Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance

被引:73
|
作者
Belov, ME
Zhang, R
Strittmatter, EF
Prior, DC
Tang, K
Smith, RD
机构
[1] Pacific NW Natl Lab, Div Biol Sci, Richland, WA 99352 USA
[2] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1021/ac0206770
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
When combined with capillary LC separations, electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR MS) has demonstrated capabilities for advanced characterization of proteomes based upon analyses of proteolytic digests. Incorporation of external (to the ICR cell) multipole devices with FTICR for ion selection and ion accumulation has enhanced the dynamic range, sensitivity, and duty cycle of measurements. However, the highly variable ion production rate from an LC separation can result in "overfilling" of the external trap during the elution of major peaks and result in m/z discrimination and fragmentation of peptide ions. Excessive space charge trapped in the ICR cell also causes significant shifts in the detected ion cyclotron frequencies, reducing the achievable mass measurement accuracy (MMA) and making protein identification less effective. To eliminate m/z discrimination in the external ion trap, further increase duty cycle, and improve MMA, we have developed the capability for data-dependent adjustment of ion accumulation times in the course of an LC separation, referred to as automated gain control (AGC). This development has been implemented in combination with low kinetic energy gated ion trapping and internal calibration using a dual-channel electrodynamic ion funnel. The overall system was initially evaluated in the analysis of a tryptic digest of bovine serum albumin. In conjunction with internal calibration, the capillary LC-ESI-AGC-FTICR instrumentation provided a similar to10-fold increase in the number of identified tryptic peptides compared to that obtained using a fixed ion accumulation time and external calibration methods.
引用
收藏
页码:4195 / 4205
页数:11
相关论文
共 50 条
  • [1] Initial implementation, of external accumulation liquid chromatography/electrospray ionization Fourier transform ion cyclotron resonance with automated gain control
    Belov, ME
    Rakov, VS
    Nikolaev, EN
    Goshe, MB
    Anderson, GA
    Smith, RD
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (07) : 627 - 636
  • [2] Electrospray ionization-Fourier transform ion cyclotron mass spectrometry using ion preselection and external accumulation for ultrahigh sensitivity
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Auberry, KJ
    Harkewicz, R
    Smith, RD
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (01) : 38 - 48
  • [3] External accumulation of ions for enhanced electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Senko, MW
    Hendrickson, CL
    Emmett, MR
    Shi, SDH
    Marshall, AG
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (09) : 970 - 976
  • [4] Ion Accumulation Time Dependent Molecular Characterization of Natural Organic Matter Using Electrospray Ionization-Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    Cao, Dong
    Lv, Jitao
    Geng, Fanglan
    Rao, Ziyu
    Niu, Hongyun
    Shi, Yali
    Cai, Yaqi
    Kang, Yuehui
    ANALYTICAL CHEMISTRY, 2016, 88 (24) : 12210 - 12218
  • [5] Magnetic field focused ion accumulation for an internal bore liquid chromatography electrospray ionization Fourier transform ion cyclotron resonance mass spectrometer using a central trapping electrode
    Ostrander, CM
    Arkin, CR
    Laude, D
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (06) : 592 - 595
  • [6] Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Hendrickson, CL
    Emmett, MR
    ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1999, 50 : 517 - 536
  • [7] Electrospray ionization Fourier transform ion cyclotron resonance at 9.4 T
    Senko, MW
    Hendrickson, CL
    PasaTolic, L
    Marto, JA
    White, FM
    Guan, SH
    Marshall, AG
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (14) : 1824 - 1828
  • [8] Sheathless electrospray ionization directly from a capillary monolith for fast liquid chromatography coupled to Fourier transform ion cyclotron resonance mass spectrometry
    Leinweber, FC
    Schmid, DG
    Lubda, D
    Sontheimer, B
    Jung, G
    Tallarek, U
    JOURNAL OF MASS SPECTROMETRY, 2004, 39 (02): : 223 - 225
  • [9] The identification of selenopolythionates in aqueous solutions by electrospray ionization-Fourier transform-ion cyclotron resonance-mass spectrometry
    Bothen, Jacob
    Wallschlager, Dirk
    TALANTA, 2021, 223
  • [10] Sequence analysis on biological active peptides using electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometer
    Chen, H
    Xu, JX
    Xin, B
    He, MY
    CHINESE SCIENCE BULLETIN, 2005, 50 (09): : 853 - 857