Reliability of methods to measure energy expenditure during and after resistance exercise

被引:7
作者
Lyristakis, Philip [1 ]
Ball, Nick [1 ]
McKune, Andrew J. [1 ,2 ]
机构
[1] Univ Canberra, Res Inst Sport & Exercise UCRISE, Canberra, ACT, Australia
[2] Univ KwaZulu Natal, Sch Hlth Sci, Discipline Biokinet Exercise & Leisure Sci, Kwa Zulu, South Africa
关键词
anaerobic; energy; expenditure; resistance; exercise; weight; training; metabolic; cost; INTENSITY; LACTATE; COSTS;
D O I
10.1139/apnm-2019-0076
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
The primary purpose of this study was to assess the reliability of 3 methods estimating energy expenditure (EE) during and in response to resistance exercise. Ten males (aged 29.4 +/- 10.2 years) with >= 2 months resistance training (RT) experience performed 3 training sessions incorporating the bench press and back-squat; sessions were separated by 48 to 72 h. Total energy expenditure (TEE) was estimated using a Suunto T6D Heart Rate Monitor and 2 methods (named "Scott" and "Magosso") that used oxygen uptake and blood lactate measurements to determine aerobic and anaerobic energy expenditure (AnEE). For TEE, relative reliability for both the Scott and Magosso methods remained "nearly perfect" across all testing days for the bench press and back-squat; with interclass correlations (ICC) > 0.93 and percentage of the typical error measurement (TEM%) below 5.8%. The heart rate method showed moderate variability between testing days for both exercises; ICCs ranged between 0.66-0.92 with TEM% between 18%-37% during the bench press and 11%-17% during the back-squat. The estimation of AnEE showed that the Scott and Magosso methods had "strong" to "very strong" relative reliability for both exercises; however, a low absolute reliability was observed. Mean EE was significantly higher in the Scott and Magosso methods during the bench press >912 kJ and back-squat >1170 kJ, with the heart rate method estimating 358 kJ and 416 kJ. The Scott and Magosso methods showed a high degree of reliability between testing days when measuring EE. Heart rate methods may significantly underestimate EE during and in response to RT.
引用
收藏
页码:1276 / 1282
页数:7
相关论文
共 30 条
[1]  
[Anonymous], 2010, ACSMS GUIDELINES EXE
[2]  
[Anonymous], J INT SOC SPORT NUTR
[3]  
[Anonymous], EN EXP EST METH BAS
[4]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[5]   Cardiovascular Fitness and Energy Expenditure Response during a Combined Aerobic and Circuit Weight Training Protocol [J].
Benito, Pedro J. ;
Alvarez-Sanchez, Maria ;
Diaz, Victor ;
Morencos, Esther ;
Peinado, Ana B. ;
Cupeiro, Rocio ;
Maffulli, Nicola .
PLOS ONE, 2016, 11 (11)
[6]  
Earle R., 2004, NSCAS ESSENTIALS PER
[7]  
Earle R.W., 2008, Essentials of strength training and conditioning, V3rd, DOI DOI 10.1016/S0031-9406(05)66120-2
[8]  
Ehrman J., 2009, CLIN EXERCISE PHYSL, V2nd
[9]   METABOLIC COST OF ROPE TRAINING [J].
Fountaine, Charles J. ;
Schmidt, Brad J. .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2015, 29 (04) :889-893
[10]  
Hopkins W.G., 2000, a new view of statistics. Internet society for sport science