Determinations of captopril were made using a nanocomposite electrode modified with CuO nanoparticles (CuO NPs) and multiwall carbon nanotubes (MWCNTs). The voltammetric results indicate that MWCNT can remarkably enhance electrocatalytic activity toward the oxidation of captopril in buffer solution. Characteristics of the electrochemical responses of the modified electrode toward captopril were investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry. The parameters of charge transfer rate constant (k(s)), charge transfer coefficient (alpha), diffusion coefficient (D), electrode surface area (A), and catalytic rate constant (k(h)) were determined, and the results were investigated. The electrocatalytic oxidation current of captopril was found to have a linear relation to concentration over the range 4.6 x 10(-7) M-1 x 10(-5) M (n = 7) determined by the DPASV method. The limit of detection at S/ N ratio of 3 was 2.9 x 10(-7) M (n = 6), and the relative standard deviation was 4.4% at the 4 x 10(-6) M level (n = 6). The prepared modified electrode has the advantages of high sensitivity, low detection limit in comparison with some reported methods, simple preparation and regeneration of the electrode surface by simple polishing that enables acceptable reproducibility. The modified electrode can be applied to determine captopril in tablets and urine samples with satisfactory results.
引用
收藏
页码:1026 / 1035
页数:10
相关论文
共 34 条
  • [31] Electrochemical Determination of Capsaicinoids Content in Soy Sauce and Pot-Roast Meat Products Based on Glassy Carbon Electrode Modified with B-Cyclodextrin/Carboxylated Multi-Wall Carbon Nanotubes
    Gu, Qianhui
    Lu, Chaoqun
    Chen, Kangwen
    Chen, Xingguang
    Ma, Pengfei
    Wang, Zhouping
    Xu, Baocai
    FOODS, 2021, 10 (08)
  • [32] A new electrochemical sensor for the simultaneous determination of guanine and adenine: using a NiAl-layered double hydroxide/graphene oxide-multi wall carbon nanotube modified glassy carbon electrode
    Rezaei, Behzad
    Khosropour, Hossein
    Ensafi, Ali Asghar
    Dinari, Mohammad
    Nabiyan, Afshin
    RSC ADVANCES, 2015, 5 (92) : 75756 - 75765
  • [33] A sensor based on incorporating Ni2+ into ZnO nanoparticles-multi wall carbon nanotubes-poly methyl metacrylat nanocomposite film modified carbon paste electrode for determination of carbohydrates
    Chekin, Fereshteh
    Yazdaninia, Mohammad
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (10) : 967 - 973
  • [34] An Optimized Electrochemical Methodology by Box-Behnken Design for Non-Enzymatic Determination of Uric Acid in Urine Samples Using a Bi2O3 Nanoparticles-Carbon Paste Electrode
    Hernandez-Ramirez, Daniel
    Mendoza-Huizar, Luis Humberto
    Galan-Vidal, Carlos Andres
    Aguilar-Lira, Guadalupe Yoselin
    Rebolledo-Perales, Luz Elena
    Alvarez-Romero, Giaan Arturo
    JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 78 (11) : 1557 - 1565