ANALYSING THE EFFECT OF A CRANIUM THICKNESS ON A BRAGG PEAK RANGE IN THE PROTON THERAPY: A TRIM AND GEANT4 BASED STUDY

被引:4
作者
Ekinci, F. [1 ]
Bostanci, E. [2 ]
Guzel, M. S. [2 ]
Dagil, O. [1 ]
机构
[1] Gazi Univ, Ankara, Turkey
[2] Ankara Univ, Ankara, Turkey
来源
ST PETERSBURG POLYTECHNIC UNIVERSITY JOURNAL-PHYSICS AND MATHEMATICS | 2022年 / 15卷 / 02期
关键词
Monte Carlo; GEANT4; TRIM; radiation therapy; proton therapy; LET; ARTERIOVENOUS-MALFORMATIONS; ENERGY DEPOSITION; HEAVY-ION; CODE; EMBOLIZATION; SIMULATIONS; SLAB;
D O I
10.18721/JPM.15207
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Cancer treatment with proton therapy, starting in 1946, continues with the treatment of 200,000 patients worldwide as of 2020. The energy release of protons in tissue and tissue equivalent (water) material is shown by Bragg curves. The main reason why proton beams are preferred in radiotherapy is that the proton beams continue on their way by giving maximum energy to the tissue to be treated and giving the least damage to the healthy tissue. In this study, with the help of Monte Carlo-based GEANT4 and TRIM simulation programs, Bragg peak positions in the 60 - 130 MeV energy range are given for water and brain by using the relativistic Bethe - Bloch equation. The difference between GEANT4 and TRIM was 7.4 % on average in the water phantom, while the difference was 7.6 % in the brain phantom. Bragg peak position was calculated for water and brain phantoms at 0.6, 0.8 and 1.0 cm thicknesses, which is suitable for the average thickness of the cortical bone in the skull. An average of 8.1 and 7.8 % deviations were detected between the two simulation systems in the cortical bony, water and brain phantoms with three different thicknesses. The values found were compared with the clinical studies available in the literature.
引用
收藏
页码:64 / 78
页数:15
相关论文
共 47 条
[1]  
Almhagen E., 2015, THESIS, P48
[2]  
[Anonymous], Geant4
[3]   Investigation of single carbon ion fragmentation in water and PMMA for hadron therapy [J].
Arico, G. ;
Gehrke, T. ;
Gallas, R. ;
Mairani, A. ;
Jaekel, O. ;
Martisikova, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (05)
[4]   An overview of recent developments in FLUKA PET TOOLS [J].
Augusto, R. S. ;
Bauer, J. ;
Bouhali, O. ;
Cuccagna, C. ;
Gianoli, C. ;
Kozlowska, W. S. ;
Ortega, P. G. ;
Tessonnier, T. ;
Toufique, Y. ;
Vlachoudis, V. ;
Parodi, K. ;
Ferrari, A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 54 :189-199
[5]   The origin of neutron biological effectiveness as a function of energy [J].
Baiocco, G. ;
Barbieri, S. ;
Babini, G. ;
Morini, J. ;
Alloni, D. ;
Friedland, W. ;
Kundrat, P. ;
Schmitt, E. ;
Puchalska, M. ;
Sihver, L. ;
Ottolenghi, A. .
SCIENTIFIC REPORTS, 2016, 6
[6]  
Battistoni G, 2007, AIP CONF PROC, V896, P31, DOI 10.1063/1.2720455
[7]   INFLUENCE OF THE PHANTOM SHAPE (SLAB, CYLINDER OR ALDERSON) ON THE PERFORMANCE OF AN Hp(3) EYE DOSEMETER [J].
Behrens, R. ;
Hupe, O. .
RADIATION PROTECTION DOSIMETRY, 2016, 168 (04) :441-449
[8]   The FLUKA Code: Developments and Challenges for High Energy and Medical Applications [J].
Boehlen, T. T. ;
Cerutti, F. ;
Chin, M. P. W. ;
Fosso, A. ;
Ferrari, A. ;
Ortega, P. G. ;
Mairani, A. ;
Sala, P. R. ;
Smirnov, G. ;
Vlachoudisl, V. .
NUCLEAR DATA SHEETS, 2014, 120 :211-214
[9]   Monte Carlo investigation of the characteristics of radioactive beams for heavy ion therapy [J].
Chacon, Andrew ;
Safavi-Naeini, Mitra ;
Bolst, David ;
Guatelli, Susanna ;
Franklin, Daniel R. ;
Iwao, Yuma ;
Akamatsu, Go ;
Tashima, Hideaki ;
Yoshida, Eiji ;
Nishikido, Fumihiko ;
Kitagawa, Atsushi ;
Mohammadi, Akram ;
Gregoire, Marie-Claude ;
Yamaya, Taiga ;
Rosenfeld, Anatoly B. .
SCIENTIFIC REPORTS, 2019, 9 (1)
[10]   Response of gadolinium doped liquid scintillator to charged particles: measurement based on intrinsic U/Th contamination [J].
Du, Q. ;
Lin, S. T. ;
He, H. T. ;
Liu, S. K. ;
Tang, C. J. ;
Wang, L. ;
Wong, H. T. ;
Xing, H. Y. ;
Yue, Q. ;
Zhu, J. J. .
JOURNAL OF INSTRUMENTATION, 2018, 13