reflectometry: A review
    Ding, Zhenyang
    Wang, Chenhuan
    Liu, Kun
    Jiang, Junfeng
    Yang, Di
    Pan, Guanyi
    Pu, Zelin
    Liu, Tiegen
    SENSORS, 2018, 18 (04)
  • [47] Developments in distributed optical fiber detection technology
    Ye, Wei
    Zhu, Qianxia
    You, Tianrong
    INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: LASER AND OPTICAL MEASUREMENT TECHNOLOGY; AND FIBER OPTIC SENSORS, 2014, 9297
  • [48] Structural Deformation Monitoring of Flight Vehicles Based on Optical Fiber Sensing Technology: A Review and Future Perspectives
    Lianqing Zhu
    Guangkai Sun
    Weimin Bao
    Zheng You
    Fanyong Meng
    Mingli Dong
    Engineering, 2022, 16 (09) : 39 - 55
  • [49] Structural Deformation Monitoring of Flight Vehicles Based on Optical Fiber Sensing Technology: A Review and Future Perspectives
    Zhu, Lianqing
    Sun, Guangkai
    Bao, Weimin
    You, Zheng
    Meng, Fanyong
    Dong, Mingli
    ENGINEERING, 2022, 16 : 39 - 55
  • [50] Truly Distributed Optical Fiber Sensors for Structural Health Monitoring: From the Telecommunication Optical Fiber Drawling Tower to Water Leakage Detection in Dikes and Concrete Structure Strain Monitoring
    Henault, Jean-Marie
    Moreau, Gautier
    Blairon, Sylvain
    Salin, Jean
    Courivaud, Jean-Robert
    Taillade, Frederic
    Merliot, Erick
    Dubois, Jean-Philippe
    Bertrand, Johan
    Buschaert, Stephane
    Mayer, Stefan
    Delepine-Lesoille, Sylvie
    ADVANCES IN CIVIL ENGINEERING, 2010, 2010