Retinal nerve fibre layer thickness in full-term children assessed with Heidelberg retinal tomography and optical coherence tomography: normal values and interocular asymmetry

被引:23
|
作者
Larsson, Eva [1 ]
Eriksson, Urban [1 ]
Alm, Albert [1 ]
机构
[1] Univ Uppsala Hosp, Dept Ophthalmol, S-75185 Uppsala, Sweden
关键词
children; full-term; Heidelberg retinal tomography; interocular asymmetry; normal values; optical coherence tomography; repeatability; retinal nerve fibre layer; MACULAR THICKNESS; GLAUCOMATOUS EYES; DISC; AGE; PARAMETERS; AGREEMENT;
D O I
10.1111/j.1755-3768.2009.01680.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This study aimed to investigate normal values and interocular differences in retinal nerve fibre layer (RNFL) thickness, using optical coherence tomography (OCT) and Heidelberg retinal tomography (HRT), in 5-16-year-old children born at full-term with normal birthweights. Methods: Fifty-six children with normal visual acuity and refraction were examined with Stratus OCT and HRT. Three examinations were performed in each eye. One eye in each child was randomized for analyses of normal values. Findings in 54 eyes were evaluated. Mean values of RNFL thickness were calculated. Coefficients of variance and intraclass correlations were calculated. The correlation between right and left eyes and the limits of difference were determined for both methods. Results: Mean RNFL thickness was 98.4 mu m (standard deviation [SD] 7.88 mu m) assessed with OCT and 213.0 mu m (SD 54.0 mu m) assessed with HRT. No correlations between age or gender and RNFL thickness were found. The coefficients of variance were 2.9% and 5.6% for OCT and HRT, respectively, and intraclass correlations were 0.85 and 0.88, respectively. The limits of difference between the two eyes ranged from -9 mu m to 9 mu m with OCT and from -109 mu m to 87 mu m with HRT. Conclusions: Both OCT and HRT can be used in children aged 5-16 years, but OCT provides less variability in determinations of RNFL thickness, both in repeated examinations of the same eye and in comparisons between the two eyes. The present study provides values for normal RNFL thickness in healthy children which can be used to make comparisons with values in children with optic nerve diseases.
引用
收藏
页码:151 / 158
页数:8
相关论文
共 50 条
  • [41] Evaluation of Peripapillary Retinal Nerve Fiber Layer Thickness in Myopic Eyes by Spectral-domain Optical Coherence Tomography
    Salih, Payman A-K. Mohammad
    JOURNAL OF GLAUCOMA, 2012, 21 (01) : 41 - 44
  • [42] An analysis of normal variations in retinal nerve fiber layer thickness profiles measured with optical coherence tomography
    Ghadiali, Quraish
    Hood, Donald C.
    Lee, Clara
    Manns, Jack
    Llinas, Alex
    Grover, Larissa K.
    Greenstein, Vivienne C.
    Liebmann, Jeffrey M.
    Odel, Jeffrey G.
    Ritch, Robert
    JOURNAL OF GLAUCOMA, 2008, 17 (05) : 333 - 340
  • [43] Evaluation of the effect of aging on retinal nerve fiber layer thickness measured by optical coherence tomography
    Kanamori, A
    Escano, MFT
    Eno, A
    Nakamura, M
    Maeda, H
    Seya, R
    Ishibashi, K
    Negi, A
    OPHTHALMOLOGICA, 2003, 217 (04) : 273 - 278
  • [44] Study of retinal nerve fiber layer thickness in diabetic patients using optical coherence tomography
    Bhaskaran, Aparna
    Babu, Mahesh
    Sudhakar, N. A.
    Kudlu, Krishna Prasad
    Shashidhara, B. C.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (03) : 920 - 926
  • [45] Retinal nerve fiber layer thickness in a healthy Turkish population measured by optical coherence tomography
    Cubuk, Mehmet
    Sahinoglu-Keskek, Nedime
    Keskek, Sakir Ozgur
    ANNALS OF SAUDI MEDICINE, 2016, 36 (06) : 409 - 413
  • [46] Agreement Between Standard Optical Coherence Tomography and Optical Coherence Tomography-Based Angiography in Estimating Retinal Nerve Fiber Layer Thickness
    Yilmaz, Hayati
    Koylu, Mehmet Talay
    Yilmaz, Alper Can
    Durukan, Ali Hakan
    Uysal, Yusuf
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2020, 50 (05): : 264 - 270
  • [47] Repeatability of Peripapillary Retinal Nerve Fiber Layer and Inner Retinal Thickness Among Two Spectral Domain Optical Coherence Tomography Devices
    Matlach, Juliane
    Wagner, Martin
    Malzahn, Uwe
    Goebel, Winfried
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (10) : 6536 - 6546
  • [48] Segmentation error in spectral domain optical coherence tomography measures of the retinal nerve fibre layer thickness in idiopathic intracranial hypertension
    Anuriti Aojula
    Susan P Mollan
    John Horsburgh
    Andreas Yiangou
    Kiera A Markey
    James L Mitchell
    William J Scotton
    Pearse A Keane
    Alexandra J Sinclair
    BMC Ophthalmology, 17
  • [49] Assessment of Macula and Retinal Nerve Fiber Layer Thickness with Optical Coherence Tomography in Myopia
    Ozkagnici, Ahmet
    Tokgoz, Mine
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2012, 32 (02): : 415 - 427
  • [50] Interocular symmetry of retinal nerve fiber layer and optic nerve head parameters measured by Cirrus high-definition optical coherence tomography in a normal pediatric population
    Pawar, Neelam
    Maheshwari, Devendra
    Ravindran, Meenakshi
    Ramakrishnan, Renagappa
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (10) : 955 - 962