Polyethylene wear in cases using femoral stems of similar geometry, but different metals, porous layer, and modularity

被引:6
作者
Bal, BS [1 ]
Vandelune, D [1 ]
Gurba, DM [1 ]
Jasty, M [1 ]
Harris, WH [1 ]
机构
[1] Massachusetts Gen Hosp, Hip & Implant Unit, Dept Orthopaed Surg, Orthopaed Biomech Lab, Boston, MA 02114 USA
关键词
acetabular component; osteolysis; taper; monoblock; modular head;
D O I
10.1016/S0883-5403(98)90046-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Ln this report, 83 total hip arthroplasties in 75 patients with femoral stems of similar geometry but different metals, porous surfaces, and femoral head-neck; design were compared at a mean follow-up of 66 months (range, 40-104 months). One type of acetabular component and polyethylene were implanted in all hips. The femoral stem was monoblock in 25 hips, and in 58 it had a modular head-neck piece; 70 stems had chrome-cobalt heads, and 13 heads were titanium. Equally satisfactory clinical results were obtained with either type of femoral implant (i.e., modular and monoblock). The calculated average annual linear polyethylene wear was significantly higher for the titanium stems with a plasma-spray porous surface and chrome-cobalt head on a Morse taper than the chrome-cobalt, beaded,monoblock stems (0.22 mm/year vs 0.07 mm/year, P < .0001). The prevalence of periprosthetic osteolysis was higher for these modular sterns (15.7% vs 0%), but this difference was not statistically significant (P = .09). Gross corrosion was present on the taper surfaces of an autopsy-retrieved femoral implant with a modular cobalt-chrome head on a titanium stem. Particles of chromium 3-orthophosphate were present at the taper rim and in the periarticular tissues.
引用
收藏
页码:492 / 499
页数:8
相关论文
共 27 条
[1]  
Barrack, 1994, J Am Acad Orthop Surg, V2, P16
[2]   COMPLICATIONS RELATED TO MODULARITY OF TOTAL HIP COMPONENTS [J].
BARRACK, RL ;
BURKE, DW ;
COOK, SD ;
SKINNER, HB ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05) :688-692
[3]   WEAR INDUCED BY MOTION BETWEEN BONE AND TITANIUM OR COBALT-CHROME ALLOYS [J].
BISCHOFF, UW ;
FREEMAN, MAR ;
SMITH, D ;
TUKE, MA ;
GREGSON, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :713-716
[4]  
BOBYN JD, 1994, CLIN ORTHOP RELAT R, P27
[5]  
BRIEN WW, 1992, CLIN ORTHOP RELAT R, P66
[6]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, P305
[7]   CORROSION BETWEEN THE COMPONENTS OF MODULAR FEMORAL HIP PROSTHESES [J].
COLLIER, JP ;
SURPRENANT, VA ;
JENSEN, RE ;
MAYOR, MB ;
SURPRENANT, HP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (04) :511-517
[8]  
COLLIER JP, 1992, CLIN ORTHOP RELAT R, P129
[9]   CORROSION AND WEAR AT THE MODULAR INTERFACE OF UNCEMENTED FEMORAL STEMS [J].
COOK, SD ;
BARRACK, RL ;
CLEMOW, AJT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :68-72
[10]  
COOK SD, 1994, CLIN ORTHOP RELAT R, P80