Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation

被引:24
作者
Gonzalez-Lopez, Felix [1 ]
Bouza-Miguens, Carmen [1 ]
Tejerina, Victor [1 ]
Druchkiv, Vasyl [2 ]
Mompean, Blas [1 ]
Ortega-Usobiaga, Julio [1 ]
Bilbao-Calabuig, Rafael [1 ]
机构
[1] Clin Baviera, Dept Refract Surg, Melchor Fernandez Almagro 9, Madrid 28029, Spain
[2] Clin Baviera, Dept Res & Dev, Valencia, Spain
关键词
Phakic collamer lens; ICL; Pupil; OCT; Central hole; Central port; Posterior chamber phakic lens; INTRAOCULAR-LENS; CENTRAL-HOLE; MYOPIA; EYES;
D O I
10.1186/s40662-021-00262-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens (ICL, STAAR Surgical) with a central port. Methods This prospective, observational single-center case series study comprised 65 eyes from 65 consecutive patients undergoing ICL implant. A modified commercially available swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) device was used for imaging and performing dynamic pupillometry under changing light conditions before and after a mean follow-up interval of four months after surgery. Results Preoperative mean pupil size under photopic conditions was 3.38 +/- 0.64 mm; after surgery, this increased to 3.48 +/- 0.61 mm. Mean pupil size under scotopic light conditions was 5.72 +/- 0.79 mm before surgery and 5.84 +/- 0.77 mm postoperatively. The differences between preoperative and postoperative pupil diameter in miosis and mydriasis were 0.10 +/- 0.44 mm (P = 0.078) and 0.12 +/- 0.58 mm (P = 0.098), respectively. The scotopic pupil exceeded the optic zone of the implanted lens in 39 eyes (60%). The mean central vault value was 412 +/- 177 mu m under maximum miosis and 506 +/- 190 mu m under maximum mydriasis. We found a positive correlation between vault and differences in pupil diameter under all light conditions (P < 0.05). Conclusion Dynamic AS-OCT enables a very precise determination of the pupillary diameter in the iris plane. The changes in the pupil diameter under different light conditions after the implantation of an ICL are related to the postoperative vault.
引用
收藏
页数:8
相关论文
共 23 条
[1]   Five-Year Follow-up of Correction of Myopia: Posterior Chamber Phakic Intraocular Lens With a Central Port Design [J].
Alfonso, Jose F. ;
Fernandez-Vega-Cueto, Luis ;
Alfonso-Bartolozzi, Belen ;
Montes-Mico, Robert ;
Fernandez-Vega, Luis .
JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (03) :169-+
[2]   Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Fernandez-Vega, Luis ;
Almanzar, Dagoberto ;
Perez-Vives, Cari ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (04) :800-805
[3]   Phakic intraocular lens implantation for the correction of hyperopia [J].
Alshamrani, Abdulaziz A. ;
Alharbi, Saad S. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10) :1503-1511
[4]   Colvard pupillometer measurement of scotopic pupil diameter in emmetropes and myopes [J].
Chaidaroon, W ;
Juwattanasomran, W .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2002, 46 (06) :640-644
[5]   Iris and trabecular meshwork pigment changes after posterior chamber phakic intraocular lens implantation [J].
Chun, Yeoun Sook ;
Park, In Ki ;
Lee, Hyeon Il ;
Lee, Jong Ho ;
Kim, Jae Chan .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09) :1452-1458
[6]   Ring-shaped dysphotopsia associated with posterior chamber phakic implantable collamer lenses with a central hole [J].
Eom, Youngsub ;
Kim, Dae Wook ;
Ryu, Dongok ;
Kim, Jun-Heon ;
Yang, Seul Ki ;
Song, Jong Suk ;
Kim, Sug-Whan ;
Kim, Hyo Myung .
ACTA OPHTHALMOLOGICA, 2017, 95 (03) :E170-E178
[7]   Ghost-image analysis in phakic intraocular lenses with central hole as a potential cause of dysphotopsia [J].
Eppig, Timo ;
Spira, Corinna ;
Tsintarakis, Themistoklis ;
El-Husseiny, Moatasem ;
Cayless, Alan ;
Mueller, Marc ;
Seitz, Berthold ;
Langenbucher, Achim .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (11) :2552-2559
[8]  
Gonzalez-Lopez F, 2018, Arch Soc Esp Oftalmol (Engl Ed), V93, P368, DOI 10.1016/j.oftal.2018.04.002
[9]   Long-term assessment of crystalline lens transparency in eyes implanted with a central-hole phakic collamer lens developing low postoperative vault [J].
Gonzalez-Lopez, Felix ;
Bouza-Miguens, Carmen ;
Tejerina, Victor ;
Mompean, Blas ;
Ortega-Usobiaga, Julio ;
Bilbao-Calabuig, Rafael .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (02) :204-210
[10]   Dynamic Assessment of Light-Induced Vaulting Changes of Implantable Collamer Lens With Central Port by Swept-Source OCT: Pilot Study [J].
Gonzalez-Lopez, Felix ;
Mompean, Blas ;
Bilbao-Calabuig, Rafael ;
Vila-Arteaga, Jorge ;
Beltran, Jaime ;
Baviera, Julio .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (03)