共 30 条
Clinical high-resolution mapping of the proteoglycan-bound water fraction in articular cartilage of the human knee joint
被引:7
作者:
Bouhrara, Mustapha
[1
]
Reiter, David A.
[1
]
Sexton, Kyle W.
[1
]
Bergeron, Christopher M.
[1
]
Zukley, Linda M.
[2
]
Spencer, Richard G.
[1
]
机构:
[1] NIA, Clin Invest Lab, NIH, Baltimore, MD 21224 USA
[2] NIA, Clin Res Core, Off Sci Director, NIH, Baltimore, MD 21225 USA
基金:
美国国家卫生研究院;
关键词:
Magnetic resonance imaging;
Proteoglycan water fraction;
Knee cartilage;
MULTICOMPONENT T2 ANALYSIS;
TRANSVERSE RELAXATION;
BAYESIAN-ANALYSIS;
HUMAN BRAIN;
T-2;
MCDESPOT;
SSFP;
STABILITY;
ACCURACY;
SEQUENCE;
D O I:
10.1016/j.mri.2017.06.011
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: We applied our recently introduced Bayesian analytic method to achieve clinically-feasible in-vivo mapping of the proteoglycan water fraction (PgWF) of human knee cartilage with improved spatial resolution and stability as compared to existing methods. Materials and methods: Multicomponent driven equilibrium single-pulse observation of T-1 and T-2 (mcDESPOT) datasets were acquired from the knees of two healthy young subjects and one older subject with previous knee injury. Each dataset was processed using Bayesian Monte Carlo (BMC) analysis incorporating a two-component tissue model. We assessed the performance and reproducibility of BMC and of the conventional analysis of stochastic region contraction (SRC) in the estimation of PgWF. Stability of the BMC analysis of PgWF was tested by comparing independent high-resolution (HR) datasets from each of the two young subjects. Results: Unlike SRC, the BMC-derived maps from the two HR datasets were essentially identical. Furthermore, SRC maps showed substantial random variation in estimated PgWF, and mean values that differed from those obtained using BMC. In addition, PgWF maps derived from conventional low-resolution (LR) datasets exhibited partial volume and magnetic susceptibility effects. These artifacts were absent in HR PgWF images. Finally, our analysis showed regional variation in PgWF estimates, and substantially higher values in the younger subjects as compared to the older subject. Conclusions: BMC-mcDESPOT permits HR in-vivo mapping of PgWF in human knee cartilage in a clinically-feasible acquisition time. HR mapping reduces the impact of partial volume and magnetic susceptibility artifacts compared to LR mapping. Finally, BMC-mcDESPOT demonstrated excellent reproducibility in the determination of PgWF. Published by Elsevier Inc.
引用
收藏
页码:1 / 5
页数:5
相关论文