Cochlear implants in children: safety as well as speech and language

被引:10
作者
Clark, G [1 ]
机构
[1] Univ Melbourne, Bion Ear Inst, Melbourne, Vic 3002, Australia
关键词
cochlear implantation; safety; neural plasticity; rehabilitation;
D O I
10.1016/j.ijporl.2003.08.006
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The development of cochlear implants for children at the University of Melbourne and the Bionic Ear Institute, has consisted of a routine of biological and engineering safety followed by evaluation of speech processing strategies on adults before they are undertaken on children. The initial safety studies were to ensure that insertion was atraumatic, the electrical stimulus parameters did not lead to loss of ganglion cells and that the electrode could be inserted without the risk of middle ear infection leading to meningitis. The initial second formant extraction scheme was shown to produce significant open-set speech understanding in adults and was approved by the US Food and Drug Administration (FDA) in 1985. Following this, an international study was undertaken for the FDA on children using a strategy that also included the first formant, and was approved in 1990. Additional advances in speech processing have been evaluated on adults. However, before using one with high rates of stimulation, it was tested for safety on experimental animals. Further advances have been anticipated in particular through the development of a peri-modiolar array, the Nucleus Contour. Prior to its use on adults, it was tested in the human temporal bone and found to lead to minimal trauma. It was evaluated in adults and found to lead to better current localization and lower thresholds. A study was undertaken in children using a spectra[ maxima scheme at high rates (advanced combination encoder (ACE)) and the Contour array as it had given best results in adults. It was approved as safe and effective for use in children in 2000. Studies were also undertaken to took at plasticity and visual dominance particularly through cognitive studies and the use of the McGurk effect. This demonstrated that deaf children with implants rely heavily on visual information and there is a great need to have unambiguous auditory stimuli to get best results. (C) 2003 British Association for Paediatric Otorhinolaryngology. Published by Elsevier Ireland Ltd. All. rights reserved.
引用
收藏
页码:S7 / S20
页数:14
相关论文
共 43 条
[1]  
Arndt P, 1999, WITHIN SUBJECT COMP
[2]   STAPEDECTOMY AND FATAL MENINGITIS - HUMAN TEMPORAL BONE STUDY [J].
BENITEZ, JT .
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1977, 39 (02) :94-100
[3]  
BLAMEY PJ, 1998, P ICSLP 98 AUSTR SPE, P2615
[4]   Electrode discrimination by early-deafened subjects using the Cochlear Limited multiple-electrode cochlear implant [J].
Busby, PA ;
Clark, GM .
EAR AND HEARING, 2000, 21 (04) :291-304
[5]   Pitch estimation by early-deafened subjects using a multiple-electrode cochlear implant [J].
Busby, PA ;
Clark, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 107 (01) :547-558
[6]  
Clark G., 2003, AIP SER MOD AC SIG
[7]  
CLARK G, 1987, U MELBOURNE NUCL MUL
[8]  
CLARK GM, 1984, ACTA OTO-LARYNGOL, P5
[9]   A MULTIPLE-CHANNEL COCHLEAR IMPLANT - AN EVALUATION USING AN OPEN-SET WORD TEST [J].
CLARK, GM ;
TONG, YC ;
MARTIN, LFA ;
BUSBY, PA .
ACTA OTO-LARYNGOLOGICA, 1981, 91 (3-4) :173-175
[10]   SURGERY FOR THE SAFE INSERTION AND REINSERTION OF THE BANDED ELECTRODE ARRAY [J].
CLARK, GM ;
PYMAN, BC ;
WEBB, RL ;
FRANZ, KHG ;
REDHEAD, TJ ;
SHEPHERD, RK .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1987, 96 (01) :10-12