Patient-Prosthesis Mismatch in Contemporary Small-Size Mechanical Prostheses Does Not Impact Survival at 10 Years

被引:1
作者
Feier, Horea [1 ,2 ]
Mocan, Mihaela [3 ]
Grigorescu, Andrei [1 ,2 ]
Falnita, Lucian [2 ]
Gaspar, Marian [1 ,2 ]
Luca, Constantin-Tudor [1 ,2 ]
机构
[1] Univ Med Pharm Victor Babes Timisoara, Dept Cardiol, Timisoara 300041, Romania
[2] Res Ctr Inst Cardiovasc Dis, Timisoara 300310, Romania
[3] Univ Med & Pharm Iuliu Hatieganu Cluj Napoca, Dept Cardiol, Cluj Napoca 400012, Romania
关键词
aortic valve; mechanical valve; patient-prosthesis mismatch; propensity matching; AORTIC-VALVE-REPLACEMENT; LONG-TERM SURVIVAL; IMPLANTATION; MORTALITY; STENOSIS; OUTCOMES;
D O I
10.3390/jcdd9020048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The effect of PPM in mechanical prostheses on long-term survival is not well-established. Methods: Patients who received a 21 mm or smaller aortic valve between 2000 and 2011 were retrospectively analyzed (n = 416). Propensity matching was used in order to account for baseline differences in patient subgroups (PPM vs. no PPM; severe PPM vs. no severe PPM). Results: Five- and ten-year survival was 78 +/- 3.52% and 64.51 +/- 4.51% in patients with PPM, versus 83.3 +/- 3.12% and 69.37 +/- 4.36% in patients without (p = 0.28) when analyzed at 10.39 +/- 5.25 years after the primary procedure. Independent risk factors for impaired survival, after matching, were age, serum creatinine, and severe pulmonary hypertension. Five- and ten-year survival in patients with severe PPM was 73.34 +/- 6.01% and 61.76 +/- 8.17%, respectively, versus 74.72 +/- 5.68% and 67.50 +/- 7.09% in those without (p = 0.49), at 8.82 +/- 5.17 years after SAVR. Age was the only independent variable that influenced long-term survival when severe PPM was added to the model. Conclusions: PPM or severe PPM does not impact long-term survival up to 10 years in mechanical valve recipients when matching for preoperative variables.
引用
收藏
页数:11
相关论文
共 17 条
  • [1] Does patient-prosthesis mismatch after aortic valve replacement affect survival and quality of life in elderly patients?
    Sportelli, Elena
    Regesta, Tommaso
    Salsano, Antonio
    Ghione, Paola
    Brega, Carlotta
    Bezante, Gian Paolo
    Passerone, Giancarlo
    Santini, Francesco
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2016, 17 (02) : 137 - 143
  • [2] The effect of patient-prosthesis mismatch on survival after aortic and mitral valve replacement: a 10 year, single institution experience
    Das De, Sudeep
    Nanjappa, Ashok
    Morcos, Karim
    Aftab, Sadia
    Butler, John
    Pathi, Vivek
    Curry, Philip
    Nair, Sukumaran
    JOURNAL OF CARDIOTHORACIC SURGERY, 2019, 14 (01)
  • [3] Aortic Valve Replacement With 17-mm Mechanical Prostheses: Is Patient-Prosthesis Mismatch a Relevant Phenomenon?
    Garatti, Andrea
    Mori, Francesca
    Innocente, Francesco
    Canziani, Alberto
    Gagliardotto, Piervincenzo
    Mossuto, Eugenio
    Santoro, Tiberio
    Montericcio, Vincenzo
    Frigiola, Alessandro
    Menicanti, Lorenzo
    ANNALS OF THORACIC SURGERY, 2011, 91 (01) : 71 - 78
  • [4] Patient-prosthesis mismatch after transapical aortic valve implantation: Incidence and impact on survival
    Kukucka, Marian
    Pasic, Miralem
    Dreysse, Stephan
    Mladenow, Alexander
    Habazettl, Helmut
    Hetzer, Roland
    Unbehaun, Axel
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (02) : 391 - 397
  • [5] Patient-prosthesis mismatch does not affect survival following aortic valve replacement
    Howell, Neil J.
    Keogh, Bruce E.
    Barnet, Vivien
    Bonser, Robert S.
    Graham, Timothy R.
    Rooney, Stephen J.
    Wilson, Ian C.
    Pagano, Domenico
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (01) : 10 - 14
  • [6] Patient-Prosthesis Mismatch in Elderly Patients Undergoing Aortic Valve Replacement: Impact on Quality of Life and Survival
    Urso, Stefano
    Sadaba, Rafael
    Vives, Manuel
    Trujillo, John
    Beltrame, Sergio
    Soriano, Beatriz
    Piqueras, Lucia
    Aldamiz-Echevarria, Gonzalo
    JOURNAL OF HEART VALVE DISEASE, 2009, 18 (03) : 248 - 255
  • [7] Clinical Impact of Patient-Prosthesis Mismatch After Aortic Valve Replacement With a Mechanical or Biological Prosthesis
    Matkovic, Milos
    Aleksic, Nemanja
    Bilbija, Ilija
    Antic, Ana
    Lazovic, Jelena Milin
    Cubrilo, Marko
    Milojevic, Aleksandar
    Zivkovic, Igor
    Putnik, Svetozar
    TEXAS HEART INSTITUTE JOURNAL, 2023, 50 (05)
  • [8] Does patient-prosthesis mismatch have a negative impact on outcomes following mitral valve replacement?
    Aboul-Hassan, Sleiman Sebastian
    Stankowski, Tomasz
    Marczak, Jakub
    Cichon, Romuald
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2018, 26 (06) : 1027 - 1034
  • [9] Patient-Prosthesis Mismatch in Patients With Aortic Stenosis Undergoing Isolated Aortic Valve Replacement Does Not Affect Survival
    Howell, Neil J.
    Keogh, Bruce E.
    Ray, Daniel
    Bonser, Robert S.
    Graham, Tim R.
    Mascaro, Jorge
    Rooney, Stephen J.
    Wilson, Ian C.
    Pagano, Domenico
    ANNALS OF THORACIC SURGERY, 2010, 89 (01) : 60 - 64
  • [10] Impact of Patient-Prosthesis Mismatch following Aortic Valve Replacement on Long-Term Survival and Quality of Life
    Hoffmann, Grischa
    Abraham-Westphal, Selam
    Attmann, Tim
    Frank, Derk
    Lutter, Georg
    Cremer, Jochen
    Petzina, Rainer
    THORACIC AND CARDIOVASCULAR SURGEON, 2020, 68 (02) : 124 - 130