Airborne 2,5-dimethylfuran as a marker to indicate exposure to indoor tobacco and biomass burning smoke

被引:1
|
作者
Fu, Xianqiang [1 ]
Hern, Diana [2 ]
Attinson, Dionna N. [2 ]
Kponee, Kale Z. [3 ,4 ]
Bartelli, Debra [1 ]
Gretz, Anna M. [1 ]
Smith, Joshua N. [1 ]
Jia, Chunrong [1 ]
机构
[1] Univ Memphis, Sch Publ Hlth, Memphis, TN 38152 USA
[2] Columbia Univ, Mailman Sch Publ Hlth, New York, NY 10032 USA
[3] Harvard TH Chan Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
[4] Harvard TH Chan Sch Publ Hlth, Dept Epidemiol, Boston, MA 02115 USA
关键词
2; 5-Dimethylfuran; Environmental tobacco smoke; Biomass burning; Indoor air; Thermal desorption; VOLATILE ORGANIC-COMPOUNDS; AIR-POLLUTION; TRACE GASES; SUBURBAN NEIGHBORHOODS; SOURCE APPORTIONMENT; HEALTH; EMISSIONS; VOCS; NICOTINE; BENZENE;
D O I
10.1016/j.atmosenv.2021.118509
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Smoke from domestic tobacco smoking and biomass burning is the most harmful indoor air pollutant. This study aimed to evaluate 2,5-dimethylfuran (DMF) as a marker to indicate exposure to environmental tobacco smoke (ETS) and biomass burning smoke (BBS) in households. The evaluation consisted of three indoor air monitoring campaigns in (1) 8 apartments with different smoking scenarios, (2) 76 apartments in a Metropolitan city, and (3) 26 homes in two rural areas. All the air samples were collected in a passive way using thermal desorption (TD) tubes and analyzed by TD-gas chromatography/mass spectrometry (GC/MS). The indoor smoking experiments showed that TD tubes could detect DMF even when the occupant smoked one cigarette every day. In urban homes, DMF detection had a substantial agreement with smoking status, indicated by a Kappa coefficient of 0.67. In rural homes, DMF was detected at high concentrations in homes with biomass burning. Along with DMF, the TD tubes could detect and quantify over 70 other volatile organic compounds (VOCs), allowing exposure and risk assessment for indoor smoke. In conclusion, monitoring DMF with TD tubes offers an easy, low-cost approach to measure domestic ETS and BBS exposures. This method has the potential to measure exposure to outdoor smoke from wildfire and agricultural burning.
引用
收藏
页数:8
相关论文
共 14 条
  • [1] Assessment of Environmental Tobacco Smoke Contamination in Public Premises: Significance of 2,5-Dimethylfuran as an Effective Marker
    Alonso, Monica
    Godayol, Anna
    Antico, Enriqueta
    Sanchez, Juan M.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (21) : 8289 - 8294
  • [2] Using the blood concentration of 2,5-dimethylfuran as a marker for smoking
    Ashley, DL
    Bonin, MA
    Hamar, B
    McGeehin, M
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1996, 68 (03) : 183 - 187
  • [3] Laminar Burning Characteristics of 2-Methylfuran Compared with 2,5-Dimethylfuran and Isooctane
    Ma, Xiao
    Jiang, Changzhao
    Xu, Hongming
    Shuai, Shijin
    Ding, Haichun
    ENERGY & FUELS, 2013, 27 (10) : 6212 - 6221
  • [4] Effects of blending 2,5-dimethylfuran on the laminar burning velocity and ignition delay time of isooctane/air mixture
    Bhattacharya, Atmadeep
    Datta, Amitava
    COMBUSTION THEORY AND MODELLING, 2019, 23 (01) : 105 - 126
  • [5] Catalytic synthesis of renewablep-xylene from biomass-derived 2,5-dimethylfuran: a mini review
    Dutta, Saikat
    Bhat, Navya Subray
    BIOMASS CONVERSION AND BIOREFINERY, 2023, 13 (01) : 541 - 554
  • [6] Biomass-derived 2,5-dimethylfuran as a promising alternative fuel: An application review on the compression and spark ignition engine
    Nguyen, Xuan Phuong
    Hoang, Anh Tuan
    Olcer, Aykut I.
    Engel, Dirk
    Pham, Van Viet
    Nayak, Swarup Kumar
    FUEL PROCESSING TECHNOLOGY, 2021, 214
  • [7] Comparison of breath, blood and urine concentrations in the biomonitoring of environmental exposure to 1,3-butadiene, 2,5-dimethylfuran, and benzene
    Perbellini, L
    Princivalle, A
    Cerpelloni, M
    Pasini, F
    Brugnone, F
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2003, 76 (06) : 461 - 466
  • [8] Comparison of breath, blood and urine concentrations in the biomonitoring of environmental exposure to 1,3-butadiene, 2,5-dimethylfuran, and benzene
    Luigi Perbellini
    Andrea Princivalle
    Marzia Cerpelloni
    Francesco Pasini
    Francesco Brugnone
    International Archives of Occupational and Environmental Health, 2003, 76 : 461 - 466
  • [9] Importance of oxyphilic FeNi alloy in NiFeAl catalysts for selective conversion of biomass-derived 5-hydroxymethylfurfural to 2,5-dimethylfuran
    Shao, Yuewen
    Guo, Mingzhu
    Fan, Mengjiao
    Sun, Kai
    Gao, Guoming
    Li, Chao
    Kontchouo, Felix Merime Bkangmo
    Zhang, Lijun
    Zhang, Shu
    Hu, Xun
    RENEWABLE ENERGY, 2023, 208 : 105 - 118
  • [10] Hydrogenolysis of Biomass-Derived 5-Hydroxymethylfurfural to Produce 2,5-Dimethylfuran Over Ru-ZrO2-MCM-41 Catalyst
    Raut, Amol B.
    Nanda, Binita
    Parida, Kulamani M.
    Bhanage, Bhalchandra M.
    CHEMISTRYSELECT, 2019, 4 (20): : 6080 - 6089