Are there advances in the treatment of extracapsular hip fractures in the elderly?

被引:31
作者
Stern, Richard [1 ]
机构
[1] Univ Hosp Geneva, Orthopaed Surg Serv, Geneva, Switzerland
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2007年 / 38卷
关键词
pertrochanteric fracture; sliding compression hip screw; hip intramedullary nail; reverse intertrochanteric fracture;
D O I
10.1016/j.injury.2007.08.015
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
While the rate of failure following hip fracture surgery for extracapsular hip fractures in the elderly is low, an incidence of implant cutout from the femoral head remains regardless of whether fixation is by sliding hip screw or intramedullary nail. In general, a well-executed osteosynthesis is the best assurance of a good outcome with few complications, and typically a less than ideal placement of the implant in the femoral head is the reason for cut-out and failure of the operation. It is clear that there is no difference in the incidence of complications or functional outcome between a sliding hip screw and an intramedullary nail for pertrochanteric fractures (AO/OTA 31-A1 and A2), while the implant of choice in the elderly for the true intertrochanteric fracture (AO/OTA 31-A3; reverse intertrochanteric) is a nail. However, what is less clear is whether there are newer ideas and/or implant designs that represent true advances in the treatment of extracapsular fractures in the elderly. The following review focuses on just this issue.
引用
收藏
页码:77 / 87
页数:11
相关论文
共 80 条
[1]   Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur [J].
Adams, CI ;
Robinson, CM ;
Court-Brown, CM ;
McQueen, MM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (06) :394-400
[2]  
[Anonymous], CLIN ORTHOP
[3]  
APEL DM, 1989, CLIN ORTHOP RELAT R, V246, P156
[4]   Implant-related complications in the treatment of unstable intertrochanteric fractures:: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices [J].
Audigé, L ;
Hanson, B ;
Swiontkowski, MF .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (04) :197-203
[5]   Clinical results using the trochanter stabilizing plate (TSP): The modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures [J].
Babst, R ;
Renner, N ;
Biedermann, M ;
Rosso, R ;
Heberer, M ;
Harder, F ;
Regazzoni, P .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (06) :392-399
[6]  
Baixauli F, 1999, CLIN ORTHOP RELAT R, P205
[7]   THE EFFECT OF ADJUNCTIVE METHYLMETHACRYLATE ON FAILURES OF FIXATION AND FUNCTION IN PATIENTS WITH INTERTROCHANTERIC FRACTURES AND OSTEOPOROSIS [J].
BARTUCCI, EJ ;
GONZALEZ, MH ;
COOPERMAN, DR ;
FREEDBERG, HI ;
BARMADA, R ;
LAROS, GS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1094-1107
[8]   THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[9]   Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip [J].
Baumgaertner, MR ;
Solberg, BD .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06) :969-971
[10]  
Bess R J, 1997, J South Orthop Assoc, V6, P173