Broadband ferromagnetic resonance linewidth measurement by a microstripline transmission resonator

被引:17
|
作者
Sokolov, Alexander S. [1 ]
Geiler, Michael [1 ]
Harris, Vincent G. [1 ]
机构
[1] Northeastern Univ, Ctr Microwave Magnet Mat & Integrated Circuits, Boston, MA 02115 USA
关键词
SPIN-WAVE INSTABILITY; THIN-FILMS;
D O I
10.1063/1.4948346
中图分类号
O59 [应用物理学];
学科分类号
摘要
The application of microstripline transmission resonators to ferromagnetic resonance linewidth measurements, and the linewidth extraction method based on the resonator resonant frequency dispersion are discussed. A detailed description of the spectrometer and the experimental procedure is presented. The limitations of the method and the origin of various errors that may occur in the measurements are considered. The geometry of the resonator was optimized by numerical methods and the radio-frequency magnetic field structure investigated. A series of magnetic films and bulk samples was measured by the spectrometer under varying circumstances, and results were compared to the ones obtained by conventional methods. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Broadband ferromagnetic resonance linewidth measurement of magnetic tunnel junction multilayers
    Sierra, J. F.
    Aliev, F. G.
    Heindl, R.
    Russek, S. E.
    Rippard, W. H.
    APPLIED PHYSICS LETTERS, 2009, 94 (01)
  • [2] MEASUREMENT OF THE FERROMAGNETIC-RESONANCE LINEWIDTH
    TABARIN, VA
    DEMYANTSEVA, SD
    MEASUREMENT TECHNIQUES, 1978, 21 (10) : 1406 - 1408
  • [3] ON SHAPE OF SAMPLE FOR FERROMAGNETIC RESONANCE LINEWIDTH MEASUREMENT
    NAKAJIMA, T
    ITOH, M
    IEEE TRANSACTIONS ON MAGNETICS, 1966, MAG2 (04) : 780 - +
  • [4] Ferromagnetic resonance linewidth in metallic thin films: Comparison of measurement methods
    Kalarickal, Sangita S.
    Krivosik, Pavol
    Wu, Mingzhong
    Patton, Carl E.
    Schneider, Michael L.
    Kabos, Pavel
    Silva, T.J.
    Nibarger, John P.
    Journal of Applied Physics, 2006, 99 (09):
  • [5] Ferromagnetic resonance linewidth in metallic thin films: Comparison of measurement methods
    Kalarickal, Sangita S.
    Krivosik, Pavol
    Wu, Mingzhong
    Patton, Carl E.
    Schneider, Michael L.
    Kabos, Pavel
    Silva, T. J.
    Nibarger, John P.
    JOURNAL OF APPLIED PHYSICS, 2006, 99 (09)
  • [6] TEMPERATURE DEPENDENCE OF FERROMAGNETIC RESONANCE LINEWIDTH
    LEICHNER, PK
    RICHARDS, PM
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1969, 14 (02): : 194 - &
  • [7] ANISOTROPIC FERROMAGNETIC RESONANCE LINEWIDTH IN FERRITES
    CALLEN, HB
    PITTELLI, E
    PHYSICAL REVIEW, 1960, 119 (05): : 1523 - 1531
  • [8] FERROMAGNETIC RESONANCE LINEWIDTH IN FERROELECTRIC FERROMAGNETS
    CHUPIS, IE
    PLYUSHKO, NY
    SOVIET PHYSICS SOLID STATE,USSR, 1972, 13 (08): : 1890 - &
  • [10] Broadband ferromagnetic resonance spectrometer
    Denysenkov, VP
    Grishin, AM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (07): : 3400 - 3405