Inter- and Intra-rater Agreement of Dermatologic Ultrasound for the Diagnosis of Lobular and Septal Panniculitis

被引:14
|
作者
Romani, Jorge [1 ]
Giavedoni, Priscila [2 ]
Roe, Esther [3 ]
Vidal, David [4 ]
Luelmo, Jesus [1 ]
Wortsman, Ximena [5 ,6 ]
机构
[1] Hosp Parc Tauli, Dept Dermatol, Barcelona, Spain
[2] Hosp Clin I Prov, Dept Dermatol, Barcelona, Spain
[3] Hosp Santa Creu & Sant Pau, Dept Dermatol, Barcelona, Spain
[4] Hosp Moises Broggi, Dept Dermatol, Barcelona, Spain
[5] Univ Chile, Fac Med, Inst Diagnost Imaging & Res Skin & Soft Tissues, Dept Dermatol, Santiago, Chile
[6] Pontificia Univ Catolica Chile, Santiago, Chile
关键词
dermatologic ultrasound; lobular; panniculitis; septal; ultrasound;
D O I
10.1002/jum.15080
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-Dermatologic ultrasound (US) may aid in the diagnosis and classification of panniculitis. The purpose of this study was to assess the capability of dermatologic US for subtyping mainly septal/lobular panniculitis. Methods-A multicentric and prospective study of the inter- and intra-rater agreement of dermatologic US for subtyping panniculitis was conducted among 4 clinicians with experience in dermatologic US and a radiologist specialized in dermatologic US. Clinicians recruited patients and performed dermatologic US examinations of the most substantial lesion and punch biopsies. A histologic study was considered the reference standard. Then the images were blindly evaluated by all researchers. For intra- and inter-rater agreement, Cohen and Fleiss kappa values were calculated. Results-Sixty-four patients were included. The Cohen intra-rater kappa was 0.74. Sensitivity and specificity for lobular panniculitis were 85.19 and 88.57, respectively. The Fleiss inter-rater kappa was 0.47. Limitations of the study included the small number of patients and differences in evaluators and their dermatologic US equipment. Conclusions-This study supports the use of US for diagnosing panniculitis. For subtyping panniculitis, the intra-rater correlation was good. Improvement of inter-rater agreement may depend on access to clinical information, dynamic images, a better definition of criteria, homogeneous configurations of the devices, and the expertise of dermatologic US operators.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 25 条
  • [1] Ultrasound imaging in patients with hip pain and suspected hip osteoarthritis: an inter-rater and intra-rater reliability study
    Clausen, Stine
    Kjaer, Soren
    Fredberg, Ulrich
    Terslev, Lene
    Hartvigsen, Jan
    Arnbak, Bodil
    BMJ OPEN, 2020, 10 (11):
  • [2] Novel Ultrasound Anatomical Measurement of the Deep Transverse Metatarsal Ligament: An Intra-Rater Reliability and Inter-Rater Concordance Study
    del Mar Ruiz-Herrera, Maria
    Marcos-Tejedor, Felix
    Aldana-Caballero, Alberto
    Calvo-Lobo, Cesar
    Rodriguez-Sanz, David
    Moroni, Simone
    Konschake, Marko
    Mohedano-Moriano, Alicia
    Aceituno-Gomez, Javier
    Criado-alvarez, Juan Jose
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (09)
  • [3] Intra- and inter-rater reliability of ultrasound measures of the anterior cruciate ligament
    Sievert, Zachary A.
    Bennett, Hunter J.
    Weinhandl, Joshua T.
    JOURNAL OF ULTRASOUND, 2021, 24 (01) : 49 - 55
  • [4] Intra- and inter-rater reliability of ultrasound measures of the anterior cruciate ligament
    Zachary A. Sievert
    Hunter J. Bennett
    Joshua T. Weinhandl
    Journal of Ultrasound, 2021, 24 : 49 - 55
  • [5] Inter- and intra-observer reproducibility of ultrasound analysis of the long head of the biceps
    Mazaleyrat, Matthieu
    Barthelemy, Raphael
    Bouilleau, Loic
    Charousset, Christophe
    Berhouet, Julien
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (02) : 235 - 239
  • [6] Inter-rater agreement in the diagnosis of adenomyosis by 2-and 3-dimensional transvaginal ultrasonography
    Rasmussen, Christina K.
    Hansen, Estrid S.
    Dueholm, Margit
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (03) : 657 - 665
  • [7] Intra- and Inter-Rater Agreement Describing Myometrial Lesions Using Morphologic Uterus Sonographic Assessment: A Pilot Study
    Rasmussen, Christina Kjaergaard
    Van den Bosch, Thierry
    Exacoustos, Caterina
    Manegold-Brauer, Gwendolin
    Benacerraf, Beryl R.
    Froyman, Wouter
    Landolfo, Chiara
    Condorelli, Margherita
    Egekvist, Anne G.
    Josefsson, Hampus
    Leone, Francesco Paolo Giuseppe
    Jokubkiene, Ligita
    Zannoni, Letizia
    Epstein, Elisabeth
    Installe, Arnaud
    Dueholm, Margit
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (10) : 2673 - 2683
  • [8] A Novel Method for the Measurement of the Vaginal Wall Thickness by Transvaginal Ultrasound: A Study of Inter- and Intra-Observer Reliability
    Bosio, Sara
    Barba, Marta
    Vigna, Annalisa
    Cola, Alice
    De Vicari, Desiree
    Costa, Clarissa
    Volonte, Silvia
    Frigerio, Matteo
    MEDICINA-LITHUANIA, 2024, 60 (03):
  • [9] Six of one, half a dozen of the other: A measure of multidisciplinary inter/intra-rater reliability of the society for fetal urology and urinary tract dilation grading systems for hydronephrosis
    Rickard, Mandy
    Easterbrook, Bethany
    Kim, Soojin
    Farrokhyar, Forough
    Stein, Nina
    Arora, Steven
    Belostotsky, Vladamir
    DeMaria, Jorge
    Lorenzo, Armando J.
    Braga, Luis H.
    JOURNAL OF PEDIATRIC UROLOGY, 2017, 13 (01) : 80.e1 - 80.e5
  • [10] Intra-rater reliability of transversus abdominis measurement by a novice examiner: Comparison of "freehand" to "probe force device" method of real-time ultrasound imaging
    Kennedy, Vanessa L.
    Flavell, Carol A.
    Doma, Kenji
    ULTRASOUND, 2019, 27 (03) : 156 - 166