Dependence of Water-equivalent Diameter and Size-specific Dose Estimates on CT Tube Potential

被引:8
作者
McCollough, Cynthia H. [1 ]
McCollough, Shannon L. [1 ]
Schneider, Justine J. [1 ]
Moen, Taylor R. [1 ]
Weaver, Jayse M. [1 ]
Vrieze, Thomas J. [1 ]
Yu, Lifeng [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
ATTENUATION-BASED ESTIMATION; IMAGE QUALITY; PATIENT SIZE; PURPOSE;
D O I
10.1148/radiol.210860
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The size-specific dose estimate (SSDE) is a patient-focused CT dose metric. However, published size-dependent conversion factors (f(size)) used to calculate SSDE were determined primarily by using phantoms; only eight to 15 patient data sets were used, all at 120 kV. Purpose: To determine the effect of different tube potentials on the water-equivalent diameter (WED) and SSDE for patient CT scans of the head, chest, and abdomen. Materials and Methods: This retrospective study used 250 noncontrast CT scans acquired between March 2013 and June 2017. Bony structures were segmented, and their CT numbers were modified to reflect bone attenuation at 70, 90, 110, 130, and 150 kV. Soft-tissue CT numbers were unchanged because of negligible energy dependence. f(size) was measured in anthropomorphic phantoms for each tube potential and fit to an exponential function. WED and SSDE were determined for each patient at all tube potentials, regression analysis was performed relative to the WED and SSDE at 120 kV, and mean differences relative to 120 kV were calculated. Results: In 250 patients (median age, 21.5 years; interquartile range, 44 years; 130 women), WED for all tube potentials was linearly related to the WED at 120 kV in all body regions (R-2 = 0.995-1.000). The effect of tube potential on WED was negligible for torso examinations (Cohen d < 0.05). In the head, a medium effect size was observed at 70 kV; however, the mean absolute difference in WED was small (-0.49 cm +/- 0.08 [standard deviation]; P< .001). For commonly used combinations of tube potential and patient size, the mean differences in SSDE at alternative tube potentials relative to SSDE at 120 kV were less than 5%. Conclusion: At noncontrast CT, published size-dependent conversion factors accurately determined size-specific dose estimates on 250 patient scans at five tube potentials other than 120 kV. (C) RSNA, 2022
引用
收藏
页数:8
相关论文
共 36 条
[31]   HeadCTDosi: A python']python-based automated calculation of head water equivalent diameter and size specific dose estimate based on AAPM 220 report [J].
Sekkat, H. ;
Khallouqi, A. ;
El Rhazouani, O. ;
Halimi, A. ;
Madkouri, Y. .
RADIATION PHYSICS AND CHEMISTRY, 2025, 227
[32]   Radiation doses and size-specific dose estimate from CT brain examinations according to head sizes in a tertiary hospital in Malaysia [J].
Kayun, Zunaide ;
Karim, Muhammad Khalis Abdul ;
Harun, Hanif Haspi ;
Shaari, Abdul Halim ;
Mahmud, Rozi ;
Hamid, Hamzaini Abdul ;
Sabarudin, Akmal ;
Chew, Ming Tsuey .
RADIATION PHYSICS AND CHEMISTRY, 2021, 189
[33]   Dosimetric comparison of three different cardiac CT angiography techniques in a dual-source scanner using size-specific dose estimation (SSDE) [J].
Robatjazi, Mostafa ;
Alizadeh, Navid Sarmast ;
Molazadeh, Mikaeil ;
Shokoohy, Fatemeh ;
Javadinia, Seyed Alireza ;
Dareyni, Amir ;
Mosavi, Maryam .
RADIATION PHYSICS AND CHEMISTRY, 2025, 232
[34]   A new method for CT dose estimation by determining patient water equivalent diameter from localizer radiographs: Geometric transformation and calibration methods using readily available phantoms [J].
Zhang, Da ;
Mihai, Georgeta ;
Barbaras, Larry G. ;
Brook, Olga R. ;
Palmer, Matthew R. .
MEDICAL PHYSICS, 2018, 45 (07) :3371-3378
[35]   Dose reduction potential in diagnostic single energy CT through patient-specific prefilters and a wider range of tube voltages [J].
Steidel, Jorg ;
Maier, Joscha ;
Sawall, Stefan ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2022, 49 (01) :93-106
[36]   Evaluation of automated attenuation-based tube potential selection in combination with organ-specific dose reduction for contrast-enhanced chest CT examinations [J].
Schimmoeller, L. ;
Lanzman, R. S. ;
Dietrich, S. ;
Boos, J. ;
Heusch, P. ;
Miese, F. ;
Antoch, G. ;
Kroepil, P. .
CLINICAL RADIOLOGY, 2014, 69 (07) :721-726