Electrical Performance of Composite Insulators under Icing Conditions

被引:24
作者
Yin, Fanghui [1 ,2 ,3 ]
Jiang, Xingliang [1 ]
Farzaneh, Masoud [2 ,3 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Coll Elect Engn, Chongqing 400044, Peoples R China
[2] Univ Quebec Chicoutimi, NSERC Hydroquebec UQAC Ind Chair Atmospher Icing, Chicoutimi, PQ, Canada
[3] Univ Quebec Chicoutimi, Canada Res Chair Engn Power Network Atmospher Ici, Chicoutimi, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Composite insulator; Shed configuration; Icing flashover; energized icing; AC FLASHOVER PERFORMANCE; STATION INSULATORS; ICE; SELECTION; RESPECT; VOLTAGE; SNOW;
D O I
10.1109/TDEI.2014.004571
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to the substantial advantage compared to porcelain and glass insulators, Composite insulators have been widely accepted in electric power utilities worldwide. Compared with porcelain and glass insulators, the flashover performance of composite insulators is superior under the contaminated condition, whereas their icing flashover performance should be investigated further. As shown in previous studies, many factors influence the flashover performance of composite insulators under icing conditions. In order to figure out the factors that influence the flashover performance of insulators, experiments were carried out on ice-covered energized and de-energized composite insulators under icing condition. The results show that the flashover performances of composite insulators are superior under energized condition compared with de-energized condition. Under energized condition, when icing is light, the flashover performance of different shed configurations is decided by creepage distance. When icing is moderate, the flashover performance of insulator is influenced by water freezing conductivity, shed configuration, creepage factor, and so on. When icing is heavy, most of the sheds are bridged and the configuration of the last few sheds near the high voltage end have important effect on the flashover performance.
引用
收藏
页码:2584 / 2593
页数:10
相关论文
共 34 条
[11]   Selection of station insulators with respect to ice and snow - Part II: methods of selection and options for mitigation [J].
Farzaneh, M ;
Baker, T .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (01) :271-277
[12]   AC FLASHOVER PERFORMANCE OF INSULATORS COVERED WITH ARTIFICIAL ICE [J].
FARZANEH, M ;
DRAPEAU, JF .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) :1038-1051
[13]   Insulator icing test methods and procedures a position paper prepared by the IEEE task force on insulator icing test methods [J].
Farzaneh, M ;
Baker, T ;
Bernstorf, A ;
Brown, K ;
Chisholm, WA ;
de Tourreil, C ;
Drapeau, JF ;
Fikke, S ;
George, JM ;
Gnandt, E ;
Grisham, T ;
Gutman, I ;
Hartings, R ;
Kremer, R ;
Powell, G ;
Rolfseng, L ;
Rozek, T ;
Ruff, DL ;
Shaffner, D ;
Sklenicka, V ;
Sundararajan, R ;
Yu, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (04) :1503-1515
[14]   Role of air gaps on AC withstand voltage of an ice-covered insulator string [J].
Farzaneh, M. ;
Volat, C. ;
Zhang, J. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (06) :1350-1357
[15]   Effect of insulator diameter on AC flashover voltage of an ice-covered insulator string [J].
Farzaneh, M ;
Zhang, J ;
Volat, C .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (02) :264-271
[16]   Selection of station insulators with respect to ice and snow - Part I: Technical context and environmental exposure [J].
Farzaneh, M ;
Baker, T ;
Bernstorf, A ;
Burnham, JT ;
Carreira, T ;
Cherney, E ;
Chisholm, WA ;
Christman, R ;
Cole, R ;
Cortinas, J ;
de Tourreil, C ;
Drapeau, JF ;
Farzaneh-Dehkordi, J ;
Fikke, S ;
Gorur, R ;
Grisham, T ;
Gutman, I ;
Kuffel, J ;
Phillips, A ;
Powell, G ;
Rolfseng, L ;
Roy, M ;
Rozek, T ;
Ruff, DL ;
Schwalm, A ;
Sklenicka, V ;
Stewart, G ;
Sundararajan, R ;
Szeto, M ;
Tay, R ;
Zhang, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (01) :264-270
[17]  
Farzaneh M., 1992, International Journal of Offshore and Polar Engineering, V2, P228
[18]  
Farzaneh M., 2010, INSULATORS ICING POL
[19]   Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1000 WUHV AC transmission lines [J].
Hu, Jianlin ;
Sun, Caixin ;
Jiang, Xingliang ;
Zhang, Zhijin ;
Shu, Lichun .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) :1347-1356
[20]   Effects of Shed Configuration on AC Flashover Performance of Ice-covered Composite Long-rod Insulators [J].
Hu, Qin ;
Shu, Lichun ;
Jiang, Xingliang ;
Sun, Caixin ;
Zhang, Zhijin ;
Hu, Jianlin .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (01) :200-208