Morphology of contact lens-induced conjunctival epithelial flaps: A pilot study

被引:5
作者
Bergmanson, Jan P. G. [1 ]
Tukler, Johanna [1 ]
Leach, Norman E. [1 ]
Alabdelmoneam, Mussaed [2 ]
Miller, William L. [1 ]
机构
[1] Univ Houston, Coll Optometry, Texas Eye Res & Technol Ctr, Houston, TX 77004 USA
[2] Shaqra Univ, Shaqra, Saudi Arabia
关键词
Conjunctival epithelial flaps; Silicone hydrogel contact lens; Impression cytology; IMPRESSION CYTOLOGY; OCULAR SURFACE; EYE DISEASE; WEARERS; CORNEAL;
D O I
10.1016/j.clae.2012.03.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Conjunctival epithelial flap (CEF) is a conjunctival condition most commonly seen in silicone hydrogel contact lens wearers. This study utilized impression cytology to investigate the cellular composition and health of CEFs. Methods: Nine (9) subjects were enrolled - 3 non-lens wearers, 3 contact lens wearers without CEF, and 3 contact lens wearers with CEFs wearing 8.4/13.8 lotrafilcon A lenses. Impression cytology samples were collected from the flap or similar locations, if CEF was absent, using rectangular 5 mm x 2 mm Millipore HAWP02500 membrane filters. The filters were gently pressed onto the conjunctiva, subsequently fixed in 95% alcohol, stained with hematoxylin-eosin and evaluated under an Olympus IX70 microscope. Measurements of the longest cell and nucleus dimensions were measured on 40 cells from each filter by utilizing NIH Image 1.63. Results: CEF consisted of multilayers of epithelial and goblet cells and were devoid of inflammatory cells, basement membrane material and stromal tissue. The cytoplasmic and nuclear dimensions were similar within the groups and the cytoplasm-to-nucleus ratio was not different between the flap group and the non-lens wearing group. Conclusion: The CEF appeared to be formed by healthy epithelial and goblet cells that have been dislocated from their normal location along the conjunctival surface by the lens edge. No inflammatory cells were present in this contact lens induced condition, which is reported to be associated most commonly with the silicone hydrogel material. (C) 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:185 / 188
页数:4
相关论文
共 31 条
[1]  
Adar S, 1997, CORNEA, V16, P289
[2]  
Bergmanson JPG, 2011, CLIN OCULAR ANATOMY, P35
[3]   Corneal and Conjunctival Epithelial Staining in Hydrogel Contact Lens Wearers [J].
Brautaset, Rune L. ;
Nilsson, Maria ;
Leach, Norman ;
Miller, William L. ;
Gire, Anisa ;
Quintero, Sam ;
Bergmanson, Jan P. G. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (06) :312-316
[4]  
Brennan Noel A, 2007, Cont Lens Anterior Eye, V30, P108
[5]  
Cakmak Sevin Soker, 2003, Eye Contact Lens, V29, P230
[6]   Impression cytology of the ocular surface:: a review [J].
Calonge, M ;
Diebold, Y ;
Sáez, V ;
de Salamanca, AE ;
García-Vázquez, C ;
Corrales, RM ;
Herreras, JM .
EXPERIMENTAL EYE RESEARCH, 2004, 78 (03) :457-472
[7]  
Connor C G, 1994, J Am Optom Assoc, V65, P792
[8]  
DEROJAS MV, 1993, CYTOPATHOLOGY, V4, P347
[9]   Diagnostic impression cytology: a simple technique for the diagnosis of external eye disease [J].
Divani, SN ;
Margari, C ;
Zikos, GA ;
Zikos, A ;
Papavassiliou, GB .
CYTOPATHOLOGY, 1997, 8 (06) :373-380
[10]  
Doughty Michael J, 2008, Cont Lens Anterior Eye, V31, P131, DOI 10.1016/j.clae.2007.12.002