Ultrathin section preparation of phyllosilicates by Focused Ion Beam milling for quantitative analysis by TEM-EDX

被引:19
作者
Bourdelle, Franck [1 ,4 ]
Parra, Teddy [2 ]
Beyssac, Olivier [3 ]
Chopin, Christian [4 ]
Moreau, Florent [5 ]
机构
[1] Univ Cergy Pontoise, Dept Geosci & Environm, F-95031 Neuville Sur Oise, Cergy Pontoise, France
[2] IFP Energies Nouvelles, F-92852 Rueil Malmaison, France
[3] UPMC CNRS, IMPMC, F-75252 Paris 05, France
[4] Ecole Normale Super CNRS, Lab Geol, F-75231 Paris 05, France
[5] IFP Energies Nouvelles, F-69360 Solaize, France
关键词
Focused Ion Beam (FIB); Sample preparation; Phyllosilicate; Analytical TEM; Analytical protocol; PHASE-EQUILIBRIUM EXPERIMENTS; NATURAL PELITIC ASSEMBLAGES; X-RAY-MICROANALYSIS; CHEMICAL-COMPOSITION; THERMODYNAMIC MODEL; LOCAL EQUILIBRIA; THIN SPECIMENS; ZETA-FACTOR; CHLORITE; GEOTHERMOMETER;
D O I
10.1016/j.clay.2012.02.010
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The composition of the phyllosilicates mica and chlorite is commonly used in thermobarometry to decipher the geological history of rocks. The thermobarometers that have been proposed during the last thirty years rely on the use of electron microprobe (EMP) analyses, with a spatial resolution limited to the micrometer scale. Such a resolution may not be appropriate for the size of clay particles or chemical zoning in very low grade rocks. In this respect, the transmission electron microscope coupled to an X-ray energy dispersive spectrometer (TEM-EDX) provides the proper spatial resolution in analysis. It is combined here with Focused Ion Beam (FIB) milling which makes possible in situ preparation of TEM samples with high spatial control and preservation of mineral microtextures. We test the suitability of FIB-milling for TEM-analysis of clay minerals, considering the effects of intrinsic preparation artifacts like amorphization, beam damage, Ga ions implantation and material redeposition. In addition, we evaluate a TEM-EDX analytical protocol adapted to clay minerals and yielding the FIB-section thickness at each analysis point in a non destructive way. The TEM k factors were calibrated on clay powders. A comparison between TEM-EDX and EMP analyses obtained on the same phyllosilicates in FIB and polished thin sections, respectively, shows excellent agreement, thereby validating the analytical protocol and the use of FIB-sections for the study of clay minerals. The combination of these preparation and analytical procedures opens new avenues for the petrologic study of clay-mineral-bearing assemblages at an unprecedented spatial resolution. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 130
页数:10
相关论文
共 34 条
[21]   A thermodynamic model for Fe-Mg dioctahedral K white micas using data from phase-equilibrium experiments and natural pelitic assemblages [J].
Parra, T ;
Vidal, O ;
Agard, P .
CONTRIBUTIONS TO MINERALOGY AND PETROLOGY, 2002, 143 (06) :706-732
[22]   Relation between the intensity of deformation and retrogression in blueschist metapelites of Tinos Island (Greece) evidenced by chlorite-mica local equilibria [J].
Parra, T ;
Vidal, O ;
Jolivet, L .
LITHOS, 2002, 63 (1-2) :41-66
[23]  
Salvat F., 2006, PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport
[24]   QUANTITATIVE TRANSMISSION-X-RAY MICROANALYSIS OF IONIC COMPOUNDS [J].
VANCAPPELLEN, E ;
DOUKHAN, JC .
ULTRAMICROSCOPY, 1994, 53 (04) :343-349
[25]   P-T-deformation-Fe3+/Fe2+ mapping at the thin section scale and comparison with XANES mapping:: application to a garnet-bearing metapelite from the Sambagawa metamorphic belt (Japan) [J].
Vidal, O. ;
De Andrade, V. ;
Lewin, E. ;
Munoz, M. ;
Parra, T. ;
Pascarelli, S. .
JOURNAL OF METAMORPHIC GEOLOGY, 2006, 24 (07) :669-683
[26]   Exhumation paths of high-pressure metapelites obtained from local equilibria for chlorite-phengite assemblages [J].
Vidal, O ;
Parra, T .
GEOLOGICAL JOURNAL, 2000, 35 (3-4) :139-161
[27]   A thermodynamic model for Fe-Mg aluminous chlorite using data from phase equilibrium experiments and natural pelitic assemblages in the 100° to 600°C, 1 to 25 kb range [J].
Vidal, O ;
Parra, T ;
Trotet, F .
AMERICAN JOURNAL OF SCIENCE, 2001, 301 (06) :557-592
[28]   The quantitative analysis of thin specimens:: a review of progress from the Cliff-Lorimer to the new ζ-factor methods [J].
Watanabe, M ;
Williams, DB .
JOURNAL OF MICROSCOPY, 2006, 221 (89-109) :89-109
[29]   Absorption correction and thickness determination using the zeta factor in quantitative X-ray microanalysis [J].
Watanabe, M ;
Horita, Z ;
Nemoto, M .
ULTRAMICROSCOPY, 1996, 65 (3-4) :187-198
[30]  
Watanabe M, 1999, MICROSC MICROANAL, V5, P88