Uncertainty Evaluation of Primary Reference Photovoltaic Cell Calibration under Outdoor Condition in Tibet

被引:0
作者
Liu, Haitao [1 ]
Sang, Shiyu [1 ]
Zhou, Guomin [2 ]
Zhai, Yonghui [1 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Key Lab Solar Thermal Energy & Photovolta Syst, Beijing 100190, Peoples R China
[2] Tibet New Energy Res & Demonstrat Ctr, Lhasa 850000, Peoples R China
来源
2017 IEEE 44TH PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC) | 2017年
关键词
uncertainty; reference cell; primary calibration; spectral mismatch factor;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A primary reference cell calibration testbed using direct normal irradiance calibration method is developed to establish calibration traceability chain of PV scale by Institute of Electrical Engineering (IEECAS) and New Energy Research and Demonstration Centre (NERDC) of Tibet. The testbed is designed to carry out PV reference cell primary calibration under direct irradiance condition, which meets the requirement of IEC 60904-4. The calibration value and uncertainty analysis of direct normal irradiance, spectral mismatch correction, and short-circuit current measurement are discussed and evaluated for photovoltaic metrology calibration reference. The calibration method is based on absolute cavity radiometer which is calibrated against world radiation scale. The calibration result shows expanded uncertainty of 0.91% and desired results reproducibility for establishing on-site photovoltaic metrology traceability chain in China.
引用
收藏
页码:476 / 479
页数:4
相关论文
共 8 条
  • [1] Evaluation of the Uncertainty of Surface Temperature Measurements in Photovoltaic Modules in Outdoor Operation
    Garcia-Lopez, Carmen
    Alvarez-Tey, German
    SENSORS, 2022, 22 (15)
  • [2] Complex-Valued Frequency Response of Hydrophones: Primary Calibration and Uncertainty Evaluation
    Weber, Martin
    Wilkens, Volker
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [3] Pitch calibration of standard nanoscale for uncertainty reduction of certified reference materials for SEM image sharpness evaluation and magnification calibration
    Misumi, Ichiko
    Kumagai, Kazuhiro
    Kizu, Ryosuke
    SURFACE TOPOGRAPHY-METROLOGY AND PROPERTIES, 2022, 10 (04)
  • [4] Closed-Loop Uncertainty: The Evaluation and Calibration of Uncertainty for Human-Machine Teams under Data Drift
    Bishof, Zachary
    Scheuerman, Jaelle
    Michael, Chris J.
    ENTROPY, 2023, 25 (10)
  • [5] Evaluation of the stability of ethanol in water certified reference material: measurement uncertainty under transport and storage conditions
    de Souza, Vanderlea
    Rodrigues, Janaina Marques
    Cunha Bandeira, Raquel Duarte da C.
    das Neves Valente, Laura A.
    Barreto Sousa, Marcus Vinicius
    da Silva, Viviane Fernandes
    Lemos da Silva, Rafael Agostinho
    ACCREDITATION AND QUALITY ASSURANCE, 2008, 13 (12) : 717 - 721
  • [6] Evaluation of the stability of ethanol in water certified reference material: measurement uncertainty under transport and storage conditions
    Vanderléa de Souza
    Janaína Marques Rodrigues
    Raquel Duarte da C. Cunha Bandeira
    Laura A. das Neves Valente
    Marcus Vinícius Barreto Sousa
    Viviane Fernandes da Silva
    Rafael Agostinho Lemos da Silva
    Accreditation and Quality Assurance, 2008, 13 : 717 - 721
  • [7] Operation optimization and performance evaluation of photovoltaic-wind-hydrogen-based integrated energy system under carbon trading mechanism and uncertainty for urban communities
    Zhen, Jiliang
    Liu, Xiaoran
    Wu, Chuanbao
    Ji, Ling
    Huang, Guohe
    JOURNAL OF CLEANER PRODUCTION, 2024, 476
  • [8] Dynamic performance evaluation of automated QFT robust controller for grid-tied fuel cell under uncertainty conditions
    Gudimindla, Hemachandra
    Sharma, Manjunatha K.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 42 (42)